FALMEC Mercurio XL island Instruction Booklet Download Page 16

16

b) Always turn hood ON when cooking at high 

heat or when flambeing food (i.e. Crepes Suzette, 

Cherries Jubilee, Peppercorn Beef Flambe').

c) Clean ventilating fans frequently. Grease should 

not be allowed to accumulate on fan or filter.

d) Use proper pan size. Always use cookware ap-

propriate for the size of the surface element.

WARNING:TO REDUCE THE RISK OF INJURY TO 

PERSONS IN THE EVENT OF A RANGE TOP GREASE 

FIRE, OBSERVE THE FOLLOWING

a

:

a) SMOTHER FLAMES with a close-fitting lid, cook-

ie sheet, or metal tray, then turn off the burner. 

BE CAREFUL TO PREVENT BURNS. If the flames 

do not go out immediately, EVACUATE AND CALL 

THE FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN – You may be 

burned.

c) DO NOT USE WATER, including wet dishcloths 

or towels – a violent steam explosion will result.

d) Use an extinguisher ONLY if:

1) You know you have a Class ABC extinguisher, 

and you already know how to operate it.

2) The fire is small and contained in the area 

where it started.

3) The fire department is being called.

4) You can fight the fire with your back to an exit.

Based on "Kitchen Firesafety Tips" published by 

NFPA.

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching 

off the main switch.

Do not use the hood with wet hands or bare feet.

Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 

The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

3lb 5 oz (1.5 Kg).

Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.

Do not leave open, unattended flames under the 

hood.

Do not prepare food over an open flame under the 

hood.

Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.

Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.

Do not carry out any cleaning operations when parts 

of the hood are still hot.

There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.

Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room 

where the fumes are discharged is well-ven-

tilated, in compliance with the local regula-

tions.

  INSTALLATION

   only intended for qualified personnel

Before installing the hood,

carefully read the chapter

'SAFETY INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-

ment and the lowest part of the hood is indicated in the installation in-

structions. 

Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be-

fore carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions of law 

in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the techni-

cal specifications located inside the hood);

•  the power supply plug and cable do not come into contact with tempera-

tures exceeding 158°F (70 °C);

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.

In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to 
an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, or any 

other device that ensures disconnection from the electrical mains, with an 
opening gap of the contacts that enables total disconnection in overvoltage 
category III conditions.

  Said disconnection devices must be provided in the mains power supply in 

compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety 
regulations.

FUMES DISCHARGE

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside 
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a 
pipe, to an external output.
The outlet pipe must have:
• 

a diameter not less than that of the hood fitting.

• 

a slight slope downwards (drop) in the horizontal sec-

tions to prevent condensation from flowing back into the motor.

•  the minimum required number of bends.

Summary of Contents for Mercurio XL island

Page 1: ...INSTRUCTIONS BOOKLET Design INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT Mercurio Mercurio XL island FPMEX36I6SS R FPMEX42I6SS R...

Page 2: ...3 4 121 mm 35 3 8 898 mm 21 5 8 550 mm 600 cfm EN cable length 4 ft 1 2m FR longueur de c ble 4 ft 1 2m ES longueur de c ble 4 ft 1 2m IT lunghezza cavo 4 ft 1 2m 61 lb 28 kg MERCURIO ISLAND XL 36 Co...

Page 3: ...3 4 121 mm 41 3 4 1060 mm 21 5 8 550 mm EN cable length 4 ft 1 2m FR longueur de c ble 4 ft 1 2m ES longueur de c ble 4 ft 1 2m IT lunghezza cavo 4 ft 1 2m MERCURIO ISLAND XL 42 Cod FPMEX42I6SS R EN...

Page 4: ...inaires s parer le rail sup rieur du rail inf rieur 1 Retrait des filtres 2 ES Operaciones preliminares separar la estructura superior de la estructura inferior 1 Extracci n de filtros 2 IT Operazioni...

Page 5: ...nstalaci n La altura de montaje recomendada desde la superficie de cocci n hasta el fondo de la campana se indica con una A en el dibujo siguiente Se recomienda instalar la campana en este rango para...

Page 6: ...llation 4 and ceiling installation without chimney extension and upper trestle 5 FR Installation au plafond 3 installation sur faux plafond 4 et installation au plafond sans exten sion de chemin e et...

Page 7: ...7 1 4 8 mm x4 4 3 1 2 2 x8 1 H1 EN Trestle 6 and extension 7 assembly FR Montage support de fixation 6 et rallonge 7 ES Montaje estructura 6 y prolongaci n 7 IT Montaggio traliccio 6 e prolunga 7 6 7...

Page 8: ...hout upper trestle and without extension 8 FR Installation sur plafond sans support de fixation sup rieur et sans rallonge 8 ES Instalaci n en techo sin estructura superior y sin prolongaci n 8 IT Ins...

Page 9: ...y 11 FR Montage clapet anti retour 9 tube d aspiration 10 assemblage conduit d vacuation 11 ES Montaje de v lvula de no retorno 9 tubo de aspiraci n 10 montaje de chimenea 11 IT Montaggio valvola di n...

Page 10: ...O F F I T T O 3 V3 x4 12 13 14 EN Ceiling configuration 12 False ceiling configuration 13 14 FR Installation sur plafond 12 Installation sur faux plafond 13 14 ES Configuraci n en techo 12 Configurac...

Page 11: ...et fixation conduit d vacuation rallonge 16 ES Instalaci n c mara motor 15 conexi n el ctrica y fijaci n de chimenea prolongaci n 16 IT Installazione camera motore 15 collegamento elettrico e fissagg...

Page 12: ...nstallation au plafond sans rallonge H ni treillis T 17 18 ES Instalaci n en techo sin extensi n H y enrejado T 17 18 IT Installazione su soffitto senza prolunga H e traliccio T 17 18 EN Mandatory saf...

Page 13: ...tion d poser le panneau 19 enlever les filtres m talliques 20 Montage du filtre en option 22 ES Procedimiento de desmontaje quite el panel 19 quite los filtros met licos 20 Montaje del filtro opcional...

Page 14: ...uipment e g Safety shoes and adopt prudent and proper conduct The installation kit screws and plugs supplied with the hood is only to be used on masonry walls in case of installation on walls of a dif...

Page 15: ...irectly to per sons things and pets as a consequence of failing to comply with the safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the e...

Page 16: ...alified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical specifications are exhibited on the labels located inside the...

Page 17: ...Set maximum speed 3 Press keys for 5 seconds All keys flash Within 5 seconds press and hold the key for 5 seconds If all the keys light up and are steady the setting procedure has been successful MAX...

Page 18: ...hour taking care not to bend them Do not use corrosive acid or alkaline detergents Rinse them well and wait for them to be completely dry before reassembling them Washing in a dishwasher is permitted...

Page 19: ...otte NE doit PAS tre install e la remettre dans son emballage d origine et contacter le Revendeur Apr s son installation aucune r clamation ne sera accept e pour des d fauts esth tiques Pendant l inst...

Page 20: ...s entre des murs des pla fonds ou dans des greniers des vides sanitaires ou des garages AVERTISSEMENT AFIN DE R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES MISES EN GARDE P...

Page 21: ...us pourriez vous br ler c NE PAS UTILISER D EAU y compris des torchons ou des serviettes mouill s une violente explo sion de vapeur en r sulterait d Utiliser un extincteur UNIQUEMENT si 1 Vous savez q...

Page 22: ...s dans le cas contraire contacter le Centre d Assistance le plus proche Pour le raccordement lectrique contacter un personnel qualifi Le raccordement doit tre effectu conform ment aux dispositions de...

Page 23: ...ive LED rouge teinte si Vous appuyez une autre fois sur la touche TIMER Si vous appuyez sur la touche ON OFF Si le bo tier de commande est totalement inactif avant de contac ter le service d Assistanc...

Page 24: ...c est dire un D chet d ri vant d quipements lectriques et lectroniques et par cons quent il ne doit pas tre jet dans la poubelle non s lective c est dire avec les d chets urbains mixtes mais il doit t...

Page 25: ...instalada no se aceptar ninguna recla maci n por defectos est ticos Durante la instalaci n utilice siempre equipos de protecci n personal ej calzado de protecci n contra accidentes y adopte comportami...

Page 26: ...ocal Para reducir el riesgo de incendio y extraer el aire adecuadamente aseg rese de canalizar el aire al exterior No ventile el aire de escape hacia otras zonas a trav s de paredes o techos o hacia t...

Page 27: ...A Antes de realizar cualquier tipo de limpieza o de mantenimiento desconecte el equipo desenchuf ndolo o usando el interruptor general No use la campana con las manos mojadas o los pies descalzos Cont...

Page 28: ...ambiente exterior a trav s del tubo de descarga Para ello el racor de salida de la campana debe conectarse mediante un tubo a una salida externa El tubo de salida debe tener un di metro no inferior a...

Page 29: ...andos est totalmente inactivo antes de contactar con el servicio de asistencia t cnica corte temporalmente unos 5 la alimentaci n el ctrica al electrodom stico en lo posible a trav s del interruptor g...

Page 30: ...on los residuos urbanos mixtos sino que se tiene que eliminar por separado siguiendo las operaciones correspondientes para su reciclaje o someterse a un tratamiento espec fico para eliminar de forma s...

Page 31: ...i di pro tezione personale es scarpe antiinfortunistiche ed adottare comportamenti prudenti e corretti Il kit di fissaggio viti e tasselli fornito con la cappa utilizzabile unicamente su pareti in mur...

Page 32: ...di pulizia sullo stesso Il Costruttore declina ogni responsabilit per eventuali danni che possano direttamente o in direttamente essere causati a persone cose ed animali domestici conseguenti alla man...

Page 33: ...pa possono essere calde se utilizzate insieme con apparecchi di cottura Non effettuare operazioni di pulizia quando parti del la cappa sono ancora calde Se la pulizia non condotta secondo le modalit e...

Page 34: ...appa E necessario isolare la tubazione se passa attraverso ambienti freddi Per impedire ritorni d aria dall esterno una valvola di non ritorno presente in presenza di motori con 500CFM o superiori CAP...

Page 35: ...ecnica togliere temporaneamente circa 5 l alimentazione elettrica all elettrodomestico possibilmente agen do sull interruttore generale per ripristinare il normale funzionamento Se questo accorgimento...

Page 36: ...ndifferenziata cio insieme ai rifiuti urbani misti ma deve essere gestito separatamente cos da essere sottoposto ad ap posite operazioni per il suo riutilizzo oppure a uno specifico trattamento per ri...

Page 37: ...37 NOTE NOTES...

Page 38: ...38 NOTE NOTES...

Page 39: ...39 NOTE NOTES...

Page 40: ...Code 110033050 ED 01 2022 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com...

Reviews: