background image

- 2 -

INSTALLATION DIAGRAMS

-

The cables, which are heavily outlined, have a minimum section of 0.75mm² (AWG18).

127V

0

230V

110-127Vac

220-230Vac

127V

0

230V

PRS210ED

VERY IMPORTANT

To comply with the European Standards on Electromagnetic Compat-
ibility and to increase the reliability of the product, it is necessary to
connect a suppression device when switching inductive loads i.e.

electric releases and electric locks.
The enclosed suppression devices
(transil) must be connected as close
as possible to the loads (ideally
across the terminals. See figure).

-

The cables, which are heavily outlined, have a minimum section of 0.75mm² (AWG18).

127V

0

230V

110-127Vac

220-230Vac

127V

0

230V

PRS210ED

- 3 -

The keypad allows for the activation of 2
relays with programmable codes.

Technical data
Power supply

12Vac/dc ±10%

Stand-by current

0.06A

Maximum  current  consumption    0.15A
Contact ratings

12Vac - 2A

Number of codes for relay 1

12 (+ direct
activation)

Number of codes for relay 2

12 (+ direct
activation)

Activation time for each relay from 1 to 99 sec.

(or bistable)

Operating temperature

0° ÷ +40°C

Maximum allowable humidity 85% RH

Terminals
NC2

normally closed contact of relay 2

NA2

normally open contact of relay 2

C2

common contact of relay 2

NC1

normally closed contact of relay 1

NA1

normally open contact of relay 1

C1

common contact of relay 1
ground or alternate voltage input
positive or alternate voltage input

P2

activation of the relay 2; if momentarily
connected to ground it allows the activa-
tion for the programmed time

P1

activation of the relay 1; if momentarily
connected to ground it allows the activa-
tion for the programmed time

ACCESS CONTROL KEYPAD
FC52PL

INSTALLATION DIAGRAM

PROGRAMMING

Default programming
The article is supplied from the factory with
the following codes:

Programming code:

11

Activation code 1 of relay 1:

12345678

Other activation codes of relay 1
(from 2 to 12):

             none

Activation time code of relay 1: 01 (1 sec.)
Operating mode of relay 1: 00 (monostable)
Activation code 1 of relay 2:

90

Other activation codes of relay 2
(from 2 to 12):

             none

Activation time code of relay 2: 01 (1 sec.)
Operating mode of relay 2: 00 (monostable)

All codes are user-modifiable.

Operating modes and programming codes
Monostable

00

Bistable

01

Monostable and direct activat. by key A 02
Bistable and direct activation by key A

03

Changing the programming code
To change the programming code:
- enter the actual programming code
- press key A (red LED flashes)
- enter 00
- press key A (red LED on)
- enter the new programming code with 1 to 8

digits (from 0 to 99999999)

- press key A (red LED flashes)
- enter 55
- press key A (red LED off).

Changing the activation codes of relay 1
To change the activation codes of relay 1:
- enter the programming code
- press key A (red LED flashes)
- enter 01 (identification code of relay 1)
- press key A (red LED on)

- enter a number with 1 to 8 digits to pro-

gramme code 1 (from 0 to 99999999)

- press key A
- enter a number with 1 to 8 digits to pro-

gramme code 2 (from 0 to 99999999)

- press key A
- enter a number with 1 to 8 digits to pro-

gramme code 3 (from 0 to 99999999)

- press key A
- repeat the operation to programme all codes

as necessary (max.12). When program-
ming is completed press key repeatedly
until the red LED starts flashing

- enter 55
- press A (red LED off).

Changing the activation codes of relay 2
To change the activation codes of relay 2
follow the procedure described above, chang-
ing the relay identification code (02 instead of
01).

Changing one relay activation code
To change one relay activation code, without
modifying the others:
- enter the programming code
- press key A (red LED flashes)
- enter 01 or 02 (for relay 1 or 2, respectively)
- press key A (red LED on)
- press key repeatedly to reach the code to

be changed

- enter a number with 1 to 8 digits (from 0 to

99999999)

- press key repeatedly until the red LED

starts flashing

- enter 55
- press key A (red LED off).

Example
To change activation code 7 of relay 2:
- enter the programming code
- press key A (red LED flashes)
- enter 02
- press key A (red LED on)
- press key six times
- enter a number with 1 to 8 digits
- press key six times (red LED flashes)
- enter 55
- press key A (red LED off).

Deleting one relay activation code
To delete one relay activation code, without
modifying the others:
- enter the programming code

Installation of the intercom

Reviews: