FAR ELECTRONIC CONTROLLER

Art. 9611

SIMPLIFIED USER MANUAL

FAR electronic controller art. 9611 is suitable for heating systems with 3-point mixing valve and is preset for fixed point 

operation, or with temperature compensation dependant on the external temperature. Each electronic controller can 

control one 3-point mixing valve and can be connected to one flow sensor and /or one outside sensor.

The package includes:

N°1 

control unit

N°1 

electrical connections support

N°1 

supply temperature probe

N°1 

assembly kit in contact with supply probe

N°1 

outside temperature sensor

N°1 

seat for Ø6 mm probe

Instruction manual

Front panel description:

DISPLAY:

Valves opening Mix.

Pump starting.

Communication ok

Valves closing Mix.

The presence of an arrow next to a symbol 

indicates that the function is active.

MAIN SELECTOR:

Switched off regulation (anti-freeze only).

Not provided

With external probe: nominal room T .

Fixed point: not provided.

Automatic function.

Manual operation /test.

BUS address.

Mixing valve dynamics.

With external probe:max supply T.

Fixed point: system supply T.

With external probe: heating curve

Fixed point: not provided.

INCREMENTAL SELECTOR:

Changes parameter value.

Decrease.

Increase.

+ -

FUNCTION BUTTON:

Select a value to modify.

Reset controller.

Confirm the value modified.

OK

The electronic controller art. 9611 permits control of a mixing valve and a pump in relation to the mixed circuit of a 

heating system. 

It is supplied pre-programmed and it can operate 

  at  a  fixed  point

 with delivery probe only or 

with temperature 

modulation

, if both supply probe and external probe are connected.

Before putting the product into service it will be necessary to set the values relating to the desired functions.

 

 

1

www.far-moscow.ru  Москва, ул. Народного Ополчения, д. 34, стр. 3  (499) 519-03-69 

Summary of Contents for 9611

Page 1: ...s that the function is active MAIN SELECTOR Switched off regulation anti freeze only Not provided With external probe nominal room T Fixed point not provided Automatic function Manual operation test B...

Page 2: ...n connected it is essential to make a jumper between terminals 15 and 16 It is always necessary to create a jumper between terminals 2 and 3 and also between terminals 3 and 10 ROOM THERMOSTAT EXTERNA...

Page 3: ...rews again and check keep separate the cables of sensors and digital inputs from the inductive and power cables to avoid interference When connecting control units you must Putting the control unit in...

Page 4: ...ary to change only the value of parameter and it is not necessary to reset any other parameters BUS address 1 Mixing valve dynamics Desired supply T value Parameter description Selector Turning the ha...

Page 5: ...PROM control function The software loaded on the control unit checks automatically all the preset parameters every 10 minutes If one parameter is not within the limits indicated it will be replaced by...

Page 6: ...BLACK wire of the actuator to the terminal identified by number 9 Connect the BROWN wire of the actuator to the terminal identified by number 6 For the connection of the regulating units for underflo...

Page 7: ...ocated in the box with the control unit place the probe directly in contact with the supply pipe and secure it with the cable tie CONTACT INSTALLATION 1 2 Tee fitting NOT PROVIDED 1 Tee fitting NOT PR...

Page 8: ...g with DIN EN 60529 IP 40 Protection class complying with DIN EN 60730 II totally insulated Permitted ambient temperature during operation 0 a 50 C Permitted ambient temperature for storage 20 to 60 C...

Page 9: ...FAR 9611 FAR 9611 3 3 1 1 1 1 1 1 6 1 2 1 www far moscow ru 34 3 499 519 03 69...

Page 10: ...15 16 2 3 3 10 220 50 N N N L 2 www far moscow ru 34 3 499 519 03 69...

Page 11: ...1 N 220 2 3 10 L 220 4 6 9 15 16 18 19 21 22 90 RESET EE RUN 3 5 40 C 01 15 05 25 20 110 C 20 110 C 0 0 3 0 00 03 20 C 01 12 80 C 40 C 1 2 00 www far moscow ru 34 3 499 519 03 69...

Page 12: ...12 5 25 18 19 15 16 1 RUN 0 4 0 6 1 0 1 5 4 18 19 21 22 www far moscow ru 34 3 499 519 03 69...

Page 13: ...RUN 0 7 EEPROM 10 E81 5 24 5 24 5 0 1 2 3 RUN www far moscow ru 34 3 499 519 03 69...

Page 14: ...FAR 2170 9 6 9 6 9 6 FAR 3490 3491 3568 3569 3570 3571 FAR 301020 301021 301022 9 6 1 N 9 6 6 www far moscow ru 34 3 499 519 03 69...

Page 15: ...2 N 9 6 1 1 2 7 1 2 1 1 2 1 2 1 2 1 1 1 2 1 2 1 1 www far moscow ru 34 3 499 519 03 69...

Page 16: ...10 C 9952 20 C 6247 25 C 5000 30 C 4028 40 C 2662 50 C 1801 60 C 1244 70 C 876 80 C 628 90 C 458 100 C 339 110 C 255 120 C 194 DIN IEC 60 038 220 10 5 250 2 2 Corrente max su morsetto L1 6 3 A DIN EN...

Reviews: