Lumina 750
Using the Lumina 750
à
Dial
Readout of the measured fan capacity (%) or the total air flow (m
3
/hour) in the
growing room.
Readout of the circulation control value currently used by the control computer to
regulate fan speed. This value can be a percentage of the fan capacity (%) or the
total air flow (m
3
/hour).
Setting of the minimum fan capacity (%) or the minimum air flow (% or m
3
/hour).
The
Fan capacity control value
may never drop below the
Minimum fan capacity
set
value, except when there is a frost alarm or fan failure.
Setting of the maximum fan capacity (%) or the maximum air flow (% or m
3
/hour).
The
Fan capacity control value
may never rise above the
Maximum fan capacity
set
value.
Setting of how much the fan speed should increase every day (% or m
3
/h).
3.1.7
Compost temperature control
Classic compost temperature control settings: see.