ENGLISH
Specifications:
Troubleshooting:
The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the
manufacturer, the dealer or the corresponding specialist personnel.
If the specified corrections have not led to success, please contact our service staff. The contact
details can be found at www.musicstore.de
Model
Studio CO5
Sound conversion principle
FET Condenser Microphone
Membrane size
1 inch large diaphragm, gold plated
Directional characteristic
Cardioid
Frequency range
20 Hz – 20 kHz
Field transmission factor
12 mV/Pa (at 1 kHz)
Output impedance
250 Ohm
Equivalent noise level
22 dB (A-weighted)
Sound pressure level limit for K <
0.5%
125 dB
Signal-to-noise ratio
79 dB
Power supply
Phantom power +48 V
Connection
XLR 3 pin
Symptom
Troubleshooting
No tone
Check the cable for damage (cuts, extreme kinks,
etc.) and replace if necessary.
Check the wiring. Connectors must be fully
inserted and snap into place!
Check if the 48V phantom power is switched on at
the console/interface.
Check the setting of the preamplifier on the
console/interface/etc.
Delayed tone
Change the buffer size in the DAW settings. The
lower the number, the lower the latency. (Note:
with a low buffer size, the machine requires higher
performance. Depending on the computer, this
can lead to higher performance losses).
For more