Installation
Location
The HRV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV would be located in the
mechanical room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not normally
recommended due to extreme temperatures, and difficulty in performing required service & maintenance. If an attic is selected, special care should be
taken in ensuring the unit will perform as intended. Unit may need to be protected with insulated shelter, built on site.
Connecting appliances to the HRV
It is not recommended, including:
• clothes dryer
• kitchen exhaust hoods
• combustion venting
• central vacuum system
These appliances may cause lint, dust or grease to collect in the HRV , damaging the unit.
Connecting any of these type of appliances to the HRV will invalidate your warranty
A
B
C
D
E
F
G
Model
A
B
C
D
E
F
G
Kg
lbs
Kg
lbs
in.
mm.
Kg
lbs
Kg
lbs
Kg
lbs
in.
mm.
SHR 6904/6905R
23.8
22.5
22.5
49.6
15.4
390
85
187
20
44
18.8
41.3
17.6
448
SHR 8004
20
44
17
37.5
15.9
404
71.5
158
19
41.9
16.5
36.4
11
282
SHR 11004/11005R
30.4
67
27
60
21.4
544
109
241
27.7
61
24.3
53.5
18
455
SHR 14104
29.2
64.4
24.5
54
19
483
116
255
30
66.2
34.7
76.5
10
254