LM.60i
7. Display
A5911664 - GB 100503
14
7.
Display
The display indicates a possible status of the program (depending on the
position of the manual operation on the LM.60i).
After the LM.60i has been switched on, 3 characters will be displayed in
succession. These characters are the version number of the software (1
character per second).
7.1.1. In manual mode (at adjustment):
Display
indication
Meaning
1.
Adjusting CLOSE (minimum air inlet position).
2.
Adjusting OPEN (maximum air inlet position).
3.
Adjusting pre-defined air inlet position
F.
Adjusting: Too small difference on the control input between
Close and Open adjustment.
E
Error when determining a position within the control procedure.
(Error)
C.
Controlling maximum air inlet position successful. (Close)
O.
Controlling minimum air inlet position successful. (Open)
P.
Controlling pre-defined air inlet position successful.
Indication of the potentiometer value. Too high, correct or too
low
7.1.2. In Automatic mode:
Display
indication
Meaning
0.
Standstill position, waiting for a change in the control value or
feedback.
1.
Actuator controls closed
2.
Actuator controls open
3.
Wait position after switch on (with control via 0-10V)
4.
Wait position after switch on (with control via IO-net; duration is
address dependent)
5.
Minimum wait position after a control action
Summary of Contents for LM.60i
Page 1: ...LM 60i Manual GB...
Page 34: ...LM 60i Appendix 3 A5911664 GB 100503 30 Appendix 3 Mountings...
Page 35: ...LM 60i Appendix 3 A5911664 GB 100503 31 1 Mounting cable reel...
Page 37: ...LM 60i Appendix 3 A5911664 GB 100503 33 3 Mounting CE protection cover on cable reel...
Page 38: ...LM 60i Appendix 3 A5911664 GB 100503 34 4 Mounting pipe chain coupling 1...