background image

WWW.FANTOMRACING.COM

ESC FIRMWARE FLOW CHART (Fantom LCD Program Card required to edit)

0-64˚ (1˚ increments)

RPM

Full Throttle

Instant

1-10 (1 step increments)

0.9s

0.8s

0.7s

0.6s

0.5s

0.45s

0.4s

0.35s

0.3s

0.25s

0.2s

0.15s

0.1s

0.05s

1.0s

Instant

Full Th RPM

Boost

Turbo

8,000 RPM to 50,000 RPM (1,000 RPM increments)

1-10 (1 step increments)

0-64˚ (1˚ increments)

1-50 (1 step increments)

1-10 (1 step increments)

Boost Timing

Boost Trigger Level

Boost Trigger Rate

Turbo Timing

Activation

Method

Turbo Delay

Turbo Timing

Start RPM

Turbo On

Rate

Turbo Off

Rate

Normal

Modified

Reverse

Stock (Blinky)

6.0V

7.4V

0%

12.5%

25%

37.5%

50%

62.5%

75%

87.5%

100%

Linear

Custom (must use PC Interface)

Linear

Custom (must use PC Interface)

4%-15% (1% increments)

1%-20% (1% increments)

0%-100% (1% increments)

1-30 (1 step increments)

1-30 (1 step increments)

1K, 2K, 4K, 8K, 16K

1%-100% (1% increments)

1-20 (1 step increments)

1-20 (1 step increments)

1K, 2K, 4K, 8K, 16K

Forward / Brake

Disable

203˚F / 95˚C

221˚F / 105˚C

266˚F / 130˚C

Disable

Forward / Brake / Reverse

Auto(3.3V/Cell)

Forward / Reverse

Custom 3.0v to 11.1v (0.1v increments)

Yes

No

Running Mode

Low Voltage Cut-off

ESC Over-heat

Motor Rotation

Race Mode

Dead Band

BEC Output

IP- Limiter

Throttle Rate

Drive Frequency

RPM Lock

Throttle Curve

Initial Brake

Drag Brake

Brake Force

I-Brake Response

Brake Rate

Brake Frequency

Brake Curve

Off By Radio

Application

Throttle

Brake

Timing

PROGRAMMABLE ITEM

PROGRAMMABLE VALUE

SECTION

Summary of Contents for FR-10 PRO ESC

Page 1: ...ESC white to the right side and the other end into the socket of your LCD Card marked with black to the right side 3 Connect the battery to the ESC and turn on the ESC 4 If the connection is correct...

Page 2: ...ION FUNCTIONS DESCRIPTIONS GENERAL G G1 RUNNING MODE Forward Brake Forward Brake Reverse Forward Reverse Use this function to set whether you want forward brake only forward and brake and reverse or f...

Page 3: ...ues provide more aggressive feel High values provide a smoother feel Typically use the lower values for spec stock motors and the higher values for modified motors TH4 RPM LOCK 1 to 100 1 increments U...

Page 4: ...hat when you push the brake 10 the ESC will brake 25 and so on The settings can also be reversed For example you can set it so that when you push the brake 10 the ESC will brake 5 and so on Typically...

Page 5: ...tant 0 05 seconds to 1 second 05 second increments default 0 3 seconds Use this function to control the delay time required to activate the TURBO TIMING once the activation conditions are achieved fro...

Page 6: ...wnload latest Fantom FR 10 PRO ESC firmware here www fantomracing com downloads 5 The above 4 steps only need to be done once unless we release new updates to the PC Interface app or new firmware Once...

Page 7: ...rom the ESC 4 Plug the included signal wire into the PGM port of your ESC white to the right side and the other end into the socket of your LCD Card marked with black to the right side 5 Connect the b...

Page 8: ...splayed on the LCD screen and the ESC button on the home screen of the PC Interface app will change from gray to red You are now ready to use the PC Interface to customize your ESC 1 Click on the Gene...

Page 9: ...25 37 5 50 62 5 75 87 5 100 Linear Custom must use PC Interface Linear Custom must use PC Interface 4 15 1 increments 1 20 1 increments 0 100 1 increments 1 30 1 step increments 1 30 1 step increment...

Page 10: ...ipt 2 Your name return address day time phone number and email address 3 A brief note explaining the problem you are experiencing 4 Your LCD Program Card well protected inside the box If we receive yo...

Page 11: ...ot hold Fantom responsible for any damages and or injury incurred by improper use or improper judgment in using this product Fantom Racing reserves the right to change the provisions of this warranty...

Reviews: