Picture. 9 - Diagram of the hydraulic drive of the fan
1.
Hydraulic motor
2.
Pressure hose
3.
Outlet hose
4.
Measuring point
5.
Free drain to the tractor tank
6.
Tractor distributor
Warning!
Farmet a.s. is not liable for any damage of the hydraulic drive or the tractor caused by improper connection of
the hydraulic drive.
7.
ELECTRONIC SYSTEM OF THE MACHINE
General Instructions for Use:
-
Install the feeding cable (included in the delivery) in the tractor system prior to the connection of the
electronic system
-
The cable must be connected directly to the tractor accumulator
-
The connection of the cable to the accumulator must be fixed and with a good contact – otherwise there
may be system failures and improper function
-
The cable must not be connected to any other connectors of the tractor!
-
Pay attention to proper poling (
black -
,
red +
)
-
The cable is equipped with two circuit fuses – 50A, 15A and 1A fuse for the terminal
-
Use only the delivered cable to connect the electronic system
-
The voltage in the accumulator must be within the range from 12 V to 14.4 V to ensure proper function
of the system
-
Secure the connecting cables between the machine and tractor against mechanical damage and against
heat stress from the hot parts of the tractor and hydraulic conduction
-
Turn on the display after you have connected the system to the power source
-
If an unusual situation occurs during the operation, disconnect the whole system from the power source
for a short time
-
Only connect and disconnect all the modules of the control system when the system is disconnected from
the power supply
-
Turn on the system after you have started the tractor motor (do not start the motor with the system on)
-
If the current fuse blows, first find the cause of the defect or seek professional service
-
Do not replace the current fuse with another item
-
Some parts of the system may heat up to the temperature of 50°C during operation. If the temperature
is higher, look for the cause or seek professional service
-
Protect the display from water and temperatures below -20°C and above +60°C
-
If you have to perform welding on the machine or the tractor, disconnect the unit from the power source
and disconnect the connecting cables
TRACTOR
SOWING
MACHINE
5
3
1
4
2
6
Summary of Contents for FALCON 3
Page 6: ...Manual FALCON 3 4 6 8 6 99 ...
Page 20: ...Manual FALCON 3 4 6 8 20 99 6 3 HYDRAULIC DIAGRAM OF THE MACHINE ...
Page 77: ...Manual FALCON 3 4 6 8 77 99 ISO alarms ...
Page 78: ...Manual FALCON 3 4 6 8 78 99 Hydraulic alarms Regulation alarms ...
Page 79: ...Manual FALCON 3 4 6 8 79 99 ...
Page 80: ...Manual FALCON 3 4 6 8 80 99 Machine specific alarms ...
Page 81: ...Manual FALCON 3 4 6 8 81 99 ...
Page 82: ...Manual FALCON 3 4 6 8 82 99 ...
Page 83: ...Manual FALCON 3 4 6 8 83 99 ...