Fantom FM732C Owner'S Manual Download Page 5

Air intake

duct

OPERATING INSTRUCTIONS

Assembling Your Vacuum Cleaner

Note:

Always remove the power plug 

from the wall outlet before assembling or 
removing accessories.

4

Fitting the Floor to Carpet Brush 
to the Telescopic Tube

Push the telescopic tube into the floor 
brush as show in the illustration below.

Telescopic 

Tube

Floor to Carpet 
Nozzle

Fitting the Telescopic Tube to 
the Curved Wand / Hose 
Extension

Push the telescopic tube into the 
curved wand / hose extension, as 
shown in the illustration below. Make 
sure that the telescopic tube locks in 
place.

Plastic
Button

Extending the Telescopic Tube 

Push forward on 
the plastic button 
and pull the inner 
tube outward.

Attaching the Flexible Hose into 
the Vacuum

Connect the flexible hose into the air 
intake duct. Push in until you hear a 
“click”, indicating it is in its locked 
position.
To remove the flexible hose press 
inward on lock tabs and slide hose 
outward.

Air Driven Turbo Brush

The efficiency of your Air Driven 
Turbo Brush depends on the bristle 
brush rotating at high speed. Strong 
air suction is needed to accomplish 
this. In order to endure that maximum 
air suction is maintained, please read 
the following instructions:

Empty the Dust Cup frequently 
during use.

Always “

TapClean

” the HEPA 

dust cup filter and debris screen 
each time the dust cup is 
emptied.

Ensure that the rotating bristle 
brush is kept free of hair and 
string.

Inspect the turbine regularly to 
ensure that the air passage is 
free of dirt and debris.

Hand Held Air Driven 

Turbo Brush

Air Driven Turbo 

Brush

Changement et nettoyage du filtre 
post-moteur

Le filtre post-moteur est lavable mais doit 
être remplacé à chaque période de six 
(6) mois selon l’usage. N’utilisez jamais 
l’aspirateur sans que TOUS ses filtres 
soient en place.
• Mettez le commutateur en position 

d’arrêt (« Off ») et débranchez 
l’aspirateur.

• Le filtre post-moteur est situé à 

l’arrière de l’aspirateur.  Retirez le 
couvercle du filtre. 

• Retirez la grille du filtre et sortez le 

filtre.

• Rincez-le à l’eau tiède et laissez-le 

sécher à l’air complètement.  Ne 
rincez pas le filtre à la laveuse. Ne le 
séchez pas au séchoir à cheveux.  
Laissez-le sécher à l’air pendant 24 
heures. 

• Lorsque le filtre est bien sec, 

remettez-le en place dans la grille et 
ensuite dans l’aspirateur.

Remarque

:

Le filtre HEPA de la coupelle à
poussière peut être lavé. Nous vous 
recommandons toutefois de le changer 
à chaque période de six (6) mois pour 
assurer un rendement optimal de 
l’aspirateur. 
Le filtre pré-moteur et post-moteur sont 
lavables. Ils doivent toutefois être 
remplacés à chaque période de six (6) 
mois pour assurer un rendement 
optimal de l’aspirateur. 

Important

:

Assurez-vous que TOUS 

les filtres sont bien secs avant d’être 
remis dans l’aspirateur

Important

:

Tous les filtres doivent être 

inspectés régulièrement à l’affût de 
dommages, préférablement après 
chaque tâche de nettoyage.  S’ils sont 
endommagés, ils doivent être 
remplacés immédiatement.  Avant de 
vérifier les filtres, débranchez toujours 
l’aspirateur.

OPERATING INSTRUCTIONS

19

Fitting the Air Driven Turbo Brush 
to the Telescopic Tube 

Push the telescopic tube 
into the air driven turbo 
brush as show in the 
illustration.

Summary of Contents for FM732C

Page 1: ...UIDE DU PROPRI TAIRE Model Mod le FM732C 120V 60Hz 10 3 Amps Fantom 94 Main Mill Street Door 16 Plattsburgh NY 12901 Tel 1 800 275 9251 www fantom com Bagless Canister Vacuum Aspirateur tra neau Copyr...

Page 2: ...d uvre pour une p riode d un 1 an compter de la date d achat Cette garantie ne couvre que l usage domestique normal Si votre appareil cesse de fonctionner correctement dans le cadre d un usage domest...

Page 3: ...u Ne PAS laver le filtre dans le lave vaisselle Il est important lors du lavage du filtre HEPA de le laisser s cher COMPL TEMENT avant de l utiliser encore Nous vous recommandons de le laisser s cher...

Page 4: ...tat de marche lors de son envoi Si un probl me mineur survient il est souvent facile de le r soudre en d couvrant d abord sa cause La grille ci dessous pourra vous aider cet gard PROBL ME RAISON POSSI...

Page 5: ...e of dirt and debris Hand Held Air Driven Turbo Brush Air Driven Turbo Brush Changement et nettoyage du filtre post moteur Le filtre post moteur est lavable mais doit tre remplac chaque p riode de six...

Page 6: ...nt bien en place Mettez le commutateur en position d arr t Off et d branchez l aspirateur Le filtre post moteur est situ l arri re de l aspirateur Retirez le couvercle du filtre Retirez la coupelle de...

Page 7: ...et le picoter dans le sens contraire des aiguilles d une montre pour le d gager du contenant de la coupe poussi re DIRECTIVES D USAGE Avertissement Apr s chaque usage toujours retirer le filtre TapCl...

Page 8: ...Pour enrouler le cordon appuyez sur le bouton d enroulage du cordon avec une main et dans l autre main tenez la fiche du cordon pour viter qu elle fouette et cause des dommages et des blessures Suceur...

Page 9: ...r l aspirateur avant d assembler ou d enlever ses accessoires Fixation de la brosse plancher 15 tapis au tube t lescopique Pressez le tube t lescopique dans la brosse tel qu illustr ci dessous Tube t...

Page 10: ...se Sound Changes 1 Attachment use restricts airflow 2 New carpet trimmings clogging air passage 1 Check attachment 2 Remove obstruction 9 MESURES DE S CURIT 14 1 vitez d utiliser l aspirateur trop pr...

Page 11: ...ilter or the exhaust filter you allow them to dry COMPLETELY before using again We recommend 24 hours to air dry DO NOT DRY IN DRYER All filters should be checked regularly for signs of damage prefera...

Page 12: ...Rangez l aspirateur l int rieur dans un endroit frais et sec 23 Assurez vous que votre aire de travail est bien clair e 24 vitez d immerger l aspirateur dans de l eau ou autres liquides 25 Tenez loign...

Reviews: