Fantom FM780 Instruction Manual Download Page 12

Cleaning the blockage in the nozzle air inlet pipe

Press release button F to 
remove the upper case.

Remove the blockage in 
the nozzle air inlet pipe.

Reattach the vacuum 
cleaner.

If the nozzle head still appears to be blocked, please clear the blockage in the nozzle air inlet pipe.

Release Button F

Screw

Nozzle air 
inlet pipe

CLEARING BLOCKAGES IN THE SUCTION HOSE
AND CLEANING THE AGITATOR ASSEMBLY

Caution:

 Be sure to turn the ON/OFF switch to the "OFF"  position and disconnect 

                 the  power cord  from the  wall outlet before clearing any blockages in the 

                 suction hose and cleaning the agitator assembly.

11

Clearing blockages in the suction hose

1

Set the vacuum cleaner to the upright position.

2

  

 

 

 

 

 

Remove the hose cuff from the suction inlet and

  

 

 

 

 

then remove any blockages from the hose.

3

Pull the dust inspection cover away from body and  
push out the dust clogging the bypass tube assembly.

Cleaning the agitator assembly 

When threads get caught in the agitator assembly, clean the assembly.

Remove the bottom plate (refer to page 14).
Remove threads caught in the assembly by cutting them
with scissors.
 

Scissors

Threads

Clearing blockages in the nozzle head

Remove the bottom plate (refer to page 14)

Remove any blockages from the nozzle head.

Reattach the bottom plate to the nozzle head,and 

then operate the vacuum cleaner to check that the 

blockage has been properly cleared. If the nozzle 

head is still blocked, the suction force will be weak.

Nozzle Head

4

 

 

 

  

  

  

 

Reattach the hose cuff to the suction inlet,and the 
dust inspection cover to the bypass tube assembly.
Now switch on

 

 

the

 

vacuum

 

cleaner

 

to

 

check that

  

  

  

  

  

  

  

the blockage has been properly cleared. If the hose

 

 

 

  

  

 

 

  

is still blocked, the suction force will be weak.

Hose Cuff

Suction Inlet

Dust Inspection

Cover

Bypass Tube
Assembly

Nozzle air 
inlet pipe

Caution: 

Make sure that

the Release Button F is
at the original position.

Caution:

Remove screw before
pressing release button F.

Summary of Contents for FM780

Page 1: ...EANER USING THE ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY REPLACEMENT INSTRUCTIONS TROUBLESHOOTING REPLAC...

Page 2: ...et Door 16 Plattsburgh NY 12901 6 Do not pull or carry by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the vacuum cleaner over t...

Page 3: ...cleaner allow all metal parts to cool first 24 Always place foot on handle release when adjusting the handle position 25 If the supply cord of this appliance is damaged it must only be replaced by FA...

Page 4: ...Lever R ug Floor Tools S E LE C TOR Crevice Tool Power C ord Plug Power Cord Upholstery Tool Dusting Brush F R ONT R E A R R eleas e B utton D Cleaning Utensil Handle S uction Hos e Dust C ompartment...

Page 5: ...1 2 Attaching the handle PREPARATION BEFORE USE Caution Do not connect the power cord plug to the wall outlet until assembly is completed Set the vacuum cleaner to the upright position lnsert the han...

Page 6: ...the hook to the upright position before attempting to rewind the power cord INSERTING THE POWER CORD PLUG WARNING To reduce the risk of electric shock this appliance has a polarized plug one blade is...

Page 7: ...of this vacuum cleaner can be set to one of three positions Upright Normal or Parallel Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright p...

Page 8: ...T he R UG F LOOR T OOLS s elector s hould only be adjus ted while the vacuum cleaner is turned on and in the upright pos ition W hen cleaning a rug or carpet firs t turn the ON OF F s witch to the ON...

Page 9: ...n the handle Attach the attachments as shown below When you have finished using the attachments replace them in their original positions as shown on page 4 8 Wand Crevice Tool Upholstery Tool Upholste...

Page 10: ...e OFF position and disconnect the power cord from the wall outlet before cleaning Empty the dust compartment when contents reach the MAX mark Press the release button A meanwhile press the release but...

Page 11: ...to clean filters This may result in damage to the filters Do not attempt to dry with a hair dryer or by placing in a clothes dryer Hot air may cause the filters to warp Reattaching the filters Insert...

Page 12: ...g the bypass tube assembly Cleaning the agitator assembly When threads get caught in the agitator assembly clean the assembly Remove the bottom plate refer to page 14 Remove threads caught in the asse...

Page 13: ...cing any of the parts below REPLACING THE HEADLIGHT LAMP 1 2 3 4 5 6 Set the vacuum cleaner to the parallel position Loosen the screws to remove the lens When removing the headlight lamp be careful no...

Page 14: ...ow REPLACING THE FLAT BELT Remove the bottom plate refer to page 14 Lift out the agitator assembly and then remove the flat belt from the motor shaft and the agitator pulley Place a new flat belt onto...

Page 15: ...4 1 3 1 2 3 REPLACEMENT INSTRUCTIONS REMOVING THE BOTTOM PLATE Insert the projection on the bottom plate into the groove on the nozzle head and set the bottom plate in place Push the bottom plate as...

Page 16: ...ON position Suction force is weak The agitator does not operate The power cord plug is not securely inserted into the wall outlet The flat belt is worn or broken Insert the power cord plug securely i...

Page 17: ...This warranty is extended to the original purchaser of the unit and excludes all other legal and or conventional warranties The responsibility of FANTOM if any is limited to the specific obligations e...

Reviews: