73
C
OPERATION
Intellicomfort CH180 has 6 touch-keys, which function depends on the situation and is described by the symbol that appears on the
display.
graphic portion:
messages / temperature
timing
programs
summer / winter
mode
primary
function
secondary
function
Celsius/Fahrenheit room
temperature
hour
day of the week
summer ON relay
winter ON relay
INSTALLATION
Intellicomfort CH180 has to be installed on the wall or in a 3 modules or round flush mounting box, at about 1,5 meters above the floor.
low batteries
OPERATION MODES
Intellicomfort CH180 programmable thermostat allows different modes of use, called programs:
MAN
Manual program
AUTO
Weekly program
HOLIDAY
Daily program
JOLLY
Temporary program
OFF
Switched off system or antifreeze program
MAN
Intellicomfort CH180 programmable thermostat adjust the room temperature
using the temperature set in 24 hours.
AUTO
Intellicomfort CH180 programmable thermostat manages the set temperatures according to the time programs on the weekly profile.
It is provided with 1 preset winter program and 1 preset summer program.
In the Auto mode it is possible to set 3 temperature levels (T1-T2-T3).
T1 can be set from 2°C to 40°C
T2 can be set from 2°C to 40°C
T3 can be set from 2°C to 40°C
Ta antifreeze temperature can be set from 2°C to 7°C
Note: T3 cannot be lower than T2 and T2 cannot be lower than T1.
TMAN: Adjustable temperature
from 2°C to 40°C
Winter program
Monday-Friday
Summer program
Monday-Friday
Winter program
Saturday-Sunday
°C
°C
°C
T3 20
6.30
6.30
9 11.30
11.30 14
14
17
17
22.30
22.30 24h
24h
24h
24h
24h
24h
0
0
5
8
18.30
18.30 22.30
22.30
8 11.30
11.30
22.30
22.30
T2 19
T1 17
T3 20
T2 19
T1 17
T3 28
T2 26
T1 24
°C
Tman 21
24 h