INSTALLATION INSTRUCTION
NOTE: Floor-Ember protection is required for spark and ash shielding, not for limiting
floor temperatures from the radiant heat of the appliance.
1. Proper clearances must be maintained for adequate air circulation. Adequate ventilation
must be provided while operating this stove.
2. The stove must be placed on solid masonry, solid concrete, or when installing on combus-
tible floor, floor must be protected by insulating plate ( steel, brass, marble, stone, ceramic
tiles, etc.) or on UL1618 listed floor protector. The base must extend at least 18" (46 cm)
beyond the front of the stove and 8"(20 cm) to the sides, and MUST extend under the stove
pipe. (Check local building codes and fire protection ordinances.) Floor protector minimum
size; 37"W x 44"D
3. The stove must have its own flue. DO NOT CONNECT THIS UNIT TO A CHIMNEY
SERVING OTHER APPLIANCES.
4. Connect flue collar to the stove and adapter . The crimped end of the stove pipe must be in-
stalled facing down to fit inside the adapter. Figure 1, page
5. Use three (3) sheet metal screws at each joint of stove pipe and adapter to firmly hold stove
pipe together. Use 6" round black/blue stove pipe (Listed to UL 103, Type HT and evaluat-
ed to CAN/ULC-S629-M87) NOT galvanized pipe. DO NOT CONNECT THIS STOVE
TO ANY AIR DISTRIBUTUIN OR DUCT SYSTEM.
6. Slope any horizontal stove pipe upward toward the chimney at least 1/4 inch for each foot
of horizontal run.
7. You must have at least 18" of clearance between any horizontal pipe and ceiling. 8.
The stove pipe must NOT extend to far into the chimney flue.
9. It is recommended that no more than two (2) 90 degree bends be used in the stove pipe in-
stallation.
10. Connect to 6" inspected masonry chimney or 6" UL Type HT listed chimney.
A PROFESSIONAL, LICENSED HEATHING AND COOLING CONTRACTOR SHOULD
BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF
THIS SOLID FUEL BURNING APPLIANCE.
MASONRY CHIMNEY
Before using an existing masonry chimney, clean the chimney, inspect the flue liner and make
any repair needed to be sure it is safe to use.
If connector stove pipe must go through a combustible wall before entering the masonry chim-
ney, consult a qualified mason or chimney dealer. The installation must conform to local fire
codes, and NFPA 211.
Do NOT connect this stove into the same chimney flue as the fireplace or flue from another
stove. If there is a cleanout opening in the base of the chimney, close it tightly.
UL LISTED CHIMNEY
Carefully follow chimney manufacturer's instructions. Us only a UL 103 Type HT Listed Resi-
dential Type and Building Heating Appliance Chimney. The top of the chimney must be at least
three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within
ten (10) feet.