Fanimation Windpointe FP7500 Manual Download Page 4

 

Tools Needed for Assembly 

(Not Included)

Materials

     WARNING

Before assembling your ceiling fan, refer to section on 

proper method of wiring your fan (page 9). If you feel you 

do not have enough wiring knowledge or experience, have

your fan installed by a licensed electrician.

This manual is designed to make it as easy as possible for you to assemble,

install, operate and maintain your ceiling fan

• One Phillips head screwdriver

• One ¼˝ blade screwdriver

• One stepladder

• One wire stripper

Wiring outlet box and box connectors must be of type

required by local code. The minimum wire would be a 3-

conductor (2-wire with ground) of the following size:

nstalled ire ength

ire i e

p to   ft

 ft

Unpacking Instructions

1. 

Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

WARNING

Do not install or use fan if any part is damaged or missing. This product is designed to use only those parts supplied with 

this product and/or any accessories designated specifically for use with this product by Fanimation. Substitution of parts 

or accessories not designated for use with this product by Fanimation could result in personal injury or property damage. 

Contact your retail store for missing or damaged parts.

For your convenience, check-off each step. As each step is completed, place a check mark. This will ensure that all steps have been 

completed and will be helpful in finding your place should you be interrupted.

4

NOTE: Place the parts from the loose parts bags in a small 

container to keep them from being lost. If any parts are

missing, contact your local retailer. 

Switch Cup Housing/

Adapter Assembly (1)

Blade Holder Set (1)

Blade Holder 

Cover Set (1)

Blade Set (Not Included)

 

Hanger Bracket

Assembly (1) 

Motor Coupling

Cover Assembly (1)

Hardware Bags

Motor Assembly (1)

Downrod/Hanger Ball Assembly (1)
– Downrod (1)

– Hanger Ball (1)

– Set Screw (1)

– Hairpin Clip (1)

– Clevis Pin (1)

– Pin (1)

1/4"-20

Screws with Lockwashers

(11)

3/16"-24 

Carriage Head Nuts

(11)

3/16"-24

Washer Head Screws

(11)

Ceiling Canopy (1)

5/32˝ 

Threaded Rods

(2)

5/32˝ 

Lockwashers

(2)

Knurled Knobs

(2)

Pull Chain Coupler

(1)

Safety Cable Kit

Safety Cable

(1)

Flat Washer,

Stainless Steel

(1)

Lag Bolt

(1)

Wire Connectors

(4)

Fan Fob

(1)

Cable Clamp

(1)

Summary of Contents for Windpointe FP7500

Page 1: ...EST Monday Friday Date Code Purchase Date Net Weight 23 26 lbs 10 55 kgs ATTACH YOUR RECEIPT HERE AND REGISTER YOUR FAN AT FANIMATION COM READ AND SAVE THESE INSTRUCTIONS MOTOR ASSEMBLY MODEL MA7500 BLADE SOLD SEPARATELY For best and quickest service please provide date code You can find the date code on the carton or top of fan housing WINDPOINTE CEILING FAN ...

Page 2: ... ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The fan base must be securely mounted and capable of reliably supporting at least 50 lbs See page 5 of owner s manual for support requirements Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least...

Page 3: ...Fanimation 7 Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty 8 Under no circumstances may a fan be returned without prior authorization from Fanimation The receipt of purchase must accompany authorized returns and must be sent freight prepaid to Fanimation The fan to be returned must be properly packed to avoid damage i...

Page 4: ...ed specifically for use with this product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage Contact your retail store for missing or damaged parts For your convenience check off each step As each step is completed place a check mark This will ensure that all steps have been completed and will...

Page 5: ...our Fanimation Retailer for optional mounting accessories Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 HZ 15 Amp Circuit Electrical code requires use of a fan rated outlet box to support the extra weight and motion associated w...

Page 6: ...ire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Figure 3 CEILING JOIST CEILING OUTLET BOX To reduce the risk of fire electric shock or personal injury mount to outlet box marked acceptable for fan support of 15 9 kg 35 lbs or less and use mounting screws provided with the outlet box M...

Page 7: ... open side facing up Figure 3 5 Reinstall the hanger ball Figure 1 on the downrod as follows Route the three 80 wires and cable through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin Securely tighten the setscrew in the hanger ball A loos...

Page 8: ...bracket grounding wire and safety cable are pulled through the downrod between the hanger bracket and the outlet box so that electrical connections can be made later 4 Carefully lift the fan and seat the downrod hanger ball assembly onto the hanger bracket that was just attached to the outlet box Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 4 5 Attach the safety...

Page 9: ...lectrician for advice as it must be grounded for safe operation Option A NOTE If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician How to Wire Your Ceiling Fan WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring Figure 1 WARNING Check to see that all connection...

Page 10: ...d wire available NOTE If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until the blades are in place Noise and motor damage could result 2 After c...

Page 11: ...he canopy housing and not pinched between the housing and the ceiling 1 Screw in two threaded rods into the hanger bracket Figure 1 NOTE The threaded rods in the hanger bracket serves as guides for easier installation 2 Securely attach the canopy housing to the hanger bracket using the external lockwashers and knurled knobs supplied with your fan Figure 2 Lockwashers 2 Knurled Knobs 2 X 2 X 2 X 2 ...

Page 12: ...es assembled may result in damage to the fan blades To reduce the risk of personal injury do not bend the blade holders when installing balancing the blades or cleaning the fan Do not insert foreign objects in between the rotating blades WARNING INSTALLATION NOTE 5 Attach assembled blades and blade holders to the motor hub using the provided screws Figure 3 6 Make sure the screws securing the blad...

Page 13: ...t bracket and tighten three screws Securely attach the 9 pin switch cup connector to wiring harness socket within adapter assembly Figure 6 10 Assemble the housing switch cup onto the assembled adapter with three screws Figure 7 11 Install the fan fob and pull chain coupler Figure 8 12 Restore power and your fan is now wired to be turned on and off from the fan pull chain speed control Figure 8 WA...

Page 14: ...and wait for the blades to stop turning Slide the reverse switch on the switch cup assembly to the opposite position and turn fan on again Figure 3 Reverse Switch Information Season Rotation Direction Switch Position Summer Counterclockwise Left Winter Clockwise Right Periodic cleaning of your new ceiling fan is the only maintenance necessary When cleaning use only a soft brush or lint free cloth ...

Page 15: ...xternal Lockwashers 2 Knurled Knobs 2 Pull Chain Coupler Fan Fob Wire Connectors 4 Blade Mounting Hardware Bag Containing 3 16 24 Washer Head Screws 11 3 16 24 Carriage Head Nuts 11 Blade Holder Mounting Hardware Bag Containing 1 4 20 Phillips Head Screws with Lock Washers 11 Safety Cable Kit Bag Containing Ceiling Support Cable with Clamp Lag Bolt 3 8 x 2 Flat Washer Blades Not Included Part FP75...

Page 16: ...ration shown is not to scale or its actual configuration may vary Product parts are subject to change without notice WINDPOINTE Model FP7500 Exploded View Illustration 9 5 4 3 1 2a 2b 2c 2d 2 6 8 7 Blades Optional 16 ...

Page 17: ...her or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew in downrod support is loose 2 Setscrew in downro...

Page 18: ...2021 04 V 01 Copyright 2021 Fanimation 10983 Bennett Parkway Zionsville IN 46077 Phone 888 567 2055 Outside U S 317 733 4113 FAX 866 482 5215 FANIMATION COM ...

Page 19: ...E SU RECIBO AQUÍ Y REGISTRE SU VENTILADOR EN FANIMATION COM LEA Y GUARDE ESTAS INSTRUCCIONES Para ofrecer un servicio rápido y de calidad por favor suministre el código de fecha Puede encontrar el código de fecha en el paquete o en la parte superior de la carcasa del ventilador Peso neto 10 55 kgs 23 26 lbs MODELO DE UNIDAD DEL MOTOR MA7500 ASPAS SE COMPRA POR SEPARADO VENTILADOR DE TECHO WINDPOIN...

Page 20: ...este producto podría sufrir lesiones personales o dañar el ventilador ADVERTENCIA Para reducir el riesgo de lesiones personales no doble los soportes de aspas borde o soporte de aspas al instalar los soportes balancear las aspas o limpiar el ventilador No coloque objetos extraños entre las aspas del ventilador en funcionamiento ADVERTENCIA para reducir el riesgo de incendios o descargas eléctricas...

Page 21: ...ucto 9 Se entiende que las reparaciones y las sustituciones son el único recurso disponible de Fanimation No existe ninguna otra garantía expresa o implícita Por la presente Fanimation niega todas las garantías implícitas que incluyen entre otras la comerciabilidad y la aptitud para determinado fin hasta donde la ley lo permita Algunos estados no permiten limitaciones sobre las garantías implícita...

Page 22: ...o 1 Verifique que haya recibido las siguientes piezas NOTA Si no está seguro de la descripción de una pieza consulte la ilustración del despiece Unidad de la caja del adaptador del interruptor 1 Juego de aspas No incluido Unidad del motor 1 Tornillos 3 16 24 11 Unidad del soporte de suspensión 1 Unidad del barral de la semiesfera 1 Varilla 1 Bola colgante 1 Tornillo de fijación 1 Clip de horquilla...

Page 23: ...a un flujo de aire óptimo Consulte en su tienda minorista de Fanimation para obtener accesorios de montaje opcionales Apague el ventilador cuando no se encuentre en la habitación Los ventiladores son para refrescar a la gente no a las habitaciones Si la habitación está vacía apague el ventilador de techo para ahorrar energía Su nuevo ventilador de techo requiere una línea de suministro eléctrico c...

Page 24: ...oporte de lámparas no son aptas para soporte de ventiladores y es posible que deban reemplazarse Consulte a un electricista calificado si tiene dudas ADVERTENCIA Apagar el interruptor de pared no es suficiente Para evitar posibles descargas eléctricas asegúrese de que la electricidad esté desconectada en la caja de fusibles principal antes de realizar la instalación eléctrica Toda instalación eléc...

Page 25: ...estra con el lado abierto apuntando hacia arriba Figura 3 5 Vuelva a colocar la semiesfera Figura 1 en el barral como se indica a continuación Pase los tres cables de 2 m 80 y el cable de seguridad a través de la semiesfera Pase el pasador a través de los dos orificios en el barral y alinee la semiesfera de modo que el pasador quede atrapado en la ranura de la parte superior de la misma Empuje la ...

Page 26: ...erra para un funcionamiento seguro 2 Fije adecuadamente el soporte colgante a la caja de empalme del techo que sea aceptable para el soporte del techo NOTA el cable de soporte para techo no se puede asegurar solamente a la caja de conexiones se debe asegurar directamente a la viga de techo o miembro estructural con el tornillo de cabeza cuadrada de 3 8 x2 y la arandela plana Figura 3 ADVERTENCIA P...

Page 27: ... conexión a tierra del soporte de suspensión y el cable de seguridad hayan atravesado el barral entre el soporte de suspensión y la caja de conexiones de modo que más tarde se pueda realizar la instalación eléctrica 5 Fije el cable de seguridad al cable de soporte para techo Deslice la abrazadera de cables por el cable de seguridad del ventilador Pase el extremo del cable a través del aro que form...

Page 28: ...ores de cable Aditamentos utilizados X 3 Figura 1 Figura 2A Principal Caja De Fusibles Conductor verde del suministro puesta a tierra Conductor verde de la abrazadera para colgar puesta a tierra Conductor verde de la bola para colgar puesta a tierra Conductor blanco del suministro Caja de salida homologada Suministro eléctrico Conductor negro del suministro Conductor azul del ventilador Conductor ...

Page 29: ...e no tiene suficientes conocimientos o experiencia en cableado eléctrico pida a un electricista autorizado que instale su ventilador 2 Una vez haya hecho las conexiones teniendo cuidado de no pillar los cables Poniendo los cables blancos y verdes a un lado de la caja y los negros hacia el otro lado Coloque los cables hacia arriba y empújelos cuidadosamente hacia dentro de la caja de la toma de cor...

Page 30: ...ando las arandelas externas y los pomos moleteados suministrados con su ventilador Figura 2 ADVERTENCIA Para evitar posibles incendios o descargas eléctricas asegúrese de que los cables eléctricos se encuentren completamente adentro de la cubierta del capuchón y de que no estén aprisionados entre la cubierta y el techo Figura 1 Figura 2 Arandelas 2 Pomos moleteados 2 X 2 X 2 X 2 Aditamentos utiliz...

Page 31: ... funcionamiento NOTA DE INSTALACIÓN No conecte las aspas hasta que el ventilador esté totalmente instalado Instalar el ventilador con las aspas colocadas podría ocasionar daños en las mismas Cómo ensamblar las aspas del ventilador de techo y la caja del interruptor 5 Ajuste las aspas ensambladas y los soportes al buje del motor con los tornillos y las arandelas de seguridad suministrados Figura 3 ...

Page 32: ...hufe del mazo de cables dentro del adaptador Figura 6 10 Instale el soporte del interruptor de la carcasa en el adaptador ensamblado mediante los tres tornillos Figura 7 ADVERTENCIA La etiqueta de color de estos dos conectores debe corresponder mutuamente Unidad de interruptor adaptador Figura 7 11 Instale el llavero de ventilador y acoplador de cadena de tirada Figura 8 12 Vuelva a conectar la el...

Page 33: ...sar ruido y daños 2 Verifique el funcionamiento del ventilador jalando suavemente del acoplador de la cadena del tirador del ventilador Figura 2 1 ª tirada 2 ª tirada 3 ª tirada 4 ª tirada Secuencia de funcionamiento de la cadena del tirador del ventilador Alta Media Baja Apagado 3 Si desea que el flujo de aire corra en la dirección opuesta apague el ventilador y espere hasta que las aspas dejen d...

Page 34: ...impieza los mismos deben evitarse para prevenir daños en el acabado Mantenimiento PRECAUCIÓN No utilice solventes para limpiar el ventilador de techo Podrían dañar el motor o las aspas y ocasionar posibles descargas eléctricas Se recomienda limpiar el polvo de las aspas periódicamente Lo mejor es utilizar un plumero Evite usar agua productos de limpieza o trapos ásperos que pueden combar o dañar l...

Page 35: ...za redonda de 3 16 24 11 Bolsa de accesorios para el montaje de los soportes de aspas que contiene Tornillos de cabeza tipo Phillips de 1 4 20 con arandelas de seguridad 11 Kit de cable de seguridad que contiene Cable de soporte para techo con abrazadera Tornillo de cabeza cuadrada de 3 8 x 2 Arandela plana Aspas No incluido Pieza N º FP7500 APG610BL ADR1 6 PG165 AP1115 AMA53 AP5005 501 AP5006 5 A...

Page 36: ...lo N º FP7500 Ilustración del despiece NOTA La ilustración que se muestra no está hecha a escala y su c guración real y o terminación puede variar WINDPOINTE 9 5 4 3 1 2a 2b 2c 2d 2 6 8 7 Aspas Opcional 36 ...

Page 37: ...CAUCIÓN Asegúrese de que el suministro principal de electricidad esté desconectado 5 Algunos motores de ventilador son sensibles a las señales de los controles de velocidad de estado sólido variables Los controles de estado sólido no son recomendables Escoja un método de control alternativo 6 Ajuste bien los tornillos 7 Asegure bien los tornillos de fijación 3 EL VENTILADOR OSCILA EN EXCESO 1 El t...

Page 38: ...1 Copyright 2021 Fanimation Visite nuestro sitio Web en www fanimation com 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 ...

Reviews: