3

SER Series

SER 1504

FEATURES

• Compact design
• Backward curved impellers
• Electrostatic filters (washable)
• Enthalpy energy recovery core
• External screw type dry contacts for optional controls
• Improved core guide channels for easy removal of core

OPTIONAL CONTROLS

• EDF 5 

–  Digital multi-function wall control 

with cycle timer

• EDF 2 

–  Digital multi-function wall control

• MDEH 2  –  Mechanical low voltage dehumidistat with

On/Off switch

• MDEH 1  –  Mechanical low voltage dehumidistat
• RTS 2

– 15 Minute pushbutton timer

• FD 30M 

–  30 Minute crank timer

• AQS 1 

–  Air quality sensor

WARRANTY

• 7 year on motors
• 5 year on parts
• 5 year on core (limited)

SPECIFICATIONS

CASE

24 gauge galvanized steel. Baked powder coated paint,

antique white. Insulated with 1" (25 mm) high density
polystyrene foam to prevent condensation and meet the
requirements of the Underwriters Laboratories 94HF.

MOTORS

Two (2) German-engineered, factory-balanced

ebm™ motors with backward curved blades. Motors come
with permanently lubricated sealed ball bearings guarantee
long life and maintenance-free operation. Seven (7) year
warranty.

CORE

A enthalpy energy recovery core configured for an

efficient cross-flow ventilation. Core is 9" x 9" (229 x 229
mm) with a 15" (380 mm) depth. Cores are manufactured to
withstand extreme temperature variations.

FILTERS

Two (2) Washable Electrostatic Panel Type Air Filters,

SER 1504 is 8.5" (216mm) x 15" (380mm) x 0.125" (3mm),

CONTROLS

External three (3) position (Low/Stand

By/Medium) rocker switch that will offer continuous
ventilation. Fantech offers a variety of external controls. (see
optional controls)

DEFROST

During the defrost sequence, the supply blower shuts

down and the exhaust blower switches into high speed to
maximize the effectiveness of the defrost strategy.

INSTALLATION

Unit is typically hung by using installation kit

supplied with unit. Mounting bolts provided on top four (4)
corners of unit.

SERVICEABILITY

Core, filters, motors and drain pan can be

easily serviced through latched access door. Core
conveniently slides out with ease on an improved railing
system. Electrical box, placed on the outside of the unit, can
also be easily accessed.

Energy Recovery Ventilator

Exhaust at 

High Speed

Distributed by:

Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ fea-
tures, designs, components and specifications to maintain their technological leadership position.

Summary of Contents for SER 1504

Page 1: ...of mechanical equipment i e a forced air furnace or air handler operating at a higher static After installation the compatibility of the two pieces of equipment must be confirmed by measuring the airflow s of the Energy Recovery Ventilators by using the balancing procedure found in this manual It is always important to assess how the operation of any ERV may interact with vented combustion equipme...

Page 2: ...ng an authorized service centre near the purchaser or in the general area Fantech reserves the right to supply refurbished parts as replacements Transportation removal and installation fees are the responsibility of the purchaser The purchaser is responsible to adhering to all codes in effect in his area The warranty is limited to 5 years on parts and 7 years on the motor from the date of purchase...

Page 3: ...lpy energy recovery core configured for an efficient cross flow ventilation Core is 9 x 9 229 x 229 mm with a 15 380 mm depth Cores are manufactured to withstand extreme temperature variations FILTERS Two 2 Washable Electrostatic Panel Type Air Filters SER 1504 is 8 5 216mm x 15 380mm x 0 125 3mm CONTROLS External three 3 position Low Stand By Medium rocker switch that will offer continuous ventil...

Page 4: ...IVENESS NET MOISTURE TRANSFER Submitted by Date Qty Model Comments Project Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 25 50 75 100 125 150 175 200 cfm l s n x 0 47 in w g Pa n x 248 Net Supply Net Exhaust Specifications and Ratings Model SER 1504 Total assembled weight 45 lbs Cabinet 24 ga steel w powder coat finish Motors ebm motor w backward curved blades Filters 2 ...

Page 5: ...anufactured to withstand extreme temperature variations FILTERS Two 2 Washable Electrostatic Panel Type Air Filters they are 8 5 216mm x 15 380mm x 0 125 3mm PORT SELECTION Reversing Unit Units are shipped indicating airflow see Dimensions Airflow on next page These ports can be selected on site by the installer and changed around as needed IE Exhaust Air From Building could be changed to Air From...

Page 6: ...T MOISTURE TRANSFER Submitted by Date Qty Model Comments Project Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 25 50 75 100 125 150 175 200 cfm l s n x 0 47 in w g Pa n x 248 Net Supply Net Exhaust Specifications and Ratings Model SER 1504N Total assembled weight 45 lbs Cabinet 24 ga steel w powder coat finish Motors ebm motor w backward curved blades Filters 2 washable ...

Page 7: ...y energy recovery core configured for an efficient cross flow ventilation Core is 12 x 12 305 x 305 mm with a 15 380 mm depth Cores are manufactured to withstand extreme temperature variations FILTERS Two 2 Washable Electrostatic Panel Type Air Filters they are 11 75 298mm x 15 380mm x 0 125 3mm CONTROLS External three 3 position Low Stand By Medium rocker switch that will offer continuous ventila...

Page 8: ...ICIENCY APPARENT SENSIBLE EFFECTIVENESS NET MOISTURE TRANSFER Submitted by Date Qty Model Comments Project Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 25 50 75 100 125 150 175 200 cfm l s n x 0 47 in w g Pa n x 248 Net Supply Net Exhaust Specifications and Ratings Model SER 2004 Total assembled weight 61 lbs Cabinet 22 ga steel w powder coat finish Motors ebm motor w b...

Page 9: ...manufactured to withstand extreme temperature variations FILTERS Two 2 Washable Electrostatic Panel Type Air Filters they are 11 75 298mm x 15 380mm x 0 125 3mm PORT SELECTION Reversing Unit Units are shipped indicating airflow see Dimensions Airflow on next page These ports can be selected on site by the installer and changed around as needed IE Exhaust Air From Building could be changed to Air F...

Page 10: ...NCY APPARENT SENSIBLE EFFECTIVENESS NET MOISTURE TRANSFER Submitted by Date Qty Model Comments Project Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 25 50 75 100 125 150 175 200 cfm l s n x 0 47 in w g Pa n x 248 Net Supply Net Exhaust Specifications and Ratings Model SER 2004N Total assembled weight 61 lbs Cabinet 22 ga steel w powder coat finish Motors ebm motor w back...

Page 11: ... cross flow ventilation Cores are 12 x 12 305 x 305 mm with a 11 34 288 mm depth Cores are manufactured to withstand extreme temperature variations and material is Flame proof paper and polyester based synthetic paper FILTERS Four 4 Washable Electrostatic Panel Type Air Filters they are 11 75 298mm x 11 4 290mm x 0 125 3mm CONTROLS External three 3 position Low Stand By Medium rocker switch that w...

Page 12: ...roject Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 0 50 100 150 200 250 300 350 Net Supply Net Exhaust cfm l s n x 0 47 in w g Pa n x 248 Specifications and Ratings Model SER 3204D 2 access doors Total assembled weight 80 lbs Cabinet 22 ga steel w powder coat finish Motors ebm motor w backward curved blades Filters 4 washable electrostatic filters 11 75 298mm x 11 4 290mm x ...

Page 13: ...with a 11 34 288 mm depth Cores are manufactured to withstand extreme temperature variations and material is Flame proof paper and polyester based synthetic paper FILTERS Four 4 Washable Electrostatic Panel Type Air Filters they are 11 75 298mm x 11 4 290mm x 0 125 3mm PORT SELECTION Reversing Unit Units are shipped indicating airflow see Dimensions Airflow on next page These ports can be selected...

Page 14: ...ments Project Location Architect Engineer Contractor 0 0 2 0 4 0 6 0 8 1 1 2 1 4 0 50 100 150 200 250 300 350 Net Supply Net Exhaust cfm l s n x 0 47 in w g Pa n x 248 Specifications and Ratings Model SER 3204N Total assembled weight 80 lbs Cabinet 22 ga steel w powder coat finish Motors ebm motor w backward curved blades Filters 4 washable electrostatic filters 11 75 298mm x 11 4 290mm x 0 125 3m...

Page 15: ...ed electronic wall control wire Electronic air temperature probe gives this board accurate readings in order to minimize unnecessary defrost operation and the on board jumpers provide the user with the option of adjusting defrost time and sequence to optimize performance under abnormal conditions The defrost operation is automatic and is usually never adjusted 3 Defrost on selected models The auto...

Page 16: ...the heating season is higher than outdoor levels High humidity is a major cause of structure damage and IAQ problems such as mold and mildew 2 wire installation 4 wire installation 3 wire installation 2 wire installation EDF5 INTELLITEK MULTI FUNCTION WALL CONTROL Control multiple func tions of your Fantech ERV with one slimline wall control Two wire connection simplifies installation Use one EDF5...

Page 17: ...A Dehumidistat is ideal for use in energy efficient houses where indoor humidity during the heating season is higher than outdoor levels High humidity is a major cause of structure damage and IAQ problems such as mold and mildew This feature can be turned off when installed in climates that do not require it MAINTENANCE LIGHT When the light is on it indicates it may be time to clean unit To reset ...

Page 18: ...nd tighten 1 Place Fastening hooks on the strapping board or the floor joists 1 Install the drain nipple Installing Drain Line Units with defrost Through normal operation and during its defrost mode the ERV may produce some condensation This water should flow into a nearby drain or be taken away by a condensate pump The ERV and all condensate lines must be installed in a space where the temperatur...

Page 19: ...e outer liner which acts as a vapor barrier must be completely sealed to outer wall and the ERV using tape and or caulking A good bead of high quality caulk ing preferably acoustical sealant will seal the inner flexible duct to both the ERV port and the weatherhood prior to clamping To minimize air flow restriction the flexible insulated duct that connects the two outside weatherhoods to the ERV s...

Page 20: ...e See local building codes and practical tips To maximize airflow in the ductwork system all ducts should be kept short and have as few bends or elbows as possible Forty five degree are preferred to 90º elbows Use Y tees instead of 90º elbows whenever possible All duct joints must be fastened with screws or duct sealant and wrapped with a quality duct tape to prevent leakage Aluminum foil duct tap...

Page 21: ...o the ducting and fasten the collar to the wall or ceiling with screws 3 The Fantech grill MGE metal or PGE plastic airflow can be adjusted by rotating the inside unit It is recommended that the Grills be completely opened at first and then adjusted later as needed Attic or Garage Installation 1 Begin with the duct collar marked Exhaust Air In Slide a short piece 12 of flexible duct over the duct ...

Page 22: ...d to ensure the system will perform as intended All air movement devices have a performance curve The amount of air CFM that an ERV will deliver is directly related to the total external static pressure E S P of the system Static pressure is a measure of resistance imposed on the blower by length of duct work number of fittings used in duct work duct heater etc Fully Dedicated System new construct...

Page 23: ...s only 6 2m minimum separation recommended 18 460mm above grade minimum 3 Due to the differences in pressure between the ERV and the equipment it is being connected to the ERV s airflow must be confirmed on site using the balancing procedure found in the installation manual Unit is normally balanced on HIGH speed with furnace blower ON Outdoors Return Air 1 m 3 3 min recommended Cool Air Return Du...

Page 24: ...paration recommended 18 460 mm above grade minimum 5 Due to the differences in pressure between the ERV and the equipment it is being connected to the ERV s airflow must be confirmed on site using the balancing procedure found in the installation manual Unit is normally balanced on HIGH speed with furnace blower ON Return Air 1 m 3 3 min recommended Cool Air Return Outdoors 40 Min Ducts connection...

Page 25: ...imum 4 Due to the differences in pressure between the ERV and the equipment it is being connected to the ERV s airflow must be confirmed on site using the balancing procedure found in the installation manual Unit is normally balanced on HIGH speed with furnace blower ON Return Air 1m 3 3 min recommended Cool Air Return Outdoors 1 m 3 3 min recom mended Ducts connection may vary depending on model ...

Page 26: ...e or other manometer capable of reading from 0 to 0 25 in 0 62 Pa of water preferably to 3 digits of resolution The tube coming out of the top of the pitot is connected to the high pressure side of the gauge The tube coming out of the side of the pitot is connected to the low pressure or reference side of the gauge Insert the Pitot tube into the duct pointing the tip into the airflow For general b...

Page 27: ...rouble free use of your system Run through the system and verify the different operating modes ENERGY RECOVERY CORE FILTERS The motor The motors are factory balanced and lubri cated for life They require no maintenance The unit The inside of the unit should be vacuumed yearly Be careful not to damage any of the mechan ical components and electri cal connections CAUTION MAKE SURE UNIT IS UNPLUGGED ...

Page 28: ...ance ERV Locate the Grills high on the walls or under the baseboards install ceil ing mounted diffuser or Grills so as not to directly spill the supply air on the occupant eg Over a sofa Turn down the ERV supply speed A small duct heater 1kw could be used to temper the supply air Placement of furniture or closed doors is restricting the movement of air in the home If supply air is ducted into furn...

Page 29: ...ing THERMOSTAT TERMINALS FURNACE 24 VOLT TERMINAL BLOCK FOUR WIRE TWO WIRE heating only TWO WIRE COOLING SYSTEM HRV ELECTRONIC BOARD WIRE JOINT Caution Never connect a 120 volt AC circuit to the terminals of the Accessory Control Contacts Only use the low voltage class 2 circuit of the furnace blower control For a Furnace Connected to a Cooling System On some older thermostats energizing the R and...

Page 30: ...30 ELECTRICAL WIRING DIAGRAMS SER 1504 SER 1504N SER 2004 SER 2004N ...

Page 31: ...31 ELECTRICAL WIRING DIAGRAMS SER 3204D SER 3204N ...

Page 32: ...echnological leadership position Article 301096 Item 401455 Rev Date 020905 United States 1712 Northgate Blvd Sarasota FL 34234 Phone 800 747 1762 941 309 6000 Fax 800 487 9915 941 309 6099 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Phone 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 www fantech ca info fantech ca ...

Reviews: