background image

2.1 Serial port connection

Before connecting the the ECU Dataseed 

CONTROLLER

 cable to G7 Dataseed, make sure both 

devices are switched off. No other settings are necessary.

2.2 Connection to hydraulic electro valves

Before connecting the RIGHT and LEFT connection cables to the implement, make sure ECU Dataseed 

is switched off.

WARNING:

 The shifting mechanism could move suddenly and cause severe injury or death.

ECU Dataseed can control the coils of the electro-hydraulic valves which are under these limits:

 

Nominal voltage: 12V DC

 

Max current: 3.15A (each coil)

2.3 Power supply connection

The connection of the power cable to the battery must be done carefully. Please refer to a professional 

technician. The following instructions shall be considered:

 

The positive (red wire) must be under switch

 

The negative (black wire) must be connected to a clear and pure negative. Do not connect the negative 

pole to oxidized or painted metallic parts

 

The power supply must be able to provide at least 10A (in case of RIGHT and LEFT only). Do not 

connect the device to weak or unstable sources

 

Do not connect the positive (red wire) to the starter motor

 

Do not route the wires near the starter motor or near any other magnetic source

ATTENTION: 

power off the device when it is not used.

3. LED Status

Color

Status

Detail

Blue solid

Automatic mode

Communication with G7 Dataseed is stable.
The actuators connected to RIGHT and LEFT are moving in automatic mode.

Green solid Manual mode

Communication with G7 Dataseed is stable.
The actuators connected to RIGHT and LEFT can be moved in manual mode.

Pink blinking Communication error Communication with G7 Dataseed is not established. 

Reviews: