- 3 -
1 control input
3 N power supply
4 L power supply
5 output – R1 section
6 output – R2 section
BIS-409 is compatible with backlit buttons.
The maximum total backlight current of all connected
buttons must not exceed 5 mA.
Wiring diagram
Page 1: ...er state after subsequent pulse from control button R1 and R2 contact activation is indicated by the relevant R1 and R2 red LED After a power failure state of the contact is reset When the power is ba...
Page 2: ...pply 2 Mount relay in the flush mounted box 3 Connect the power supply cables to PWR group phase L wire 4 to terminal 4 and neutral N wire to terminal 2 or 3 5 Momentary switches connected in parallel...
Page 3: ...ut 3 N power supply 4 L power supply 5 output R1 section 6 output R2 section BIS 409 is compatible with backlit buttons The maximum total backlight current of all connected buttons must not exceed 5 m...
Page 4: ...temperature 25 50 C dimensions 54 size 48 43 mm h 20 mm mounting in flush mounted box 60 ingress protection IP20 tungsten halogen fluorescent energy saving LED 1000W 600W 500W 250W 120W The above data...
Page 5: ...j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaratio...
Page 6: ......