USE AND MAINTENANCE MANUAL - SECTION 7
AERIAL PLATFORM ELEVAH 65-80 ES MOVE
– Rev. 03_2019
Page 7-2
ATTENTION
THE RECOMMENDED FREQUENCY OF LUBRICATION AND OF THE WEAR
CHECKS IS BASED ON NORMAL USE. IF THE MACHINE IS USED FOR HEAVY
DUTY WORK, SUCH AS A HIGH NUMBER OF CYCLES, UNFAVOURABLE
POSITION, CORROSIVE/DIRTY ENVIRONMENT, ETC., THE USER MUST
INCREASE THE FREQUENCY OF THE CHECKS ACCORDINGLY.
MONTHLY MAINTENANCE
•
Torque Reducer
Check the oil level and proper closing of the lubricant filler cap and drain
plug of the Torque Reducer;
MAINTENANCE EVERY THREE MONTHS
•
Check there is no clearance, mechanical parts not correctly
secured and/or bent and no parts/components desoldered;
•
Check the integrity of the structural profiles;
•
Check correct operation of the emergency descent valve.
Take the cage to a height and execute an “emergency descent”, as shown
in the relative section of this manual.
•
Hydraulic Oil
Check the level of hydraulic oil and top up, if necessary.
Refer to the specifications described in the relative paragraph for
information regarding hydraulic oil checks and top-up;
•
Check the hydraulic oil piping connections and make sure there are
no leaks;