Assemble the earth stake stand as illustrated above. Push earth stake firmly to 
the ground. Make sure it doesn't fall. 
If soil is dry, the included earth stake stand may not provide sufficient earthing. 
In this case use separate Olli earth rods. 

Fence connection

Connect black earth wire to terminal 

marked with the earth symbol 

Connect red fence connect wire to 
terminal marked with a lightning 

symbol  and to the fence wire. 

Batteries 

Energiser may be supplied from a 12 V rechargeable lead acid battery or from 
four non-rechargeable 1.5 V alkaline size D batteries (type LR20). If both are 
installed, the 12 V battery will be used.  

Rechargeable 12 V lead acid battery: 

Connect battery cord red clamp to 

positive (+) battery pole and black clamp to negative (-) battery pole.

 

Non-rechargeable alkaline batteries: 

- Remove battery holder by squeezing its handle and pull it out.
- Insert four batteries in correct polarity as shown on the battery holder.
- Firmly push battery holder back into the energiser so that it locks in place.

Do not touch the fence with the battery cord: the energiser 
could be damaged! When using the energiser without a 12 V 
battery, connect both battery cord clamps to the earth stake 

stand instead of leaving them on the ground. 

Mains Adapter (optional accessory for 122B / 62B) 

The mains adapter may be used to supply 
the energiser and to recharge the 12 V 
battery. During a power outage, energiser 
will continue to operate from the 12 V 

Summary of Contents for OLLI 122B

Page 1: ...ELECTRIC FENCE ENERGISERS 122B 62B 42B EN Operating Manual ...

Page 2: ...entilated area during charging Do not handle fire near the battery Discard leaking batteries with care Recycle used batteries according to your local regulations All Olli energisers fulfill the safety regulations that are defined for fence energisers The electric shock given by the fence is painful and may present an danger for small children or persons suffering from heart problems if they get tr...

Page 3: ...ravels through the animal to earth and back to the energiser through the earth stakes Preparation for Use Never install the energiser upside down or leave it on the ground The energiser must be screw mounted on a wall or a post or to included earth stake stand Earth Stake Stand Assembly ...

Page 4: ...ill be used Rechargeable 12 V lead acid battery Connect battery cord red clamp to positive battery pole and black clamp to negative battery pole Non rechargeable alkaline batteries Remove battery holder by squeezing its handle and pull it out Insert four batteries in correct polarity as shown on the battery holder Firmly push battery holder back into the energiser so that it locks in place Do not ...

Page 5: ...nnect Olli solar panel to the charging port on the bottom of the energiser Note the energiser needs to be switched on before battery charging starts Once charging has started the energiser can be switched off The adapter solar light will shine if mains adapter or solar panel is connected even when not charging Battery life depends on power setting capacity of batteries and temperature and for mode...

Page 6: ...on and keep it pressed for 3 seconds until the unit beeps twice on shutdown Olli 122B 62B Features Full power Low power Pulse light Battery warning light Power button Pulse light Battery warning light Mains adapter or solar panel connected Power button Full power Low power Day mode Full power during the day Low at night Night mode Full power at night Low during the day Power mode select button ...

Page 7: ...ction is active operating with low power and slow pulse rate Recharge the battery Battery Warning Light on Alkaline Battery Operation When neither 12 V battery nor mains adapter are connected the battery warning light indicates voltage of the alkaline batteries after each fence pulse No light Battery voltage One flash Buy new alkaline batteries Two flashes Change the alkaline batteries Three flash...

Page 8: ...ne earth stake Extra earth stakes should be 1 m from each other and connected together with electrical wire How to Test Earthing 1 Make a fence fault by connecting fence wire to ground with metal rods 2 Push fence tester earth rod into the ground 3 Touch the earth stake with the metal tip of the tester If tester reads over 400 Volts add more earth stakes 1 m apart from each other and connect them ...

Page 9: ...or if lightning occurs frequently in the region It is also advisable to disconnect both the fence and mains power from the energiser if you leave your electric fence unused for a long period of time Warranty This product carries a three 3 year manufacturer s warranty for materials and workmanship and lightning induced damage from the date it was retailed To claim the warranty the customer should r...

Page 10: ...f the Manufacturer Olli does not accept any responsibility for any direct indirect or consequential damages that are caused by the use of the product or the fact that the product could not be used The liability of Olli is limited to the price of the product in maximum Only the manufacturer and its authorised service partners are allowed to open up or repair the energiser Danger of electrical shock...

Page 11: ... least 2 5 m If this gap is to be closed this shall be affected by means of electrically nonconductive material or an isolated metal barrier Barbed wire or razor wire MUST NOT be electrified by an energiser A distance of at least 10 m shall be maintained between the energiser earth electrode and any other earthing system connected parts such as the power supply system protective earth or the telec...

Page 12: ...at point or a crossing by means of stiles shall be provided At any such crossing the adjacent electrified wires shall carry warning signs Ensure that all mains operated ancillary equipment connected to the electric animal fence circuit provide a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energiser clauses 14 16 and 29 of the standard IEC 6...

Page 13: ... 2010 Tuusula Finland February 31th 2014 Signed Declaration of Conformity documents are filed at Farmcomp Oy Tuusula Olli Specifications 122B 62B 42B Maximum fence voltage 8500 V 8500V 9100V Fence voltage at 500 Ω load 3880 V 2960V 2800V Charged energy 1 63 J 0 82 J 0 43 J Maximum output energy 1 21 J 0 60 J 0 34 J Current consumption fast speed 12 V battery full power low power 69 109 mA 46 mA 40...

Page 14: ...FARMCOMP OY Jusslansuora 8 FI 04360 TUUSULA FINLAND Tel 358 9 7744 970 info farmcomp fi www olli fi Copyright Farmcomp Oy 2014 All Rights Reserved 3820779 ...