22
Remote management
#AUTO1 to set the AUTOMATIC1 programme (valid for C46A, C52,
C54, C56, C76CT)
#AUTO2 to set the AUTOMATIC2 programme (valid for C46A, C52,
C54, C56, C76CT)
#RESUME to resume the programme set on the chronostat; output
relay position will remain
Alarm commands
#TEL1= XXXXXXXXXX* to set the first phone number to which alarm
messages shall be sent. Replace “XXXXXXXXXX” with the phone
number to be stored.
NOTE: Command shall always end with character “*” (asterisk)
#TEL2= XXXXXXXXXX* to set the second phone number to which
alarm messages shall be sent. Replace “XXXXXXXXXX” with the
phone number to be stored.
NOTE: Command shall always end with character “*” (asterisk)
#TEL1= * to cancel the previously stored phone number 1
#TEL2= * to cancel the previously stored phone number 2
#TEL=? to know stored phone numbers
#AL1=0,TEL1, TEL2 to set alarm1 sending condition and which num-
bers shall receive the message. In this case alarm will be sent at con-
tact closing to both TEL1 and TEL2. Alarm sending can be selected
as follows:
0 = alarm sending at contact closing
1 = alarm sending at contact opening
2 = alarm sending at both contact opening and closing
add writing “TEL1, TEL2” to send the alarm to both stored numbers.
(NOTE: always enter writing “TEL1, TEL2” although just one phone
number has been set).