background image

.

1.   

Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.

2.   

Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such 

as a tag, to the service panel.

3.   

Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the fan before 

servicing.

4.   

Do not insert anything into the fan blades while the fan is operating.

5.   

Do not operate reversing switch until fan blades have come to a complete stop.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Additional Safety Instructions

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   

To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.   

All wiring must satisfy National (ANSI/ NFPA) Electrical Codes.  Use the National Electrical Code if Local Codes do not exist.  The 

ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a 

licensed electrician.

3.   

The fan base must be securely mounted and capable of reliably supporting at least 100 lbs.  Outlet boxes are not acceptable for fan 

support.  See page 5 of owner’s manual for support requirements.  Consult a qualified electrician if in doubt.

4.   CAUTION:

  To reduce the risk of personal injury, mount the fan base to floor or structural member using the hardware provided with 

your fan.

5.   

The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.   

Follow the recommended instructions for the proper method of wiring your fan.  If you do not have adequate electrical knowledge or 

experience, have your fan installed by licensed electrician.

WARNING:

  To avoid fire, shock or injury, do not use a control not specifically approved for this fan.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 

damage.

WARNING:

  To reduce the risk of personal injury, do not bend the blade flange (blade holder) when installing, balancing, or cleaning the 

fan.  Do not insert foreign objects in between rotating fan blades.

Table of Contents

Unpacking Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

How to Set and Operate C20 Remote Control  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

How to Set and Install Your SW50 Switch Cap Receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

How to Put Your Floor Fan Together. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Mounting the Fan Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Blade Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Trouble Shooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Exploded-View Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1.   LIMITED LIFETIME MOTOR WARRANTY

 - If any part of your fan motor fails, due to a defect in materials or workmanship during 

the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned 

to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

2.   ONE YEAR MOTOR LABOR WARRANTY

 - If your fan motor fails at any time within one year from the original purchase, due to 

defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 

will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

3.   

If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 

will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

4.   

Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, 

tarnishing, or peeling.

5.  

This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 

heat or humidity, or as a result of any modification to the original product.

6.   

All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 

or Fanimation.

7.   

Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

8.   

Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-

company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid 

damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

9.   

It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 

implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 

fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation 

will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, 

except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 

from state to state.

10. 

A certain amount of wobble is normal and should not be considered a problem or a defect.

Summary of Contents for Pedestal FP900

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP900 The Pedestal Floor Fan Net Weight 45 lbs...

Page 2: ...tenance 6 Blade Cleaning 6 Trouble Shooting 7 Parts List 8 Exploded View Drawing 9 1 LIMITED LIFETIME MOTOR WARRANTY If any part of your fan motor fails due to a defect in materials or workmanship dur...

Page 3: ...box connectors must be of type required by local code The minimum wire would be a 3 conductor 2 wire with ground of the following size NOTE Place the parts from the loose parts bags in a small contain...

Page 4: ...th SW50 Switch Cap Control Receiver supplied with fan Figure 3 Figure 2 9V Battery Remote Transmitter Unit Detail Receiver Unit Detail Be sure the electricity to the fan is turned off Setting the Code...

Page 5: ...ctrical wiring and mounting of your fan Do not connect fan blades until the fan is completely in stalled Installing the fan with blades assembled may re sult in damage to the fan blades INSTALLATION N...

Page 6: ...lder on a flat surface with the inside of the blade holder facing up This is the side with the threaded posts and pitched foot Figure 6 2 Position the palm leaf or the woven bamboo blade over the blad...

Page 7: ...operating 2 Check to make sure all screws in motor housing are snug not over tight 3 Check to make sure the screws which attach the fan blade holders to the motor flywheel are tight 4 Check to make su...

Page 8: ...FANI1406 7 Socket Cap Screw 5 16 24 x 2 FASOCK908 8 Collector 2 P514 9 Long Leg 3 P508 10 Hex Head Bolt 20 x 1 Black 6 FAHEX312 11 Flat Washer Black 9 FAWASH716 12 Hex Head Bolt 20 x 1 Black 3 FAHEX30...

Page 9: ...wn is not to scale or its actual con guration may vary wires partially removed for clarity 9 Figure 8 Exploded View The Pedestal FP900 Side B Side A 20 19 18 13 14 12 10 10 11 8 11 3 7 24 1 2 23 5 6 7...

Page 10: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2004 Fanimation 2004 02...

Reviews: