ANNUAL INSPECTION RECORD
ITEM UNDER INSPECTION
ANNUAL INSPECTION
F
R
NOTES
CLEANLINESS OF LIFTING BOOM
WELDED JOINTS OF LIFTING BOOM
WELDED JOINTS OF FOLDING BOOMS
WELDED JOINTS OF COLUMN
FASTENING OF ROTATOR
STATE OF BRACKETS
BACKLASH OF ROTATING DEVICE
STATE OF SWIVEL AXIS BEARINGS
STATE OF LIFTING BOOM BEARINGS
STATE OF FOLDING BOOM BEARINGS
STATE OF JOINT PINS
LOCKING OF JOINT PINS
STATE OF CONTROLS
STATE OF CYLINDERS
STATE OF CYLINDER GASKETS
STATE OF PISTON RODS
STATE OF HYDRAULIC HOSES
STATE OF HYDRAULIC HOSE
STATE OF HYDRAULIC CONNECTORS
PROTECTION OF REGULATING VALVE LEVERS
TIGHTNESS OF LOADER’S FASTENING
OPERATION, MAINTENANCE AND
INSPECTION MANUAL
STATE OF SAFETY DISTANCE TABLE
STATE OF LOAD SIGN
STATE OF MACHINE PLATE
HAS INSTALLATION INSPECTION BEEN
CARRIED OUT?
PRESSURE RELIEF VALVE _______ bar
PROTECTION VALVES _______ bar
STATE OF STRUCTURES AFTER MAX.
ALLOWABLE TEST LOAD
SAGGING OF BOOMS, MAX. RANGE OF 60 cm
STATE OF SLIDE PLATES, MAX. GAP OF 8 mm
F = faultless R = needs repair
Inspector:
Date
and
place: