- 4 -
Description of terminals
S1 input of local button controlling R1 output
S2 input of local button controlling R2 output
+ power supply: 12/24 V DC
– power supply: 0 V
R1 power output for R1 receiver
R2 power output for R2 receiver
One or more parallel connected buttons can be con-
nected to the local inputs. It is required to use mono-
stable (momentary) buttons without backlight.
Wiring diagram