OPERATING INSTRUCTIONS

1. On/Off Button
2. Fan Speed Button
3. Timer
4. Set-Up
5. Neutralize Button
6. Ionizer Button
7. Increase Button
8. Decrease Button

The Remote Control

7

IMPORTANT

: The remote control requires 

two (2) AAA batteries which are not 
included with the unit. Do not mix old and 
new batteries. Do not mix alkaline, 
standard (carbon-zinc) or rechargeable 
(nickel-cadmium) batteries together.

NOTE:

The remote control functions best 

at a distance of less than 20 feet (6 
meters).

1. On/Off Power Button

This controls the power to the unit.

2. Fan Speed Button

Each time this button is pressed it 
will cycle through the options for the 
fan speed. (See Using the Air Purifier.) 

3. Timer Button

This button only controls when the 
unit will shut-off automatically.

4. Set Up Button (Pre-Program)

This allows you to pre-program “On” 
time, “Off” time, and fan speed.
This feature can be used even if the air 
purifier is “Off”.

5. Neutralize

This button will turn on or turn off the 
photo-catalysis and UV light functions 
remotely.

6

.

Ionizer Button

This button will turn on or turn off the 
ionizer function remotely.

7. Increase Button (“+”)

This button will increase time selected 
in the set up feature by half hour 
increments.

8. Decrease Button (“-”)

This button will decrease time selected 
in the set up feature by half hour 
increments.

Fig. 7

2. While the unit is “Off”, press the 

set up button on the remote 
control. The “On” will flash on the 
timer display panel. 

3. Press the “+” or the “-” button on 

the remote control to set the time. 
Each time you press the “+” 
button, the time will increase or 
decrease up to a maximum of  
9 hours and 30 minutes.
The “+” button will increase the 
time by 30 minute increments and 
the “-” button will decrease by 30 
minute increments.

4. To set the time when the unit will 

turn “Off”, depress the set up 
button again. The “Off” will flash 
on the display panel. Repeat step 
#3 to select desired “Off” time.

5. Depress the set up button on the 

remote control again to set the fan 
speed that is desired. The circle 
diagram around the fan speed will 
flash indicating that fan speed will 
now be adjusted.

6. Depress the fan speed button or 

the increase (“+“) to the required 
fan speed.

7. Once the fan speed is selected, 

after a moment a single “beep” will 
indicate a successful set-up and 
the display panel will display how 
many hours and minutes remain 
until the unit turns “On”.

IMPORTANT

:

Three (3) “beeps” 

and a blank panel indicates incorrect 
data entry. Repeat set-up process.

NOTE:

Auto fan speed is the only 

setting the dust sensors use to adjust 
the fan speed to what is required to 
clean the air. Manual adjustment is 
required if the unit is not in auto 
mode.

To Pre-Program Your Air 
Purifier

Use the set up control button on the 
remote to preset when the unit will 
turn “On”, “Off”, and which fan speed 
is desired when the unit is running.
1. Each time the set up button is 

pressed it goes through one of 
three cycles. (Fig. 7)

OPERATING INSTRUCTIONS

6

Ionizer

NOTE:

The neutralize and the ionizer 

functions are silent  features, the only way 
to know if they are “On” is with the 
indicator lights.
1. To turn the ionizer “On”, press the 

ionizer button on the control panel or 
the remote control. The ionizer “On/Off” 
indicator will illuminate when “On.

2. To turn this feature “Off”, depress the 

ionizer control button or remote button 
again. The ionizer “On/Off” indicator 
will no longer be illuminated. (Fig. 4)

Neutralize 
The neutralize button turns the UV light 
“On” and begins the photo-catalysis 
process.
1. To turn the neutralize feature “On”, 

press the neutralize button on the 
control panel or the remote control. 
The neutralize indicator light will 
illuminate when the feature is “On”. 
(Fig. 5)

2. To turn this feature “Off” depress 

the neutralize button again on 
control panel or remote. The 
neutralize indicator light will no 
longer be illuminated. 

Using the Timer
The timer button has 5 different cycles 
for automatic shut off. To use the timer 
button:
1. Depress the timer control button to 

preset when the unit will turn “Off”. 

2. With this feature, you have a choice 
of  1hr, 2 hrs, 4 hrs or 8 hrs. (Fig. 6)

The Odor Sensor
If the air purifier senses odors in the air, 
the indicator bar will increase to a 
maximum of four (4) bars. Adjust the fan 
speed to a desired level. The air purifier 
will automatically adjust the fan speed 
when it is in “AUTO” mode. (Fig. 3)

Fig. 6

The Dust Sensor
When more dust is detected in the air 
the indicator bar will increase to a 
maximum of four (4) bars. Adjust the 
fan speed to desired level. The air 
purifier will automatically adjust the fan 
speed when it is in “AUTO” mode. 
(Fig. 3)

Fig. 3

Ionizer

Button

Ionizer

Indicator Light

Fig. 4

Neutralize Button

Fig. 5

Neutralize

Indicator Light

Odor Sensor 
Indicator Bar

Dust Sensor

Indicator Bar

Reviews: