STANDARD MODE:
Is programmed to maintain the desired temperature.
Note:
The last measured spa temperature displayed is current only when the pump has been
running for at least 2 minutes.
St
will be display momentarily only when dip switch 7 is OFF.
ECONOMY MODE:
Heats the spa to the set temperature only during filter cycles.
Ec
will display solid when temperature is not current and will alternate with temperature when
temperature is current (
Ec
will only display if dip switch 7 is OFF, see pg. 9).
SLEEP MODE:
Heats the spa within 20º F (6.6º C) of the set temperature only during filter
cycles.
SL
will display solid when temperature is not current and will alternate with temperature
when temperature is current (SL will only display if dip switch 7 is OFF, see pg. 9).
PRESET FILTER CYCLES
The first filter cycle (FC) begins 6 minutes after the spa is powered up. The second filter cycle
begins 12 hours later. Filter duration is programmable for 1, 2, 3, 4, 5, 6, 7, 8 or 12 (FC) hours.
• The default filter time is 1 hour.
• To program, press
Down
or
Up
then press
Jets
. Press
Down
or
Up
to adjust
• Press
Jets
to exit programming. Pump low speed will run for the duration.
The low speed of the pump runs during filtration and the ozone generator will be enabled.
FREEZE PROTECTION
If the temperature sensors within the heater detect a drop to below 44°F (7º C), the pump will
automatically activate to provide freeze protection. The equipment stays on until 4 minutes after
the sensors detect that the spa temperature has risen to 44°F (7º C) or higher.
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control box. Contact Customer Service for assistance. Follow
all owner manual power connection instructions. Installation must be performed by a licensed
electrician and all grounding connections must be properly installed.
WARNING! DO NOT ENTER SPA IF WATER IS TOO HOT
Water is too hot.
Overheat protection heater is deactivated. Spa water temperature is above
acceptable limits. When the actual water temperature is approximately 2º F (1º C) above the
set temperature, the jet pump will stop operating to reduce (frictional) heating. If the spa water
temperature continues to rise and gets above 110º F (44ºC), the spa will go into an “OH” overheat
condition.
To Correct Condition:
1. Remove the spa’s cover and allow your spa to cool down.
2. Reduce the temperature setting.
3. When the water temperature drops below 106º F (41ºC), the spa will resume normal operation.
4. If the water does not drop below 106ºF (41ºC), contact Customer Service.
Note:
Your spas topside control panel has been designed to include:
a)
Jets
button
b)
Light
button
c)
Down
heat button
d)
Up
heat button
12
CONTROL PANEL OPERATION
LED Heat Indicator
Summary of Contents for MUSE
Page 1: ...OWNER S MANUAL PLUG PLAY EMBRACE MUSE ELUSION...
Page 26: ...NOTES...
Page 27: ......
Page 28: ...PART 303343 REV B 4 12...