4

Ceiling

Ceiling

Joists

Figure 1

WARNING

To  avoid  fire  or  shock,  follow  all  wiring  instructions 
carefully.    Any  electrical  work  not  described  in  these 
instructions should be done or approved by a licensed 
electrician.

WARNING

Turning  off  wall  switch  is  not  sufficient.

To  avoid 

possible  electrical  shock,  be  sure  electricity  is  turned 
off at the main fuse box before wiring.  All wiring must 
be in accordance with National and Local codes and the 
ceiling  fan  must  be  properly  grounded  as  a  precaution 
against possible electrical shock.

Electrical and Structural Requirements

Energy Efficient Use of Ceiling Fans

Ceiling fan performance and energy savings rely 
heavily on the proper installation and use of the ceiling 
fan. Here are a few tips to ensure efficient product 
performance.

Choosing the Appropriate Mounting Location

Ceiling fans should be installed, or mounted, in the middle 
of the room and at least 7 feet above the floor and 18 
inches from the walls. If ceiling height allows, install the fan 
8 - 9 feet above the floor for optimal airflow. Consult your 
Fanimation Retailer for optional mounting accessories.

Turn Off When Not in the Room

Ceiling fans cool people, not rooms. If the room is 
unoccupied, turn off the ceiling fan to save energy.

Using the Ceiling Fan Year Round
Summer Season:

Use the ceiling fan in the counter-

clockwise direction. The airflow produced by the ceiling 
fan creates a wind-chill effect, making you “feel” cooler. 
Select a fan speed that provides a comfortable breeze, 
lower speeds consume less energy.

Winter Season:

Reverse the motor and operate the ceiling 

fan at low speed in the clockwise direction. This produces 
a gentle updraft, which forces warm air near the ceiling 
down into the occupied space.Remember to adjust your 
thermostat when using your ceiling fan - additional energy 
and dollar savings could be realized with this simple step!

2

˝

 x 4

˝

Outlet
Box

WARNING

To  reduce  the  risk  of  fire,  electrical  shock,  or  personal 
injury,  mount  fan  to  outlet  box  marked  acceptable  for 
fan support of 15.88 kg (35 lbs) or less. Use screws 
supplied with outlet box. Most outlet boxes commonly 
used for support of light fixtures are not acceptable for 
fan support and may need to be replaced.  Consult a 
qualified electrician if in doubt. 

Your new ceiling fan will require a grounded electrical
supply line  of  120 volts  AC,  60 Hz, 15 amp  circuit.
The outlet box must be securely anchored and
capable of withstanding  a  load of at least 50 lbs.

Figure  1

depicts different structural configurations

that may be used for mounting the outlet box.

Summary of Contents for FP7954OB

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP7954OB Net Weight 10 4 kg 22 9 lbs Wet Location Model The Crestford Ceiling Fan...

Page 2: ...se of Ceiling Fans 4 Electrical and Structural Requirements 4 How to Assemble Your Ceiling Fan 5 How to Hang Your Ceiling Fan 6 How to Wire Your Ceiling Fan 7 Installing the Canopy Housing 7 8 How to...

Page 3: ...oduct and or any accessories designated specifically for use with this product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation could result in...

Page 4: ...ooms If the room is unoccupied turn off the ceiling fan to save energy Using the Ceiling Fan Year Round Summer Season Use the ceiling fan in the counter clockwise direction The airflow produced by the...

Page 5: ...od support Figure 4 WARNING It is critical that the clevis pin in the downrod support is properly installed and the set screws and nuts are securely tightened Failure to do so could result in the fan...

Page 6: ...seat tab in groove could cause damage to electrical wires and possible shock or re hazard WARNING To avoid possible shock do not pinch wires between the hanger ball assembly and the hanger bracket 1 S...

Page 7: ...Supply White Wire from Fan Blue Wire from Fan Green Wire Ground from Hanger Ball Black Wire from Fan White Wire from Supply Figure 14 3 After splicing and making the wire connections the wires should...

Page 8: ...bottom edge of the blade is fully seated against the blade holder With a Phillips screwdriver tighten 8 32 x 8 mm Truss head screws and flat washers to secure the blade to the blade holder Figure 19 D...

Page 9: ...ng Motor Assembly 10 32 x 3 8 Screws 2 per assembly Figure 21 5 Remove one of the three screws in the motor assembly Slightly loosen the remaining two screws Assemble the adapter switch housing to the...

Page 10: ...her and nut Thread the fan pull chain through the hole in the side of trim cover and let light pull chain into the center hole of trim cover Align the holes in the trim cover and glass then thread the...

Page 11: ...on and turn fan on again Figure 30 Reverse Switch Information Season Rotation Direction Switch Position Summer Counter Clockwise Right Winter Clockwise Left Reversing Switch Maintenance 1 Periodic cle...

Page 12: ...Tighten screws securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade holders to motor flywheel are loose 4 Wire connectors inside housing rattling 5 Screws...

Page 13: ...4 Pull Chain Kit Light 8 32 x 8 mm Truss Head Screw 16 Flat Washer 16 8 32x3 4 Junction Box Screws Flat Washer 12 x 5 x1 mm Stainless Steel 2 Stainless Steel 2 Loose Hardware Bag Blade Holder Mountin...

Page 14: ...Exploded View NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without notice Figure 1 14 14 14 13 1 14 14 14 2 3 4 5 6 7 12 11 8 9...

Page 15: ...Copyright 2012 Fanimation 2012 06 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Page 16: ...Modelo lugar h medo The Crestford Ventilador de techo Peso neto 10 4 kg 22 9 lbs Modelo N FP7954OB MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES...

Page 17: ...pieza de la unidad desconecte la electricidad en el panel de servicio y bloquee los 2 medios de desconexi n del mismo para evitar que se active accidentalmente Si no se pueden bloquear los medios de d...

Page 18: ...sto se asegurar de completar todos los pasos y podr saber desde d nde retomar si fuera interrumpido ADVERTENCIA No instale ni utilice el ventilador si falta alguna pieza o si hay piezas da adas Este p...

Page 19: ...en menos energ a En invierno Invierta el motor y haga funcionar el ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga a...

Page 20: ...interior Figura 4 Es fundamental que instale correctamente el pasador de horquilla en el soporte de la varilla y que ajuste firmemente los tornillos de fijaci n y las tuercas El incumplimiento de dic...

Page 21: ...ra para colgar debe estar bien asentada contra la caja de salida Si la caja de salida est empotrada retire el panel hasta que la abrazadera haga contacto con la caja Si la abrazadera y o la caja de sa...

Page 22: ...tor con conexi n a tierra No opere el ventilador hasta que las aspas est n instaladas Podr a ocasionar ruidos y da os al motor ADVERTENCIA Negro Cable verde conexi n a tierra Cable de ventilador negro...

Page 23: ...llos de reborde de la abrazadera para colgar mediante el mecanismo de seguro por giro del chavetero Figura 16 Cubierta para el tornillo del capuch n C mo ensamblar los Blades y kit de luz Topes de Gom...

Page 24: ...tos extra os entre las aspas del ventilador en funcionamiento ADVERTENCIA NOTA Revise peri dicamente las piezas de los 4 Fije los soportes de aspas al volante mediante los tornillos de 10 32 x 3 8 a t...

Page 25: ...el orificio del lateral de la carcasa tapizada y el cristal permitiendo que dicha cadena se coloque en el orificio central de la carcasa tapizada Alinee los orificios de la carcasa y el cristal introd...

Page 26: ...a posici n contraria y vuelva a encender el ventilador Figura 30 Informaci n sobre el interruptor de reversa Temporada Verano Invierno Direcci n de rotaci n En direcci n de las manecillasdel reloj En...

Page 27: ...ste bien los tornillos 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijaci n y la tuerca del soporte de barral est n flojos 2 El tornillo de fijaci n en la unidad del barral de la semiesfera est...

Page 28: ...s de 4 Kit de balanceo Cadena del ventilador Acoplador de la cadena Cinta de la cadena 10 32x3 8 Tornillos de cabeza Phillips con arandelas de seguridad 11 N de Ref Descripci n Pieza N Modelos N FP795...

Page 29: ...29 Figura 1 14 14 14 13 1 14 14 14 2 3 4 5 6 7 12 11 8 9 10 The Crestford Modelo FP7954OB Despiece NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar...

Page 30: ...12 Fanimation 2012 06 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Reviews: