Remove the lange from the hood (1).

Fixing the brackets onto the rectangular 

connection (2).

INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR

Summary of Contents for Nuvola Series

Page 1: ...INSTALLATION MANUAL falmecau com Nuvola...

Page 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Page 3: ...2 HOLE SIZES 940 1325 505 590 540 625 973 1358 925 1310 492 577 370 556 128 min 10 max 25 341 239 275 95 275 150 NUVOLA 90 32 KG NUVOLA 140 45 KG INSTALLATION WITH MOTOR ON THE HOOD...

Page 4: ...3 HOLE SIZES 940 1325 505 590 540 625 973 1358 216 472 min 10 max 25 128 925 1310 492 577 370 246 193 144 86 95 556 640 NUVOLA 90 31 KG NUVOLA 140 44 KG INSTALLATION WITH SLIM MOTOR...

Page 5: ...4 HOLE SIZES 940 1325 505 590 540 625 973 1358 925 1310 492 577 370 556 128 min 10 max 25 275 275 86 216 193 95 144 NUVOLA 90 24 KG NUVOLA 140 37 KG INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 6: ...5 HOLE SIZES 940 1325 505 590 min 10 max 25 128 540 625 973 1358 95 925 1310 492 577 150 130 NUVOLA 90 22 KG NUVOLA 140 35 KG INSTALLATION WITH REMOTE MOTOR...

Page 7: ...6 Max 1500 mm 9 mm MEASUREMENTS FOR INSTALLATION...

Page 8: ...C O N T R O S O F F I T T O 2 m i n 6 0 m m min 60 mm 1 F A L S E C E I L I N G C O N T R O S O F F I T T O G 3 4 double adhesive 2 1 H H x 1 2 Cutting the plasterboard 1 inserting the supporting fram...

Page 9: ...8 X Y X 1 2 Y 4 3 9 mm 3 Fixing the mandatory safety chains to the ceiling PRELIMINARY OPERATIONS...

Page 10: ...9 Open the panel remove the filters 4 and gas piston 5 1 4 2 3 2 1 4 5 PRELIMINARY OPERATIONS...

Page 11: ...10 INLET 1 2 3 Remove the flange from the hood 1 and the motor 2 If the air outlet is upward see 3 For other directions see 4 and 5 INSTALLATION WITH MOTOR ON THE HOOD...

Page 12: ...11 5 4 AIR 180 3 4 90 5 x 8 6 x 8 2 1 OUTLET INSTALLATION WITH MOTOR ON THE HOOD Side movement of the air exhaust...

Page 13: ...12 120 mm x8 x4 1 3 1 2 3 6 INSTALLATION WITH MOTOR ON THE HOOD...

Page 14: ...13 7 1 2 8 INSTALLATION WITH MOTOR ON THE HOOD Fixing the motor support brackets 7 Positioning the motor on the support frame 8...

Page 15: ...14 15 950 m3 h 1100 m3 h 150mm 1 2 3 9 INSTALLATION WITH MOTOR ON THE HOOD Fitting the suction pipe and electrical connection 9...

Page 16: ...15 2 1 1 2 Remove the flange from the hood 1 Detach pre cut elements and position the slim motor bracket SLIM MOTOR...

Page 17: ...16 A I R 145 5 S L I M L M 2 1 3 V 1 x8 4 V2 x4 3 Fixing the motor support brackets 3 SLIM MOTOR INSTALLATION...

Page 18: ...17 1 2 L M H G SLIM 217mm 87mm 800 m3 h 1 2 3 4 5 Positioning the motor on the support frame 4 Fitting the suction pipe and electrical connection 5 SLIM MOTOR INSTALLATION...

Page 19: ...18 120 mm AIR AIR 3 4 2 2 V2 x4 V1 x 8 120 mm 3 V1 x8 4 V2 x4 2 1 Remove the lange from the hood 1 Fixing the brackets onto the rectangular connection 2 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 20: ...19 1 2 L CT M H G 3 1 217mm 87mm CUE 2 4 Positioning the rectangular connection on the support frame 3 Fitting the suction pipe 4 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 21: ...20 1 2 150mm 200 mm KAC L 396 N O V A L V E O P T I O N A L 1 2 Fitting the non return valve 1 REMOTE MOTOR INSTALLATION...

Page 22: ...21 F 1 2 REMOTE MOTOR REMOTE EXTERNAL MOTOR 3 Fixing the suction pipe 3 REMOTE MOTOR INSTALLATION...

Page 23: ...22 x2 2 1 CM 1 Passing the chains through passing the control cable through FINAL OPERATIONS...

Page 24: ...23 V3 OK Disassembly 2 1 2 Closing the holding brackets FINAL OPERATIONS...

Page 25: ...24 CM CE 1 V4 2 V 5 x 4 V 6 x 4 V 5 x 8 V 5 x 8 4 3 Fixing the motor or rectangular connection 3 electrical connection and tensioning the safety chains 4 FINAL OPERATIONS...

Page 26: ...25 3 1 2 5 Repositioning of the front glass filters and side glass panels FINAL OPERATIONS...

Page 27: ...he safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to...

Page 28: ...sed at the same time as appliances that are powered by energy other than electricity the negative pressure in the room must not exceed 4 Pa 4 x 10 5 bar HOOD WITH INTERNAL RECIRCULATION FILTERING In t...

Page 29: ...parts or parts related to the motor inside the hood with liquids or solvents For the internal metal parts see the previous paragraph METAL ANTI GREASE FILTERS It is advised to frequently wash the meta...

Page 30: ...ct by building materials of any kind will be required to be removed and reinstalled by the customer 10 PR Kitchens Washrooms has a service network in all metropolitan areas and most regional areas Whe...

Page 31: ...31 NOTE NOTES...

Page 32: ...o Treviso Italy falmec com Australia PR Kitchen Washroom Systems 83 Bangholme Rd Dandenong South VIC 3175 Australia 61 3 9700 9100 info prks com au New Zealand PR Kitchen Washroom Systems NZ P O Box 5...

Reviews: