APPLIANCE PLACEMENT
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the
requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48” of the front of the appliance.
CLEARANCE TO COMBUSTIBLES
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (CEILING OF
ENCLOSURE TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT).
PARALLEL & CORNER
SINGLE WALL CONNECTOR
DOUBLE WALL CONNECTOR
Lava
Lava
SIDEWALL (A)
SIDEWALL TO FLUE (B)
BACKWALL (C)
BACKWALL TO FLUE (D)
CORNER (E)
CEILING (F)
84”
84”
FLOOR PROTECTOR
SIZE (MIN)
37" x 44"
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.