10
Operating Instructions – Rotary Switch
1.
Select the desired airflow located on the fan motor
assembly by rotating clockwise. (Figure 1)
• 1st position – high fan speed
• 2nd position – medium fan speed
• 3rd position – low fan speed
• 4th position – fan o
ff
Figure 1
▲
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan until the blades is in place. Noise and fan damage
could result.
How to Wire Your Wall Control
Installing the Canopy Housing
1.
Securely attach the Canopy Housing to the Hanger
Bracket using the two previously removed screws.
(Figure 1)
Figure 1
NOTE: This step is applicable after the necessary wiring
is completed.
▲
WARNING
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the canopy housing
and not pinched between the housing and the ceiling.
Figure 2
▲
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan until the blades are in place. Noise and fan damage
could result.
•
Attach wall control unit to outlet box using the two
6-32 screws provided.
• Attach face plate to the wall control.