Fanimation Vetricco FP3120 Series Owner'S Manual Download Page 9

9

Figure 1

3.

 Securely attach plugs from motor to sockets on Downlight 

Socket Plate Assembly (Figure 3)

Installing the Lower Housing Assembly

1.

 Loosen four screws and remove one screw from support 

flange. (Figure 1).

Figure 2

Figure 3

2.

  Be sure to “square” or line up the corners of the Adapter 

Plate with the corners of the motor housing.  Securely 

attach the Adapter Plate to the motor shaft by tightening 

the screws. (Figure 2)

CAUTION

To avoid possible electrical shock, be sure electricity is 

turned off before installing downlight assembly.

Summary of Contents for Vetricco FP3120 Series

Page 1: ...D AND SAVE THESE INSTRUCTIONS Model No FP3120 The Vetricco Ceiling Fan VETRICCO Fan Satin Nickel Finish shown with Plastic Blade Set VETRICCO Fan Glossy Black Finish shown with Plastic Blade Set Net Weight 17 1 kg 38 lbs ...

Page 2: ... on implied warranties Fanimation will not be liable for incidental consequential or special damages arising out of or in conjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or...

Page 3: ...nlight Socket Plate Assembly Lower Glass Housing Cover Hardware Bags Fan Motor Housing Assembly Downrod Hanger Ball Assembly Hanger Bracket One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy Adapter Plate Plastic Blades C26 Remote Control Hardware bag Seven 20 x 14mm blade holder to fan motor hub screws Thirteen 3 16 2...

Page 4: ... four wires Route the wires and support cable through the Downrod If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING ...

Page 5: ...pin Securely tighten the setscrew in the Hanger Ball A loose setscrew could create fan wobble 7 While pulling up on the hanger ball securely tighten the two 3 16 24 x 13mm setscrews in the downrod support Figure 3 NOTE The setscrews must be properly installed as described above or fan wobble could result 8 Slide the Motor Coupling Cover down until it touches the top of the Housing Figure 4 5 Insta...

Page 6: ... Figure 3 Downrod Hanger Ball Assembly Attach Safety Cable to Ceiling Support Cable Tab NOTE Supply wires and fan wires omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the building structure Figure 2 You will first drill a pilot ...

Page 7: ...Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until the blades is in place Noise and fan damage could result ORANGE FOR UP LIGHT 1 Setting the Code The remote unit has 16 different code combinations To prevent possible interference from or to other remote units such as garage door o...

Page 8: ...t serve as guides for easier installation 2 Securely attach the Canopy Housing to the Hanger Bracket using the external lockwashers and knurled knobs supplied with your fan Figure 1b Figure 1a Figure 1b NOTE Supply wires and fan wires omitted for clarity NOTE This step is applicable after the neccessary wiring is completed see page 7 Screw 2 per blade holder Figure 1 Blade Holder WARNING To avoid ...

Page 9: ...remove one screw from support flange Figure 1 Figure 2 Figure 3 2 Be sure to square or line up the corners of the Adapter Plate with the corners of the motor housing Securely attach the Adapter Plate to the motor shaft by tightening the screws Figure 2 CAUTION To avoid possible electrical shock be sure electricity is turned off before installing downlight assembly ...

Page 10: ...the Downlight Socket Plate Assembly Figure 5 6 Securely attach Lower Glass by tightening Final Glass Fasteners 4 supplied with the fan Don t overtighten Figure 6 7 You have now completed the assembly of your ceiling fan Restore electrical power INSTALLATION NOTE Be sure to line up the curved slotted holes located on both Lower Housing Support Plates Figures 4 5 Purpose of these holes are for the c...

Page 11: ...rasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the Plastic blades is recommended A feather duster will work best Avoid using water cleansers or harsh rags which can warp and ruin the finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shoc...

Page 12: ...ion Set of 3 AP32225CH 11 Plastic Blade Set of 3 AP31210 12 Support Cable Bag Containing HDWFP3120 Ceiling Support Cable Cable Clamp Flat Washer Lag Bolt 3 8 x 2 Hardware Bag Containing 5 32 Threaded Rods 2 5 32 External Lockwasher 2 Knurled Knobs 2 Screw with spring washer 5 32 32 x 8 mm 4 Final Glass Fastener 4 Final Rubber Glass Sleeve 4 Wire Connectors 4 Blade Holder Mounting Hardware Bag Cont...

Page 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary The Vetricco FP3120 Exploded View 4 1 Figure 1 3 2a 8 12 ref 7 6 5 14 10 11 2b 2c 2d 2 13 12 Reversing Switch 9 ...

Page 14: ...the motor flywheel are tight 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securel...

Page 15: ......

Page 16: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 08 ...