  WARRANTY

All FALMEC rangehoods come with a 5 year parts and labour warranty. PR Kitchens & 
Washrooms will correct, free of charge, any defects in material or workmanship for the 
period of 5 years, subject to the terms of our warranty stated below.

This  warranty  will  be  void  if  a  Falmec  range  hood  is  used  for  commercial  purposes. 
Some examples of commercial purposes but not limited to, include restaurants, cafes, 
schools and clubs.

Rangehoods  in  the  Falmec  range  (excluding  BBQ  models)  are  designed  and 
warranted “strictly” for indoor use only (household kitchen).

1. This warranty only applies for products installed by a qualified person and when 
provided with a certificate of compliance in accordance with State/Territory laws.

2. This product must be used in accordance with the manufacturer’s instructions. This 
warranty does not apply should the defect in or failure of the product be attributable to 
misuse, abuse, accident or non-observation of the manufacturer’s instructions on the 
part of the user. FALMEC appliances does not accept liability for any direct or 
consequential loss, damage or other expense caused by or arising out of any failure to 
install or use the product in accordance with the manufacturer’s instructions.

3. The warranty does not cover failures due to normal wear and tear with reasonable 
use or consumable components such as globes, filters, etc.

4. PR Kitchens & Washrooms, at its own discretion may replace or repair any defective 
component(s) to affect a repair due to any faulty workmanship and material. The 
warranty does not cover breakage of outer glass panels attributed to external damage.

5. The warranty provided is a “Repair Warranty” and in an extreme event if a repair 
cannot take place, a replacement will be provided of an equivalent current model where 
the balance of the warranty period from the original date of purchase will take effect.

6.  This  warranty  is  immediately  void  if  the  serial  or  model  number  label  is  removed, 
defaced,  serviced  or  repaired  by  a  unauthorised/unqualified  personal  or  used  for 
industrial/commercial purposes.

7. Warranty will be only provided when a proof of the original purchase is presented to 
an authorised dealer or reseller before or at the time of service.

8. This warranty does not cover any corrosion or defect as a result of the product being 
installed in an environment in which the appliance is not protected from the weather.

9. It is the responsibility of the customer to ensure the appliance is easily accessible for 
a service technician to carry out required repairs. Any obstruction prohibiting access to 
the product by building materials of any kind will be required to be removed and 
reinstalled by the customer.

10. PR Kitchens & Washrooms has a service network in all metropolitan areas and most 
regional areas. Where the warranty claim has been made outside a radius of 50km from 
any store where the product can be purchased, the customer is responsible for the cost 
of delivery to the nearest service agent or the travel cost for a technician to travel to a 
location outside the 50km radius.

PRODUCT SOLD IN AUSTRALIA ONLY

:

At PR Kitchens & Washrooms our goods come with guarantees that cannot be 
excluded under the Australian Consumer Law. You are entitled to a replacement or 
refund for a major failure and compensation for any other reasonably foreseeable loss 
or damage. You are also entitled to have the goods repaired or replaced if the goods 
fail to be of acceptable quality and the failure does not amount to a major failure.

OUTDOOR USE RANGEHOODS

Outdoor  BBQ  models  from  Falmec  are  warranted  for  use  above  barbecues  and  in 
alfresco areas with one open wall and a solid roof such as that they are not exposed to 
the elements.

Outdoor  BBQ  models  MUST  only  have  the  specified  2010  m3/hr  motor  installed  in 
conjunction with the hood.

In  the  scenario  where  the  hood  is  located  near  the  ocean  or  exposed  to  salty  air, 
regular care and cleaning of the hood is recommended to prevent any corrosion.

REMOTE MOTOR RANGE HOODS

In addition to the standard 5 years parts and labour warranty stated above the remote 
motors from the Professional series are covered for an additional 5 years as a part only 
warranty therefore giving a total coverage of 10 years. This warranty is conditional by 
the following items

If installed in coastal applications the external housing must have anti-corrosive 

coating applied. The internal fan may also require additional cleaning/washdown as a 
result of exposure to salt in the air.

Fan must be installed in a position that it will not be subjected to excessive duct 

temperatures (40˚ covers all models).

Filters must be in place within the rangehood and regularly maintained/cleaned/

replaced as needed.

SUPPORT

At PRKS we place great importance on customer satisfaction and that is why we have 
established a dedicated and experienced customer support team that you can rely on.

Should  you  ever  need  to  make  a  warranty  related  enquiry  about  your  FALMEC 
product, you can lodge the enquiry at:

AUSTRALIA

www.prkws.com 

[email protected] 

03 9700 9100

NEW ZEALAND

www.prkws.com 

[email protected]

 09 964 0400

We suggest you have the following information close at hand:

1. Model number of your product

2. A copy of your original purchase receipt

3. Address details of where the product is installed.

Any relevant pictures can be attached if lodging the claim online 

Summary of Contents for nube

Page 1: ...INSTALLATION MANUAL falmecau com Nube...

Page 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Page 3: ...2 HOLE SIZES 540 973 925 492 370 556 128 min 10 max 25 341 239 275 95 275 150 940 505 NUBE 32 KG INSTALLATION WITH MOTOR ON THE HOOD...

Page 4: ...3 HOLE SIZES 940 505 128 472 216 min 10 max 25 246 193 144 370 925 492 973 540 95 86 556 NUBE 31 KG INSTALLATION WITH SLIM MOTOR...

Page 5: ...4 HOLE SIZES 940 505 540 973 925 492 370 556 128 min 10 max 25 275 275 86 216 193 95 144 NUBE 24 KG INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 6: ...5 HOLE SIZES 940 505 973 492 925 128 540 min 10 max 25 95 150 130 NUBE 22 KG INSTALLATION WITH REMOTE MOTOR...

Page 7: ...6 Max 1500 mm 9 mm MEASUREMENTS FOR INSTALLATION...

Page 8: ...C O N T R O S O F F I T T O 2 m i n 6 0 m m min 60 mm 1 F A L S E C E I L I N G C O N T R O S O F F I T T O G 3 4 double adhesive 2 1 H H x 1 2 Cutting the plasterboard 1 inserting the supporting fram...

Page 9: ...8 X Y X 1 2 Y 4 3 9 mm 3 Fixing the mandatory safety chains to the ceiling PRELIMINARY OPERATIONS...

Page 10: ...9 1 4 2 3 2 1 4 5 PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS Open the panel 4 and remove the filters 5...

Page 11: ...10 INLET 1 2 3 Remove the flange from the hood 1 and the motor 2 If the air outlet is upward see 3 For other directions see 4 and 5 MOTOR ON HOOD INSTALLATION...

Page 12: ...11 5 4 AIR 180 3 4 90 5 x 8 6 x 8 2 1 OUTLET Side movement of the air exhaust MOTOR ON HOOD INSTALLATION...

Page 13: ...12 120 mm x8 x4 1 3 1 2 3 6 Fixing the motor support brackets 6 MOTOR ON HOOD INSTALLATION...

Page 14: ...13 7 1 2 8 MOTOR ON HOOD INSTALLATION Fitting the non return valve 7 Positioning the motor on the support frame 8...

Page 15: ...14 15 950 m3 h 1100 m3 h 150mm 1 2 3 9 Fitting the suction pipe and electrical connection 9 MOTOR ON HOOD INSTALLATION...

Page 16: ...15 2 1 1 2 Remove the flange from the hood 1 detach the pre cut elements and position the SLIM motor bracket 2 SLIM MOTOR INSTALLATION...

Page 17: ...16 A I R 145 5 S L I M L M 2 1 3 V 1 x8 4 V2 x4 3 Fixing the motor support brackets 3 SLIM MOTOR INSTALLATION...

Page 18: ...17 1 2 L M H G SLIM 217mm 87mm 800 m3 h 1 2 3 4 5 Positioning the motor on the support frame 4 Fitting the suction pipe and electrical connection 5 SLIM MOTOR INSTALLATION...

Page 19: ...18 120 mm AIR AIR 3 4 2 2 V2 x4 V1 x8 120 mm 3 V1 x8 4 V2 x4 2 1 Remove the flange from the hood 1 Fixing the brackets onto the rectangular connection 2 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 20: ...19 1 2 L CT M H G 3 1 217mm 87mm CUE 2 4 Positioning the rectangular connection on the support frame 3 Fitting the suction pipe 4 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Page 21: ...20 1 2 150m m 200 mm KACL 396 N O V A L V E O P T I O N A L 1 2 Fitting the non return valve 1 INSTALLATION WITH REMOTE MOTOR...

Page 22: ...21 F 1 2 REMOTE MOTOR REMOTE EXTERNAL MOTOR 3 Fixing the suction pipe 3 INSTALLATION WITH REMOTE MOTOR...

Page 23: ...22 x2 2 1 CM 1 Final operations Passing the chains through passing the control cable through FINAL OPERATIONS...

Page 24: ...23 Closing the holding brackets V 3 O K Disassembly 2 1 2 FINAL OPERATIONS...

Page 25: ...24 C M C E 1 V4 2 V5 x 4 V6 x4 V5 x8 V5 x8 4 3 Fixing the motor or rectangular connection 3 electrical connection and tensioning the safety chains 4 FINAL OPERATIONS...

Page 26: ...25 3 1 2 Repositioning filters and piston and closing the hood 5 FINAL OPERATIONS...

Page 27: ...he safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to...

Page 28: ...that are powered by energy other than electricity the negative pressure in the room must not exceed 4 Pa 4 x 10 5 bar HOOD WITH INTERNAL RECIRCULATION FILTERING In this model the air passes through an...

Page 29: ...tions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liquids or solvents For the internal metal parts see the previous paragraph METAL A...