1. Remove the external sensor cover - squeeze the housing from
both sides with your hand and gently pull it out of the internal
housing.
2. Disconnect the power supply.
3. Connect the wires according to the wiring diagram.
4. Fasten the base to the floor with two screws.
5. Set the sensitivity of the twilight sensor and activation time.
6. Assemble the sensor housing – press it onto internal housing.
7. Switch on the sensor power supply.
If the motion sensor is installed too close to the switched
light source, the system may be activated, which means
that the sensor will automatically switch on and off the
light source. It is necessary to move the sensor to an ap-
propriate distance away from the light source.
The sensor is inactive for the first 30 seconds after the
power supply is switched on. During this time, the PIR
system warms up.
The motion sensor can work indoors and outdoors in
places where it is not exposed to direct rain or snowfall
and to the possibility of splashing the sensor housing
and its electrical connection points with water or other
liquid.