background image

Caution:

 Be sure to turn the ON/OFF switch to the "OFF"  position and disconnect 

Cleaning the agitator assembly 

1

2

3

CLEARING BLOCKAGES AND CLEANING 
THE AGITATOR ASSEMBLY

                 the  power cord  from the  wall outlet before clearing any blockages in the 
                 suction hose and cleaning the agitator assembly.

Cleaning blockages 

Remove the bottom plate(refer to page 14)

Remove any blockages from the nozzle head.

Reattach the bottom plate to the nozzle head, and then operate the vacuum cleaner
to check that the blockage has been properly cleared. If the nozzle head is still blocked,
the suction force will be weak. 

Cleaning blockages in the nozzle head

When threads get caught in the agitator assembly, clean the assembly.

Remove threads caught in the assembly by cutting them
with scissors.
 

11

Remove the bottom plate(refter to page 14)

Set the vacuum cleaner to the upright position.

  

 

 

 

 

 

Remove the hose cuff from the suction inlet and

  

 

 

 

 

then remove any blockages from the hose.

 

 

 

  

  

  

 

 

  

  

 

 

Reattach the hose cuff to the suction inlet,and

  

  

  

  

  

  

  

then operate the vacuum cleaner to check that

 

 

 

  

  

 

 

  

the blockage has been properly cleared.If the hose
is still blocked,the suction force will be weak.

1
2

3

Scissors

Threads

Nozzle Head

Hose Cuff

Suction Inlet

Suction Hose A

Cleaning blockages in the suction hose A, B

When the suction hose A, B or Nozzle head is
blocked, the bypass valve will be opened
automatically to protect the motor, resulting
in the suction force being reduced. The bypass 
valve will be at its original position automatically
after the blockage is removed.

Caution:

Bypass Valve
 (Inside)

Summary of Contents for FM655CS

Page 1: ...ING THE ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY REPLACEMENT INSTRUCTIONS TROUBLESHOOTING LIMITED WARRAN...

Page 2: ......

Page 3: ...ay from heated surfaces 7 Do not unplug by pulling on the cord To unplug grasp the plug not the cord 8 Do not handle the plug or the vacuum cleaner with wet hands 9 Do not put any objects into the ope...

Page 4: ...is intended for household or commercial use Note to user concerning attachment plug 2 This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least resistan...

Page 5: ...ction Hose A Dust Compartment Carrying Handle DusterKnob ON OFF Switch Release Button A Release Button B Release Button C Suction Hose B Filter Cover Wand Handle Release Lever Power Cord Upholstery To...

Page 6: ...A Caution Do not connect the power cord plug to the wall outlet until assembly is completed Attaching the handle PREPARATIONS BEFORE USE Attaching the suction hose A attachments 4 1 2 Set the vacuum c...

Page 7: ...becomes full and you continue to run the machine the vacuum will shut off automatically to prevent the motor from overheating If this happens turn off slide switch and disconnect your vacuum from powe...

Page 8: ...HANDLE Upright position The handle is normally locked in this The handle of this vacuum cleaner can be set to one of three positions Upright Normal Parallel Place your foot on handle release lever as...

Page 9: ...selector to the RUG position When cleaning a bare floor or when using one of the attachments set the RUG FLOOR TOOLS selector to the FLOOR position Caution Do not change the setting of the RUG FLOOR T...

Page 10: ...older mount Holder Mount Hose Holder When you have finished using the attachments replace them in their original positions as shown on page 4 Tabs Groove Upholstery tool Dusting brush To detach the du...

Page 11: ...rd from the wall outlet before cleaning Empty the dust compartment when contents reach the MAX mark Press the release button A meanwhile press the release button B to remove the dust compartment Press...

Page 12: ...th a hair dryer or by placing in a clothes dryer Hot air may cause the filters to warp Reattaching the filters Insert the main filter into the prefilter as shown 10 The main filter and prefilter will...

Page 13: ...ssembly clean the assembly Remove threads caught in the assembly by cutting them with scissors 11 Remove the bottom plate refter to page 14 Set the vacuum cleaner to the upright position Remove the ho...

Page 14: ...When removing the headlight lamp be careful not to pull on the headlight lamp wiring 4 Remove the lamp by pushing it gently in the direction of the arrow and then turning it counterclockwise 5 Push a...

Page 15: ...emove the bottom plate refer to page 14 Lift out the agitator assembly and then remove the flat belt from the motor shaft and the agitator pulley Place the agitator assembly into the grooves in the no...

Page 16: ...late by pulling the tabs as illustrated REATTACHING THE BOTTOM PLATE Insert the projection on the bottom plate into the groove on the nozzle housing and set the bottom plate in place Push the bottom p...

Page 17: ...REPLACING THE FILTER Caution Do not wash the sub filter in a washing machine and do not use any other equipment such as a hair dryer to dry it Always allow 24 hours for drying Do not operate the vacuu...

Page 18: ...e ON position Suction force is weak The agitator does not operate The power cord plug is not securely inserted into the wall outlet Insert the power cord plug securely into the wall outlet refer to pa...

Page 19: ...y unit that has been tampered with or used for commercial purposes This limited warranty does not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandlin...

Reviews: