- 6 -

installation 4-wire

rated voltage 

3×230/400 V

minimum measured current 

0.04 A

base current 

3×10 A

maximum current 

3×100 A

voltage measuring range 

160÷265 V

measurement accuracy (EN50470-1/3) 

B class

rated frequency 

50 Hz

insulation protection class 

II

housing 

PC+ABS material

own power consumption 

<10 VA; <0.2 W

indication range 

0÷999999.9 kWh

constant 

1000 pulses/kWh

current consumption signalling A, B, C phases 

3× red LED

read-out signalling 

red LED

pulse output

type 

open collector

maximum voltage 

27 V DC

maximum current 

27 mA

pulse time 

35÷80 ms*

working temperature 

-20÷55°C

terminal 

25 mm² screw terminals

dimensions 

7 modules (122 mm)

mounting 

on TH-35 rail

ingress protection 

IP20

__________

* depends on the current consumption 

Technical data 

Summary of Contents for LE-03d

Page 1: ...into energy absorbed througho ut the three phase system Its value is displayed by the segment LCD display The fractional digit represent the decimal 1 kWh 100 Wh Compliance Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste Accord...

Page 2: ...o connect a pulse meter reading pulses generated by the counter For proper operation of the indicator is not required to connect additional devices The meter has sealable input and output terminal covers to pre vent any attempts to bypass the meter Measured value Pulse output Sealing ...

Page 3: ... 3 The meter is marked with individual serial number allowing its unambiguous identification The marking is laser engraved and cannot be removed Meter number Front description ...

Page 4: ...terminals 1 L1 3 L2 5 L3 4 Connect the measured circuit or a single receiver to the termi nals in accordance with the markings to the terminals 2 L1 4 L2 6 L3 5 N wire connect to terminal 7 6 Additional pulse receiver connected optional to terminals 9 and 8 Additional pulse receiver is not required 7 Put the meter terminals covers Dimensions Mounting ...

Page 5: ... 5 1 power input L1IN 2 power output L1OUT 3 power input L2IN 4 power output L2OUT 5 power input L3IN 6 power output L3OUT 7 neutral N wire 8 pulse output 9 pulse output Wiring diagram ...

Page 6: ...erial own power consumption 10 VA 0 2 W indication range 0 999999 9 kWh constant 1000 pulses kWh current consumption signalling A B C phases 3 red LED read out signalling red LED pulse output type open collector maximum voltage 27 V DC maximum current 27 mA pulse time 35 80 ms working temperature 20 55 C terminal 25 mm screw terminals dimensions 7 modules 122 mm mounting on TH 35 rail ingress prot...

Page 7: ... j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE and MID Declaration of Conformity along with the refe rences to the standards in relation to which conformity is decla red can be found www fif com pl on the product subpage Warranty CE declaration ...

Page 8: ...sure that all cables are connected correctly It is essential to observe the operating conditions of the meter supply voltage humidity temperature To avoid electric shock or damage to the meter turn off the power supply whenever the connection is changed Do not make any changes to the unit yourself Doing so can result in damage to or improper operation of the device which in turn can pose a threat ...

Reviews: