Trouble

Probable Cause

Suggested Remedy

1.  FAN  WILL  NOT  START

1.

  Fuse or circuit breaker blown.

2.

  Loose power line connections to the fan, or loose 

switch wire connections in the switch housing.

3.

  Reversing switch in neutral position.

4.

  Dead battery in remote control.

1.

  Check main and branch circuit fuses or circuit 

breakers.

2.

  Check line wire connections to fan and switch wire 

connections in the switch housings.

 

CAUTION: Make sure main power is turned off !

3.

  Make sure reversing switch position is all the way to 

one side.

4.

  Replace with fresh battery.

2.  FAN  SOUNDS  NOISY

1.

  Blades not attached to fan.

2.

  Loose screws in motor housing.

3.

  Screws securing fan blade holders to motor flywheel 

are loose.

4.

  Wire connectors inside housing rattling.

5.

  Motor noise caused by solid state variable speed 

control.

6.

  Screws holding blades to blade holders are loose.

7.

  Lower housing support set screw loose.

1.

  Attach blades to fan before operating.

2.

  Check to make sure all screws in motor housing are 

snug (not over-tight).

3.

  Check to make sure the screws which attach the fan 

blade holders to the motor flywheel are tight.

4.

  Check to make sure wire connectors in switch 

housing are not rattling against each other or against 

the interior wall of the switch housing.

CAUTION: Make sure main power is turned off !

5.

  Some fan motors are sensitive to signals from 

solid-state variable speed controls.  Solid-state controls 

are not recommended, choose an alternative control 

method.

6.

  Tighten screws securely.

7.

  Tighten set screw securely.

3.  FAN  WOBBLES

     EXCESSIVELY

1.

  Setscrew in downrod support is loose.

2.

  Setscrew in downrod/hanger ball assembly is loose.

3.

  Screws securing fan blade holders to motor hub are 

loose.  

4.

  Blade holders not seated properly. 

5.

  Hanger bracket and/or ceiling outlet box is not  

securely fastened.

6.

  Fan blades out of balance. 

1.

  Tighten both setscrews securely in downrod support. 

2.

  Tighten the setscrew in the downrod/hanger ball 

assembly. 

3.

  Check to be sure screws which attach the fan blade 

holders to the flywheel are tight. 

4.

  Check to be sure the fan blade holders seat firmly 

and uniformly to the surface of the motor housing. If 

holders are seated incorrectly, loosen the screws and 

retighten. 

5.

  Tighten the hanger bracket screws to the outlet box, 

and secure outlet box. 

6.

  Balance blades using balance kit provided in 

hardware bag.

4.  NOT  ENOUGH  AIR

     MOVEMENT

1.

  If possible, consider using a longer downrod.  For 

example, use a 12” downrod instead of the 6” downrod 

that comes with your fan.

Summary of Contents for Draco FP3220 Series

Page 1: ...3220 The Draco Ceiling Fan DRACO Fan Chrome Finish shown with Plastic Blade Set DRACO Fan Glossy Black Finish shown with Plastic Blade Set Net Weight 19 96 kg 44 lbs OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ... Some states do not allow limitations on implied warranties Fanimation will not be liable for incidental consequential or special damages arising out of or in conjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A certain amount of wobble is normal and ...

Page 3: ...s Blade Medallions Downlight Socket Plate Assembly Lower Glass Housing Cover Hardware Bags Fan Motor Housing Assembly Downrod Hanger Ball Assembly Hanger Bracket One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy Adapter Plate Plastic Blades Receiver Unit Hardware bag Seven 20 x 14mm blade holder to fan motor hub screw...

Page 4: ... Ball Retain the Pin and Hanger Ball for reinstallation in Step 6 3 The fan comes with blue black and white 80 wires Separate and untwist the three wires Route the wires and support cable through the Downrod WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Tur...

Page 5: ... groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the pin Securely tighten the setscrew in the Hanger Ball A loose setscrew could create fan wobble 7 While pulling up on the hanger ball securely tighten the two 3 16 24 x 13mm setscrews in the downrod support Figure 3 NOTE The setscrews must be properly installed as described above or fan wobble could result 9 Slide the Mo...

Page 6: ... Figure 3 Downrod Hanger Ball Assembly Attach Safety Cable to Ceiling Support Cable Tab NOTE Supply wires and fan wires omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the building structure Figure 2 You will first drill a pilot ...

Page 7: ...N LIGHT to BLUE light wire Position all connected wires and receiver antenna to allow installation of ceiling canopy To install ceiling canopy see page 8 3 After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box NOTE If fan or s...

Page 8: ...t serve as guides for easier installation 2 Securely attach the Canopy Housing to the Hanger Bracket using the external lockwashers and knurled knobs supplied with your fan Figure 1b Figure 1a Figure 1b NOTE Supply wires and fan wires omitted for clarity NOTE This step is applicable after the neccessary wiring is completed see page 7 Screw 2 per blade holder Figure 1 Blade Holder WARNING To avoid ...

Page 9: ...ower Housing Assembly 1 Loosen three screws and remove one screw from support flange Figure 1 Figure 2 Figure 3 2 Securely attach theAdapter Plate to the Support bracket and tightening three screws Figure 2 CAUTION To avoid possible electrical shock be sure electricity is turned off before installing downlight assembly ...

Page 10: ...e 5 6 Securely attach Lower Glass by tightening hex nut and Finial Nut supplied with the fan Don t overtighten Figure 6 7 You have now completed the assembly of your ceiling fan Restore electrical power INSTALLATION NOTE Be sure to line up the curved slotted holes located on both Lower Housing Support Plates Figures 4 5 Purpose of these holes are for the convience of removing and re installing the...

Page 11: ...rasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the Plastic blades is recommended A feather duster will work best Avoid using water cleansers or harsh rags which can warp and ruin the finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shoc...

Page 12: ... Support Cable Bag Containing HDWFP3220 Ceiling Support Cable Cable Clamp Flat Washer Lag Bolt 3 8 x 2 Hardware Bag Containing 5 32 Threaded Rods 2 5 32 External Lockwasher 2 Knurled Knobs 2 Screw with spring washer 5 32 32 x 8 mm 4 Hex Nut Finial Nut Wire Connectors 4 Blade Holder Mounting Hardware Bag Containing 20 x 14 mm Phillips Screws 7 Blade Mounting Hardware Bag Containing Wood Phillips Wa...

Page 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary The Draco FP3220 Exploded View 4 1 Figure 1 3 2a 8 12 ref 7 6 5 14 10 11 2b 2c 2d 2 13 12 Reversing Switch 9 ...

Page 14: ...the motor flywheel are tight 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securel...

Page 15: ......

Page 16: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 04 ...

Reviews: