Fame Audio REC0008047-000 Manual Download Page 8

 

 
 
 

 

ENGLISH 

 

Cleaning:

 

 
Regular cleaning of the device from dirt and dust increases the shelf life of the product. Always 

disconnect the device from the power supply before cleaning it! Never clean the appliance wet! A 
dry microfibre cloth is best.  

Ventilation grilles and openings should always be cleaned of dust and dirt. Suitable compressed 
air sprays are recommended for this application. 

 
 

Envrionmental protection: 

 

The company MUSIC STORE professional GmbH always strives to reduce the burden of packaging 
to a minimum. The use of environmentally friendly and recyclable materials is of fundamental 

importance to us. Please dispose of and recycle the packaging components after use properly. 
 

 

Disposal of packaging: 

Ensure that paper packaging, plastic materials, etc. are separately recycled. Observe the 

corresponding disposal instructions on the packaging. 
 

 

Disposal of batteries: 

Batteries do not belong in the garbage! Please keep batteries in accordance with the 
official collection points or disposal stations in accordance with the specifications. 

 
 

Disposal of your old device: 

Do not dispose of the device with household waste! This device is subject to the WEEE 

Directive (Waste Electrical and Electronic Equipment) in its currently valid version. 
 

The device will be disposed of by an approved waste disposal company or your local waste 

disposal office. The regulations valid in your country must be observed! 
 

 
 

 
 

Manufacturer: MUSIC STORE professional GmbH,  
Istanbulstraße 22-26,  
51103 Cologne, Germany 
 
 
 

 

Summary of Contents for REC0008047-000

Page 1: ...from the manufacturer Always make sure that the grounding of the device is maintained Only use the supplied power cables and always maintain the earthed protective contacts on the side Make sure that the sockets used have a properly functioning protective earth Failure to do so may result in fire or death due to electric shock DANGER For babies and children Dispose of or store any packaging materi...

Page 2: ...isconnect the device from the power source in order to minimize danger Never pull the cable while phantom power is active Hint Condensation To avoid condensation in the unit the unit should adapt to the ambient temperature before commissioning Hint Unwanted odours A new product can sometimes lead to unwanted odours This reaction is normal and disappears after a few minutes Hint Damage to loudspeak...

Page 3: ...ctions in the manual The lightning warns you of dangerous voltage accessible from the outside A connection to any terminal marked with this symbol may only be made with a ready made cable that complies with the manufacturer s recommendations or with cables installed by qualified personnel Only suitable for indoor use Read the manual Please read and follow the warnings and recommendations carefully...

Page 4: ...hael Sauer WEEE Reg No DE 41617453 Tel 49 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product FAME Audio Studio CO5 was designed for use as a microphone The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and can lead to damage to proper...

Page 5: ...se This large diaphragm condenser microphone has a three pin XLR connector and comes with a matching bracket Due to its characteristics the FAME Audio Studio C05 is used for miking vocals speech guitar and percussion Commissioning All connections of the device should be made before switching on Only use high quality undamaged and as short cables as possible for the connections Configuration of the...

Page 6: ...stics are mixed Example application 1 Omnidirectional Since the omnidirectional characteristic has no extinctions due to the design of the microphone sound from all directions can be picked up almost uniformly Example application 2 Cardioid Sound hitting the rear is extinguished dampened by the cardioid characteristic The focus here is on the direct signal FAME Audio Studio CO5 Cardioid characteri...

Page 7: ...uivalent noise level 22 dB A weighted Sound pressure level limit for K 0 5 125 dB Signal to noise ratio 79 dB Power supply Phantom power 48 V Connection XLR 3 pin Symptom Troubleshooting No tone Check the cable for damage cuts extreme kinks etc and replace if necessary Check the wiring Connectors must be fully inserted and snap into place Check if the 48V phantom power is switched on at the consol...

Page 8: ...the packaging components after use properly Disposal of packaging Ensure that paper packaging plastic materials etc are separately recycled Observe the corresponding disposal instructions on the packaging Disposal of batteries Batteries do not belong in the garbage Please keep batteries in accordance with the official collection points or disposal stations in accordance with the specifications Dis...

Page 9: ...ENGLISH MS ID REC0008047 000 02 2019 Notes ...

Reviews: