Safety Precautions 

1.

 

To  ensure the success  of  the installation  be  sure to  read  the instructions and  study  the 
diagrams thoroughly before commencing. 

 
2.

 

All  electrical  work  should  only  be  undertaken  after  disconnection  of  the  power  by 
removing  fuses  or  turning  off  the  circuit  breaker  to  ensure  all  pole  isolation  of  the 
electrical supply. If you are in any doubt the services of a qualified electrician should be 
sought to ensure that all work is carried out in accordance with the I.E.E. Regulations, 
current good practice and other national and local electrical codes. 

 
3.

 

Make sure that your installation site will not allow the rotating fan blades to come into 
contact with any object and that there is a minimum clearance of 150mm (6”) from the 
blade  tip  to  the  wall  or  ceiling.  Please  note that  the  bigger  the clearance the better  the 
airflow from  your  fan  will  be.  Ensure the blades are mounted  at  a  minimum  height  of 
2.3 meters (7’6”) from the floor when the fan is installed. 

 
4.

 

The fixing point for the fan must be able to support a weight of ten times that of the net 
weight of the fan. Net weights can be found on the bottom of the unit’s box. If you are 
mounting  the  fan  to  a  ceiling  junction  box,  the  box  and  it’s  fixing  must  be  able  to 
support the moving weight of the fan and must not twist or work loose. 

 
5.

 

The fan must be earthed. 

 
6.

 

Do  not  connect  the  fan  motor  to  a  dimmer  switch.  This  may  give  an  unsatisfactory 
performance (motor hum) and cause damage to the motor. 

 
7.

 

It  is  not  recommended  that  ceiling  fans  and  gas  appliances  are  operated  in  the  same 
room at the same time. 

 
8.

 

The fan  must  be  turned  off  and  stopped  completely  before reversing the fan  direction. 
This will prevent any damage to the motor of the unit or controller (if installed). 

 
9.

 

Do not insert anything into the fan blades while the fan is operating. This will damage 
the blades and upset the balance of the unit causing the unit to wobble. 

 
10.

 

After the fan is completely installed make sure that all connections are secure   
and tight to prevent any problems. 

 
11.

 

Because  of  the  fan’s  natural  movement,  some  connections  may  loosen.  Check  the 
support connections, brackets and blade attachments twice a year to make sure they are 
all secure. If they are loose tighten with a screwdriver.    ( It is not necessary to take the 
fan down from the ceiling ) 

 
Note  :  The  important  safeguards  and  instructions  given  in  this  manual  are  not  meant  to 
cover  all  possible  conditions  and  situations  that  may  occur.    It  must  be  understood  that 
common  sense, caution and care are factors which cannot be built into any product. These 
factors must be supplied by the persons caring for and using the unit. 
 

For installation advice, or in the unlikely event of damaged or missing parts please ring: 

HELPLINE : 01959 564440 

[email protected] 

Summary of Contents for Medina

Page 1: ...MAINTENANCE WARRANTY CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION IF UNSURE CONSULT A QUALIFIED ELECTRICIAN SUITABLE FOR 220 240V 50 60hz CYCLE ELECTRICAL SUPPLY Enquiries on installing your fan please call our help line on 01959 564440 technical fantasiaceilingfans com ...

Page 2: ...t twist or work loose 5 The fan must be earthed 6 Do not connect the fan motor to a dimmer switch This may give an unsatisfactory performance motor hum and cause damage to the motor 7 It is not recommended that ceiling fans and gas appliances are operated in the same room at the same time 8 The fan must be turned off and stopped completely before reversing the fan direction This will prevent any d...

Page 3: ...on of your fan please ensure the safety precautions have been read and understood Installation Difficulties Missing or Damaged Parts If you have any difficulty in installing your fan light or if you are unfortunate enough to find that your fan has been dispatched with parts missing or damaged please contact our help line on 01959 564440 We will be very pleased to provide help or forward replacemen...

Page 4: ...4 of 20 Parts names and their relative positions ...

Page 5: ... 4 Attaching light fitting 5 Blade assembly 6 Attaching the blades The hanger bracket should be screwed on to a firm flat surface The fixing location must be able to withstand ten times the static weight of the fan If you have any doubts as to the ability of your intended fixing location to be able to withstand this loading please contact our service help line or another competent authority to adv...

Page 6: ... motor and insert the drop rod into the drop rod boss on top of the motor casing Turn gently to align the holes in the boss with those in the rod Ease the cotter pin through the boss and the rod taking care not to pinch or damage any cables Fix in place by replacing the split pin Tighten all set screws at this point This prevents the rod and the fan moving in relation to one and other It also assi...

Page 7: ...warranty IMPORTANT THIS APPLIANCE MUST BE EARTHED Ways of wiring your fan 3 Wiring Instructions Once the drop rod assembly has been fitted lift the fan up to the hanger bracket Steer the ball in from the side of the bracket and lower it into the recess of the bracket Rotate the ball around until the groove in the side of the ball aligns with the protrusion on the upper edge of the recess When alig...

Page 8: ...8 of 20 ...

Page 9: ...9 of 20 ...

Page 10: ...10 of 20 ...

Page 11: ...er the canopy up to the hanger bracket and insert the screws in the hanger bracket Tighten all the screws to ensure a good safe fixing It is important to fix the canopy properly as this offers another level of safety should anything happen to the hanger bracket Now is a good time to test that the fan operates correctly If the motor has plastic packing pieces attached then remove them now With the ...

Page 12: ...ply for the light and the blue wire is the neutral The connection is made with push together connectors When assembling the lighting attachment back onto the fan ensure there are no cables trapped between the metal surfaces Also ensure that there are serrated washers on the three screws at the bottom of the switch housing This ensures good earth continuity to the light Fit the bulbs Clip the dangl...

Page 13: ...he coarse threaded short bolts and the spring washers provided bolt the carrier bracket on to the motor Ensure the bolts are tightened firmly Be careful not to bend the carrier brackets during installation as this may result in an imbalance and induce wobble If installing more than one fan be careful not to mix the blade sets Each set is carefully manufactured to be evenly balanced mixing would br...

Page 14: ... or remote control system has been used refer to the accompanying leaflets enclosed in these systems Blade balancing Whilst every precaution is taken at the factory to ensure your fan is of the highest quality imbalance may occur This may be due to slight irregularities in the blades or blade carriers Further problems can be caused by deviating from these instructions The following procedure may h...

Page 15: ...surface up to 40 The fan will have to be installed in the drop rod style of mounting for this Remember to allow adequate clearance for the rotating blades see Safety Precaution 3 Do not forget to put the canopy on the rod before connecting the rod onto the fan Extension chain is available if the control chains are not long enough please ring the help line for further details If you are installing ...

Page 16: ... 20 Please use these pages to attach your proof of purchase as you may need it if you need to contact Fantasia in the future Don t forget to complete and return the warranty form at the back of this booklet ...

Page 17: ...by the new owner Warranty for the fan does not cover damage to the fan if it is moved from one dwelling to another during the warranty period The warranty is voided in total if the product is sold as second hand goods The following is NOT covered by warranty 1 Any damage incurred after delivery to the owner that is not caused by a fault in the products materials or workmanship damage from lightnin...

Page 18: ...18 of 20 52 132cm Medina FANTASIA DISTRIBUTION LTD Unit B The Flyers Way Westerham Kent TN16 1DE Tel 01959 564 440 Fax 01959 564 829 E MAIL info fantasiaceilingfans com ...

Reviews: