FALMEC Eros FPERO36U5SS-R Instruction Booklet Download Page 9

9

ENGLISH

In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for 
grounding, blue for neutral and brown for the live. The plug must be con-
nected to an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, or any 

other device that ensures disconnection from the electrical mains, with an 
opening gap of the contacts that enables total disconnection in overvoltage 
category III conditions.

  Said disconnection devices must be provided in the mains power supply in 

compliance with installation regulations.

The cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety 
regulations.

FUMES DISCHARGE

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside 
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a 
pipe, to an external output.

The outlet pipe must have:
•  a diameter not less than that of the hood fitting.
•  a slight slope downwards (drop) in the horizontal sections to prevent conden-

sation from flowing back into the motor.

•  the minimum required number of bends.
•  the minimum required length to avoid vibrations and reduce the suction per-

formance of the hood.

  You are required to insulate the pipes if it passes through cold environments.
  In the presence of motors with 500 CFM or higher, a check valve is present to 

prevent external air flowing back.

HOOD WITH INTERNAL RECIRCULATION (FILTERING)

In this model, the air passes through the charcoal filters to be 
purified and recycled in the environment.

Ensure that the active carbon filters are assembled into the 
hood, if not, install them as indicated in the assembly instruc-
tions. 

In this version the check valve must not be assembled: remove it if it is 
on the air outlet fitting of the motor.

ASSEMBLY INSTRUCTIONS

Intended only for qualified personnel

The hood can be installed in various configurations.

The generic assembly steps apply to all installations; for each case, 

follow the specific steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?

Switch on the hood at least one minute before starting to cook to direct fumes 
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours 
and odours. By means of the Timer function, it is possible to set auto switch-off 
function which will allow the hood to turn off automatically after 15 minutes of 
operation.

WHICH SPEED IS TO BE SELECTED?

1st speed: 

maintains the circulation of clean air with low electricity consump-

tion.

2nd speed:

 normal conditions of use.

3rd speed: 

presence of strong odours and vapours.

4th speed:

 rapid disposal of odours and vapours.

WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?

The metal filters must be cleaned every 30 hours of operation. 
The active carbon filters must be replaced every 3-4 months, depending on the 
use of the hood.
For further details refer to the

 

“MAINTENANCE”

 

section.

ELECTRONIC PUSHBUTTON PANEL

Motor ON/OFF

Upon start-up, the speed is that stored at the previous operation.

Increase speed from 1 to 4

Speed 4 is only active for a few 
minutes, then speed 3 activates.

The speeds are indicated by the 
LEDs on the keys:

 Speed 1

 Speed 2

 Speed 3

 Speed 4 

("+" LED flashing)

Reduce speed from 4 to 1

 

Light on/off

TIMER

 (red LED flashing)

Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER key ( ) is pressed again.
- The ON/OFF key ( ) is pressed.

FILTER ALARM

 (red LED steady on with ( ) off )

Anti-grease filter maintenance after approximately 30 hours of op-
eration.
Press ( ) the meter for 3 seconds to reset.

If the pushbutton panel is completely inactive, before contacting 

the Technical assistance service, disconnect power temporarily to 

the appliance (about 5“), possibly by acting on the main switch, to restore 

normal operation.

If this measure has no effect, contact the Technical assistance service.

 MAINTENANCE

Before cleaning or carrying out maintenance operations, discon-

nect the equipment by removing the plug or switching off the 

main switch.

Do not use detergents containing abrasive, acidic or corrosive substances 

or abrasive cloths.

Regular maintenance guarantees proper operation and performance over time.
Special attention is to be paid to the 

metal anti-grease filters

 : frequent clean-

ing of the filters and their supports ensures that no flammable grease is accu-
mulated.

Summary of Contents for Eros FPERO36U5SS-R

Page 1: ...INSTRUCTIONS BOOKLET falmec com M A D E I N V I T TO R I O V E N E TO T V I TA LY EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI Eros FPERO30U5SS...

Page 2: ...8 60mm 12 305mm EROS UNDERCABINET 30 FPERO30U5SS 120V 60HZ 280W 52lb 24 kg EN tool required FR outil requis ES herramienta requerida IT Attrezzi necessari EN cable length 5 0ft 1 5m FR longueur de c b...

Page 3: ...laci n La altura de montaje recomendada desde la superficie de cocci n hasta el fondo de la campana se indica con una A en el dibujo siguiente Se recomienda instalar la campana en este rango para opti...

Page 4: ...4 A B C 1 2 2 Y 8 207mm A 4 5 16 8 mm V1 x2 2 A 3 Y 8 207mm 1 A 24 35 610 mm 890 mm RECOMMENDED FOR OPTIMAL PERFORMANCE...

Page 5: ...piration 3 position les filtres m talliques 4 ES Montaje del tubo de aspiraci n 3 posici n los filtros met licos 4 IT Montaggio tubo d aspirazione 3 posizionamento filtri metallici 4 EN Mandatory safe...

Page 6: ...rbon actif standard reti rer les filtres m talliques 5 monter les filtres au charbon actif 6 ES Montaje del filtro de carb n activo de serie quite los filtros met licos 5 monte los fil tros de carb n...

Page 7: ...cal seal danger Do not install the hood outdoors and do not expose it to atmospheric elements rain wind etc ELECTRICAL SAFETY The electrical system to which the hood is to be connected must be in acco...

Page 8: ...open unattended flames under the hood Do not prepare food over an open flame under the hood Never use the hood without the metal anti grease filters in this case grease and dirt will deposit in the eq...

Page 9: ...ired installation OPERATION WHEN TO TURN ON THE HOOD Switch on the hood at least one minute before starting to cook to direct fumes and vapours towards the suction surface After cooking leave the hood...

Page 10: ...w consumption LED spot lights with an extremely long life span under normal use conditions Should the LED spotlight need to be replaced proceed as shown in the figure 12V 3 1 2 DISPOSAL AFTER END OF U...

Page 11: ...ique et de tenue m canique Ne pas installer la hotte l ext rieur et ne pas l expo ser des agents atmosph riques pluie vent etc S CURIT LECTRIQUE Le circuit lectrique auquel est reli e la hotte doit tr...

Page 12: ...ffectu s par l utilisateur ne doivent pas tre effectu s par des enfants sans surveillance MISES EN GARDE POUR L UTILISATION ET LE NETTOYAGE Avant de proc der toute op ration de nettoyage ou d entretie...

Page 13: ...nte de la hotte Il est n cessaire d isoler la tuyauterie si elle passe par des endroits non chauf f s Pour emp cher les retours d air de l ext rieur un clapet de non retour est ins tall en pr sence de...

Page 14: ...L air pur est ainsi renvoy dans la pi ce Les filtres au charbon actif doivent tre remplac s en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des filtres au...

Page 15: ...la campana en exteriores ni la exponga a agentes atmosf ricos lluvia viento etc SEGURIDAD EL CTRICA La instalaci n el ctrica a la cual se conecta la campana debe respetar las normas co rrespondientes...

Page 16: ...MPIEZA Antes de realizar cualquier tipo de limpieza o de mantenimiento desconecte el equipo desenchuf ndolo o usando el interruptor gene ral No use la campana con las manos mojadas o los pies descalzo...

Page 17: ...re desde el exterior hay una v lvula de no retorno en presencia de motores con 500 CFM o superiores CAMPANA DE RECIRCULACI N INTERNA FILTRANTE En esta versi n el aire pasa a trav s de los filtros de c...

Page 18: ...er sustituidos cada 3 4 meses en condiciones de uso normal Para sustituir los filtro de carb n activo consulte las instrucciones de montaje ILUMINACI N La campana cuenta con iluminaci n mediante bombi...

Page 19: ...me di sicu rezza del Paese di utilizzo deve essere inoltre conforme alle normative Europee sull antidistur bo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quella...

Page 20: ...rasso grasso e sporco in questo caso si depositereb bero nell apparecchio compromettendone il funzio namento Parti accessibili della cappa possono essere calde se utilizzate insieme con apparecchi di...

Page 21: ...ri muoverla se presente sul raccordo di uscita aria del motore ISTRUZIONI DI MONTAGGIO parte riservata solo a personale qualificato La cappa ha la possibilit di essere installata in varie configurazi...

Page 22: ...SMALTIMENTO A FINE VITA Il simbolo del cestino barrato riportato sull apparecchiatura in suo pos sesso indica che il prodotto un RAEE cio un Rifiuto derivante dal le Apparecchiature Elettriche ed Elet...

Page 23: ...23 NOTE NOTES...

Page 24: ...Cod 110033036 ED 01 2021 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com...