- 4 -
1. Turn off the power.
2. Place the relay in the flush-mounted box.
3. Connect according to the scheme.
4. Set the operating time and switch-on delay using the standard
screwdriver.
input
power supply
9÷30 V DC
control inputs
potential-free
(IN, CEN, OUT)
triggered by connection
to the „–” power level
power consumption
standby
0.3 W
on
0.5 W
output
type transistor
(OC – open collector)
output current
<4 A
output voltage
9÷30 V DC
switching time Ton (adjustable)
3÷30 s
activation delay TΔ (adjustable)
0÷100% Ton
terminal
2.5 mm² screw terminals
tightening torque
0.4 Nm
working temperature
-15÷50°C
dimensions
Ø54 (48×43mm), h= 20 mm
mounting
in flush mounted box ø60
ingress protection
IP20
Mounting
Technical data
Summary of Contents for AS-225
Page 5: ...5 Example of group control...