4
Operating conditions
This ventilation system is designed to operate under standard humidity and temperature conditions. However, some extreme conditions may cause the
exchanger to freeze or produce an excessive amount of water condensation. This ventilation system should not be operated with an indoor humidity
above 50% in combination with an outdoor temperature below -10°C (14°F) for more than 12 continuous hours.
Residential ERV ventilation systems are not suitable for pool or spa applications.
Room classification Number of rooms
CFM (L/s)
CFM Required
Master bedroom
x 10 L/s (20 CFM)
=
Basement
yes or no
=
Bedrooms
x 5 L/s (10 CFM)
=
Living room
x 5 L/s (10 CFM)
=
Others
x 5 L/s (10 CFM)
=
Kitchen
x 5 L/s (10 CFM)
=
Bathroom
x 5 L/s (10 CFM)
=
Laundry room
x 5 L/s (10 CFM)
=
Utility room
x 5 L/s (10 CFM)
=
Total Ventilation Requirements
(add last column )
=
if yes add 10 L/s (20 CFM)
if no = 0
1 CFM = 0.47 L/s
1 L/s = 2.13 CFM
Room Count Method
DETERMINING YOUR AIRFLOW REQUIREMENT
ASHRAE method
Ventilation Air requirements
Floor area
Bedrooms
1
2
3
4
5
Ft2
m2
CFM
L/s
CFM
L/s
CFM
L/s
CFM
L/s
CFM
L/s
<500
<47
30
128
38
18
45
21
53
25
60
28
501-1000
47-93
45
21
53
24
60
28
68
31
75
35
1001-1500
94-139
60
28
68
31
75
35
83
38
90
42
1501-2000
140-186
75
35
83
38
90
42
98
45
105
49
2001-2500
187-232
90
42
98
45
105
49
113
52
120
56
2501-3000
233-279
105
49
113
52
120
56
128
59
135
63
3001-3500
280-325
120
56
128
59
135
63
143
66
150
70
3501-4000
326-372
135
63
143
66
150
70
158
73
165
77
4001-4500
373-418
150
70
158
73
165
77
173
80
180
84
4501-5000
419-465
165
77
173
80
180
84
188
87
195
91
* ASHRAE 62.2-2016 Table 4.1, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.
Bathroom:
If the HRV is going to provide the required local exhaust ventilation for each bathroom with each a continuous 20 CFM
(10 L/s), this ventilation rate can be considered as part of the whole-building ventilation rate.