INSTALLATION MANUAL 
MILANO SERIES 
GENOVA 120

13 MAR 2018 - V 1.2

Summary of Contents for MILANO Series

Page 1: ...INSTALLATION MANUAL MILANO SERIES GENOVA 120 13 MAR 2018 V 1 2...

Page 2: ...HE RANGEHOOD PLEASE REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN...

Page 3: ...Duct Clamps x2 3 200mm Flexi Duct 5 Meters Length OPTIONAL ACCESSORIES WHEN ROOF MOUNTING 1 200 mm Tile Roof Install Kit HBX200TILE Includes roof flashing for tile roof and mounting brackets x2 2 200...

Page 4: ...cated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to another person make sur...

Page 5: ...se Turning the timer function ON or OFF In operating mode press button 1 to engage the timer function The default time set is 15 minutes and cannot be increased or decreased BUTTON 1 TIMER Red LED fla...

Page 6: ...hereceiverisactive Thisprocedureisalsousedtodeactivatethereceiver RADIO CONTROL CODE CHANGE Withonlyoneradiocontrol godirectlytopoint2 With several radio controls in the same room a new code can be cr...

Page 7: ...tforittobecompletelydrybeforereassembling it Theyaredishwashersafe 3 2 1 MAINTENANCE The crossed out trash or refuse bin symbol on the appliance means that the product is WEEE i e Waste electrical and...

Page 8: ...to enlarge the duct size to ensure optimum performance The manufacturer does not guarantee performance when the duct length is greater than five 5 metres THE RECOMMENDED DUCT LENGTH INSTALLATION DIST...

Page 9: ...the main body of the rangehood along the back above the grease trap on the left and right side Once the screws are removed the main body of the rangehood will separate away from stainless steel fascia...

Page 10: ...600 650 m m 1 2 3 4 1 2 3 4...

Page 11: ...2 2 1 2 3 1 5 7 8 6...

Page 12: ...512 822 250 560 870 505 815 379 689 280 200 117 280 331 341 247 214 CUTOUT DIMENSIONS MILANO 60 90...

Page 13: ...MILANO 90 120 DEEP 870 1160 804 1094 200 380 117 814 1104 330 CUTOUT DIMENSIONS 10 321 356 235 326 563 852 204...

Page 14: ...GENOVA 120 1160 1095 200 470 117 1110 445 CUTOUT DIMENSIONS 10 296 332 435...

Page 15: ...unit Advise to include gentle bend in duct run as well ensuring ducting is pulled tight and excess removed 1 Fan power supply attached to internal hood unit 2 200mm flexi duct installed between range...

Page 16: ...d the outside The direction of airflow is marked on the In roof motor unit STEP 3 Cut a 205 mm diameter hole in the wall or eave to enable the mounting of the external vent Please ensure that the hole...

Page 17: ...hood to the bottom of the rigid duct using the supplied duct clamps 9 Connect the male power plug to the female plug connected to the rangehood An extension lead purchased separately can be used if ne...

Page 18: ...s as required 9 Attach the flexi duct leading from the rangehood to the bottom of the rigid duct using the supplied duct clamps purchased separately can be used if necessary if the duct run has been e...

Page 19: ...flexi duct leading from the rangehood to the spigot using the supplied duct clamps 10 Fix fan to wall with appropriate fastening screws 11 Connect the male power plug to the female plug connected to t...

Page 20: ...518 147 450 419 123 360 EW 765 EW 1140 SPECIFICATIONS EW 2010 SPECIFICATIONS 130 80 162 5 325 298 6 5 4 holes 425 388 6 5 4 holes 170 80 212 5 All measurements in mm All measurements in mm...

Page 21: ...xtremeeventifarepaircannottakeplace areplacementwillbeprovidedof anequivalentcurrentmodelwherethebalanceofthewarrantyperiodfromtheoriginaldateofpurchasewilltakeeffect 6 Thiswarrantyisimmediatelyvoidif...

Page 22: ...tsonlywarrantythereforegivingatotalcoverageof10years Thiswarrantyisconditionalbythe followingitems Ifinstalledincoastalapplicationstheexternalhousingmusthaveaanti corrosivecoatingapplied Theinternalfa...

Page 23: ......