![FarmTek Growers Supply HydroCycle Vertical Aeroponic Systems Important Information Manual Download Page 17](http://html.mh-extra.com/html/farmtek/growers-supply-hydrocycle-vertical-aeroponic-systems/growers-supply-hydrocycle-vertical-aeroponic-systems_important-information-manual_545409017.webp)
17
Revision date: 09.21.18
113593
OPERATIONAL AND MAINTENANCE INFORMATION
Clean filters ensure proper flow. Filters should also be cleaned after cleaning
reservoir to remove sediment. When a reduced flow rate or drop in pressure is
noticed, follow these steps to clean filters and filter housings.
ATTENTION:
SYSTEM SHOWN DIFFERS FROM ACTUAL SYSTEM.
FILTER ASSEMBLY IS THE SAME. STEPS FOR CLEANING THE
FILTER ARE THE SAME.
Clean Filter Screen and Housing
1. Turn off pump. Open valve on
filter to drain supply line and
filter.
2. Grip filter housing and main
supply line and remove
housing. Do not apply force
to filter or supply line fittings.
Hold these steady when
disassembling filter.
3. Remove screen from housing.
Using clean water, rinse
housing and screen.
4. Insert screen into housing,
reassemble filter, and
close
valve.
5. Turn on pump. Prime if
needed.
6. Check filter for leaks.
Flow
Flow