Revision - 04
Date 12-2009
13
GB
EB 310
EB 310
WARNING!
The riveting tool must be shut off during the
above operations.
MAINTENANCE AND SIZE CHANGE
(fig.
f4-f5-f6
)
Prolonged use of the riveting tool may cause the clamps to slide
along the stem due to built-up grime.
You must therefore clean
and lubricate the clamps
, or replace them if heavily worn to
the point of preventing correct use.
Use a 27-mm commercial wrench to remove the tube carrying
nozzle
(B)
. Once the tube has been removed, use a commercial
wrench - 16 mm - to remove the cone
(L)
and extract the clamps
(M)
. To replace the nozzle
(A)
, use the supplied special key
(N)
and place on it the removed nozzle to avoid any loss.
Please note:
prolonged use of the riveting tool may cause a
normal wear of the microswitch, of the motor or of the printed-
circuit board inside the handgrip. To avoid a further damage of
the tool, proceed in replacing the microswitch, the motor or the
printed-circuit board (see following chapters).
f4
B
B
f5
f6
A
N
A
L
L
M
WARNING!
If the clamps holding cone is not well
locked, the riveting tool may be seriously
damaged.