![Farmcomp FARMEX HT-PRO Operating Instructions Manual Download Page 3](http://html.mh-extra.com/html/farmcomp/farmex-ht-pro/farmex-ht-pro_operating-instructions-manual_545250003.webp)
EN
Centigrade.
NOTE:
If both switches are pressed simultaneously, the tester
will not be harmed, but only a meaningless number will be
displayed.
1.5 To turn backlighting display option on or off
, press the
button above the “Light Bulb” symbol at the same time
something – anything – is being displayed. Your HT-PRO™ will
retain its backlighting mode (on or off) until changed by the
operator (even if the battery is removed).
2. OPERATING NOTES
1.
Moisture readings
below 8.0%
will be displayed as
“00.0”
. Readings
above 45.0%
will be displayed as
“99.9”.
Temperature readings below 0˚C (32˚F) will be
displayed as 00.0. Readings above 99˚C (225˚F) will be
displayed as “99.9”.
2.
The HT-PRO™ will display “00.0” in open air. (If open air
reading of 8.0 is displayed, the tip probably needs
cleaning. Clean tip and recalibrate tester.)
3.
Temperatures can be measured from 0˚ to 99˚C (32˚ to
225˚F). Make sure to allow the tip of the probe to adjust
to the bale temperature. This can take a minute or two.
4.
The tester measures only the hay in contact with the
tip of the probe. Because moisture may vary widely in
different parts of the windrow, it will vary within each
bale.
Take readings in at least five (5) places in the
bale, and use the HIGHEST reading as a guideline.
5.
Consult your local experts for recommended baling
moisture.
6.
Your tester is for reading moisture in hay. Placing a
probe in 100% moisture – water– will NOT result in a
reading of 100%.