![FARMSCAN 7000 Series Operator'S Manual Download Page 45](http://html.mh-extra.com/html/farmscan/7000-series/7000-series_operators-manual_545376045.webp)
March 2020
www.farmscan.com.au
AM-7500-5
44
Tank Setup
TEST (5)
The output test allows the user to check the metering control and voltage settings are working correctly.
This will allow the metering or control valve to open and allow feedback from the sensors.
To test the output of a Tank, follow these steps:
1.
Select the green
Bin
/
Tank 1
button to enable it.
WARNING: This will turn on the tank output immediately.
2.
Adjust the
Output % (by +1%)
to give the output you desire.
a.
Does the metering drive turn?
b.
Continue to up the percentage until the metering drive is turning slowly
c.
You will be displayed with X voltage & X % values.
d.
These values will be close to the auto calibrated figures
3.
Select the red
Bin
/
Tank 1
button to disable it.
4.
Select the green
Tick
button to exit the test screen.
THE TEST SCREEN CAN ALSO BE USED TO FIND THE MIN AND MAXIMUM VALUES OF THE METERING
DRIVE. BY ADJUSTING THE PERCETAGE VALUES YOU CAN FIND THE MIN/MAX VOLTAGES REQUIRED TO
MOVE THE METERING DRIVE. SIMPLY COPY THESE SETTINGS IN THE MIN/MAX SETTINGS DURING THE
PREVIOUS SETUPS.