C
HECKING THE ACCUMULATOR PRESSURE
•
A proper pressure is required for the proper protection function.
•
In case of a pressure loss in the accumulator, the release force quickly increases, the protection is
overloaded, which may lead to its damage.
•
A pressure too high on the pressure gauges during release indicates a low pressure in the accumulator.
•
Contact the Service in case of problems with the pressure accumulators.
•
Check the pressure when the hydraulic system is depressurized; the pressure on the pressure gauge is
zero.
•
Only professionally trained staff may inspect the accumulator pressure and special equipment is
required
.
PRESSURE VESSEL
•
Never open or adjust (welding, drilling etc.) the
pressure vessel (pressure accumulator). The
pressure vessel is still under gas pressure even
after it has been emptied.
•
Empty the pressure vessel in case of any work
on the hydraulics of the machine. The
manometer must not show any pressure, or the
pressure on the manometer must decrease to 0
bars. Only then it is permitted to work on the
hydraulic circuit.
Chisel accumulators