2.1 Serial port connection
Before connecting the the ECU Dataseed
CONTROLLER
cable to G7 Dataseed, make sure both
devices are switched off. No other settings are necessary.
2.2 Connection to hydraulic electro valves
Before connecting the RIGHT and LEFT connection cables to the implement, make sure ECU Dataseed
is switched off.
WARNING:
The shifting mechanism could move suddenly and cause severe injury or death.
ECU Dataseed can control the coils of the electro-hydraulic valves which are under these limits:
●
Nominal voltage: 12V DC
●
Max current: 3.15A (each coil)
2.3 Power supply connection
The connection of the power cable to the battery must be done carefully. Please refer to a professional
technician. The following instructions shall be considered:
●
The positive (red wire) must be under switch
●
The negative (black wire) must be connected to a clear and pure negative. Do not connect the negative
pole to oxidized or painted metallic parts
●
The power supply must be able to provide at least 10A (in case of RIGHT and LEFT only). Do not
connect the device to weak or unstable sources
●
Do not connect the positive (red wire) to the starter motor
●
Do not route the wires near the starter motor or near any other magnetic source
ATTENTION:
power off the device when it is not used.
3. LED Status
Color
Status
Detail
Blue solid
Automatic mode
Communication with G7 Dataseed is stable.
The actuators connected to RIGHT and LEFT are moving in automatic mode.
Green solid Manual mode
Communication with G7 Dataseed is stable.
The actuators connected to RIGHT and LEFT can be moved in manual mode.
Pink blinking Communication error Communication with G7 Dataseed is not established.