background image

31 Dunlop Road Mulgrave Victoria 3170
Ph 03 9538 9200 Fax 03 9538 9299
[email protected]
www.masterdistributors.com.au

INSTALLATION AND MOUNTING 
INFORMATION

WARNING: 

Smoke alarm installation must be in 

accordance with the requirements of the national 
electrical code and any local codes that may apply 
and by a competent person.

1. From back of the smoke alarm, remove the 
mounting plate by turning it counterclockwise. (To 
later engage tamper-resist feature, twist out and 
set aside one of the pins moulded into plate. Both 
pins are exactly the same).

30092014

2. Secure plate to ceiling or wall with mounting 
screws appropriate to the surface on which the 
unit is to be mounted.

3. Lift open battery pocket door.

4. Connect new 9 volt battery to battery connector 
inside battery pocket. Be sure battery is securely 
connected. The red LED may blink briefly when 
battery is installed.

5. Close battery pocket door, snapping it into 
place.

6. Position smoke alarm to mounting plate and 
turn clockwise to lock into place. To engage 
tamper-resist feature, insert pin into notch and 
edge of smoke alarm after alarm is properly 
positioned in base.

7. Push test button to test smoke alarm. See 
OPERATION, TESTING AND MAINTENANCE.

OPERATION, TESTING AND MAINTENANCE
Operation 

Normal Operation

 When no smoke is present, a 

red LED indicator will flash ONCE A MINUTE and 
is an indication that the unit is operating properly. 

The hush feature can mute the detector if it has 
been inadvertently triggered by holding down the 
test/hush button for a few seconds. The smoke 
alarm will be muted for 10 minutes and then reset 
into normal mode after this period.

NOTE:

 If the smoke density increases during the 

hush period the smoke alarm will be triggered into 
sounding again.

Alarm Condition 

When the unit detects smoke, the red LED 
indicator will flash rapidly and alarm will sound 
loudly until the air is clear.

Testing the Smoke Alarm 

Test the smoke alarm once a week. If the smoke 
alarm ever fails to test correctly, have it replaced 
immediately! If the smoke alarm is not working 
properly, it cannot alert you to a problem.

1. Test each smoke alarm to be sure it is installed 
correctly and operating properly.

2. The push-to-test button accurately tests 
functions. DO NOT use an open flame to test this 
smoke alarm. You may ignite and damage the 
smoke alarm or your home.

3.  Stand at arm’s length from the smoke alarm 

Mounting Slots
Mounting

Bracket

Screw

9V Battery

when testing.

4. To test the smoke alarm firmly press the test 
button, and the alarm will sound a loud beep. The 
alarm will stop sounding after releasing the test 
button. If the alarm does not sound please re-test 
the alarm.

WARNING: 

If the alarm sounds and the smoke 

alarm is not being tested, the smoke alarm is 
sensing smoke. The sound of the alarm requires 
your immediate attention and action.

WARNING:

 DO NOT disconnect battery to silence 

an unwanted alarm. This will remove your 
protection. Ventilate the unit or open a window to 
remove smoke or dust.

Maintenance 

The smoke alarm is virtually maintenance free. 
However, under dusty conditions, a vacuum hose 
may be used to clear dust through the side 
opening. It is recommended to clean the alarm 
monthly to keep best performance. Normally, the 
alarm can be operated up to 10 years without 
replacement. See the replacing date on the bottom 
of the alarm unit. DO NOT attempt to remove the 
cover to clean inside the smoke alarm. This will 
void your warranty.

HUSH FEATURE 

This smoke alarm is equipped with a combined 
test & hush button to help control nuisance alarms. 
If there is a nuisance alarm simply press the 
test/hush button to silence the unit for 10 minutes. 
The unit will flash a red LED every 10 seconds 
(instead of the normal 40 seconds) to indicate the 
sensitivity has been reduced. The unit will reset to 
normal sensitivity at the end of the hush period. If 
additional hush time is required, simply push the 
test/hush button again.

NOTE:

 If a nuisance alarm occurs and if there is no 

sign of smoke, heat or noise to suggest a fire you 
should get your family to a safe place before 
investigating. Check the household carefully in 
case there is a small fire smouldering out of sight, 
or if there is another source of smoke or fumes 
such as cooking fumes being drawn past a smoke 
alarm by an extractor. 

WARNING:

 If there are frequent nuisance alarms it 

may be necessary to re-locate the device away 
from the source of the fumes. If the alarm continues 
sounding nuisance alarms without smoke or heat 
being present it may require some maintenance or 
cleaning.

BATTERY REPLACEMENT 

The power of this smoke alarm is provided by one 
9V DC battery. The battery should last for at least 
1 year under normal operating conditions. The 
smoke alarm has a low battery indicator, an 
audible ‘chirp’. It will operate at 30-40 second 
intervals for a minimum of 7 days. Replace the 
battery when this indication occurs. Only the 
following 9V DC batteries (which are available at 
hardware or electronic parts stores) may be used 
for replacement.

Carbon-Zinc Type: Eveready #216; Gold Peak 
#1604P; Gold Peak #1604S; Gold Peak 1604G; 
Premisafe G6F22.

Alkaline Type: Eveready Energizer #522; Gold 
Peak #1604A; Duracell #MN1604; Hi-Watt 
#6LR61X.

Lithium Type: Ultralife U9VL-J; FDK CP-V9J; Gold 
Peak CR-V9.

CAUTION:

 Switch off smoke alarm before 

removing smoke alarm for battery replacement.

WARNING:

 DO NOT use any other type of battery, 

other than as specified in this manual. DO NOT use 
rechargeable batteries.

CAUTION:

 If the battery is incorrectly replaced, the 

smoke alarm will not operate and may cause 
damage.

WHAT TO DO IN CASE OF A FIRE

• If there is a fire in your home, the precautions 

described will increase your chance of escaping 
safely. The following rules should always be 
highlighted during fire drills so that they are 
remembered in the case of a real emergency. 

• Stay calm and think clearly about the 
pre-arranged escape plan.

 

• Leaving the house as soon as possible following 
the planned escape route. Do not stop to collect 
personal belongings.

• Check doors to see if they are hot. If the door is 
hot, do not open it - use another escape route.

• Keep all doors and windows shut, only open as a 
means of escaping.

• Smoke rises, so keep close to the floor - if 
necessary crawl.

• Take short breaths and if possible, cover your 
mouth and nose with a wet cloth.

• Make your way to the pre-arranged meeting point 
and call the fire brigade. Give your full name and 
address.

• Never re-enter a burning house. For further 
information on fire safety and prevention, contact 
your local fire prevention officer.

WARNING:

 Do not try to disassemble this smoke 

alarm, as it may damage or impede the operation. 
No user serviceable parts inside. The warranty will 
become void if misuse or abuse is apparent. This 
10 year warranty is also conditional on this unit 
being installed by a licensed electrical contractor in 
accordance with local building codes.

1

0 YEAR WARRANTY 

The smoke alarm is warranted to be free from 
defects in materials and workmanship for ten (10) 
years from the date of purchase and is not 
transferable under normal use. The warranty does 
not cover natural disasters such as fire, flood, 
hurricanes and tornados. Warranty is conditional 
on the smoke alarm being used in the normal way 
and not being modified or subject to attempted 
repairs or contamination. The warranty excludes 
the battery, incidental and consequential damages. 
Your statutory rights as a consumer are in no way 
compromised by this warranty. Master Distributors 
Pty Ltd agrees to repair or replace, at its option, any 
defective smoke alarm provided it is returned 
personally or by prepaid delivery with a copy of 
proof of purchase. This warranty does not cover 
damages resulting from lack of reasonable care of 
the product. 

Our goods come with guarantees that cannot be 
excluded under the Australian Consumer Law. You 
are entitled to a replacement or refund for a major 
failure and for compensation for any other 
reasonably foreseeable loss or damage. You are 
also entitled to have the goods repaired or replaced 
if the goods fail to be of acceptable quality and the 
failure does not amount to a major failure. 

Subject to those non-excluded rights and 
provisions and the above warranty, Master 
Distributors Pty Ltd will not be liable for injury to 
persons, damage to property, or for any direct or 
indirect or consequential damage as a result of 
negligence or fault on the part of Master 
Distributors Pty Ltd or it’s servants, agents, 
suppliers and contractors or otherwise arising out 
of or resulting from, whether directly or indirectly, 
the use, installation or maintenance of the heat 
alarm and any warranties or representations are 
excluded unless given by Master Distributors Pty 
Ltd in writing. Please leave this document, or a 
copy, for the end user.

FOR MORE INFORMATION AND FAQ PLEASE 

VISIT WWW.FAMILY-FIRST.COM.AU

Reviews: