It is imperative that this instructions booklet is 

kept together with the equipment for any future 

consultation.

If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 
After the stainless steel hood has been installed, it 

will need to be cleaned to remove any residues re-

maining from the protective coating as well as any 

grease and oil stains which, if not removed, can cause 

irreversible damage to the hood surface. To properly 

clean the unit, the manufacturer recommends using 

the supplied moist wipes, which are also available 

sold separately. 
Insist on original spare parts.

State of California Proposition 65 Warning 

 

(US only) 

WARNING 

This product contains chemicals known to the State 

of California to cause cancer and birth defects or oth-

er reproductive harm. 

For more information go to www.P65Warnings.ca.gov

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the age 

of 8 and by persons with reduced physical, sensory 

and mental abilities, or with no experience or knowl-

edge, as long as they do so under supervision or after 

having received relative instructions regarding safe 

use of the equipment and understanding of the dan-

gers connected to it.

Children are not to play with the equipment. Clean-

ing and maintenance by the user must not be carried 

out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching off the 

main switch.

Do not use the hood with wet hands or bare feet.
Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 
The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

3lb 5oz  (1.5 Kg).

Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.
Do not leave open, unattended flames under the 

hood.
Do not prepare food over an open flame under the 

hood.
Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.
Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.
Do not carry out any cleaning operations when parts 

of the hood are still hot.
There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.
Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room where 

the fumes are discharged is well-ventilated, in 

compliance with the local regulations.

  INSTALLATION

   Intended only for qualified personnel

Before installing the hood, carefully read the section  'SAFETY 

INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-

ment and the lowest part of the hood is indicated in the installation in-

structions. 

Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(Intended only for qualified personnel)

Disconnect the equipment from electrical mains power supply be-

fore carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions of law 

in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the techni-

cal specifications located inside the hood);

•  the power supply plug and cable do not come into contact with tempera-

tures exceeding 158°F (70 °C);

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.

Summary of Contents for Eros FPERO36U5SS-R

Page 1: ...INSTRUCTIONS BOOKLET falmec com M A D E I N V I T TO R I O V E N E TO T V I TA LY EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI Eros FPERO30U5SS...

Page 2: ...8 60mm 12 305mm EROS UNDERCABINET 30 FPERO30U5SS 120V 60HZ 280W 52lb 24 kg EN tool required FR outil requis ES herramienta requerida IT Attrezzi necessari EN cable length 5 0ft 1 5m FR longueur de c b...

Page 3: ...laci n La altura de montaje recomendada desde la superficie de cocci n hasta el fondo de la campana se indica con una A en el dibujo siguiente Se recomienda instalar la campana en este rango para opti...

Page 4: ...4 A B C 1 2 2 Y 8 207mm A 4 5 16 8 mm V1 x2 2 A 3 Y 8 207mm 1 A 24 35 610 mm 890 mm RECOMMENDED FOR OPTIMAL PERFORMANCE...

Page 5: ...piration 3 position les filtres m talliques 4 ES Montaje del tubo de aspiraci n 3 posici n los filtros met licos 4 IT Montaggio tubo d aspirazione 3 posizionamento filtri metallici 4 EN Mandatory safe...

Page 6: ...rbon actif standard reti rer les filtres m talliques 5 monter les filtres au charbon actif 6 ES Montaje del filtro de carb n activo de serie quite los filtros met licos 5 monte los fil tros de carb n...

Page 7: ...cal seal danger Do not install the hood outdoors and do not expose it to atmospheric elements rain wind etc ELECTRICAL SAFETY The electrical system to which the hood is to be connected must be in acco...

Page 8: ...open unattended flames under the hood Do not prepare food over an open flame under the hood Never use the hood without the metal anti grease filters in this case grease and dirt will deposit in the eq...

Page 9: ...ired installation OPERATION WHEN TO TURN ON THE HOOD Switch on the hood at least one minute before starting to cook to direct fumes and vapours towards the suction surface After cooking leave the hood...

Page 10: ...w consumption LED spot lights with an extremely long life span under normal use conditions Should the LED spotlight need to be replaced proceed as shown in the figure 12V 3 1 2 DISPOSAL AFTER END OF U...

Page 11: ...ique et de tenue m canique Ne pas installer la hotte l ext rieur et ne pas l expo ser des agents atmosph riques pluie vent etc S CURIT LECTRIQUE Le circuit lectrique auquel est reli e la hotte doit tr...

Page 12: ...ffectu s par l utilisateur ne doivent pas tre effectu s par des enfants sans surveillance MISES EN GARDE POUR L UTILISATION ET LE NETTOYAGE Avant de proc der toute op ration de nettoyage ou d entretie...

Page 13: ...nte de la hotte Il est n cessaire d isoler la tuyauterie si elle passe par des endroits non chauf f s Pour emp cher les retours d air de l ext rieur un clapet de non retour est ins tall en pr sence de...

Page 14: ...L air pur est ainsi renvoy dans la pi ce Les filtres au charbon actif doivent tre remplac s en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des filtres au...

Page 15: ...la campana en exteriores ni la exponga a agentes atmosf ricos lluvia viento etc SEGURIDAD EL CTRICA La instalaci n el ctrica a la cual se conecta la campana debe respetar las normas co rrespondientes...

Page 16: ...MPIEZA Antes de realizar cualquier tipo de limpieza o de mantenimiento desconecte el equipo desenchuf ndolo o usando el interruptor gene ral No use la campana con las manos mojadas o los pies descalzo...

Page 17: ...re desde el exterior hay una v lvula de no retorno en presencia de motores con 500 CFM o superiores CAMPANA DE RECIRCULACI N INTERNA FILTRANTE En esta versi n el aire pasa a trav s de los filtros de c...

Page 18: ...er sustituidos cada 3 4 meses en condiciones de uso normal Para sustituir los filtro de carb n activo consulte las instrucciones de montaje ILUMINACI N La campana cuenta con iluminaci n mediante bombi...

Page 19: ...me di sicu rezza del Paese di utilizzo deve essere inoltre conforme alle normative Europee sull antidistur bo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quella...

Page 20: ...rasso grasso e sporco in questo caso si depositereb bero nell apparecchio compromettendone il funzio namento Parti accessibili della cappa possono essere calde se utilizzate insieme con apparecchi di...

Page 21: ...ri muoverla se presente sul raccordo di uscita aria del motore ISTRUZIONI DI MONTAGGIO parte riservata solo a personale qualificato La cappa ha la possibilit di essere installata in varie configurazi...

Page 22: ...SMALTIMENTO A FINE VITA Il simbolo del cestino barrato riportato sull apparecchiatura in suo pos sesso indica che il prodotto un RAEE cio un Rifiuto derivante dal le Apparecchiature Elettriche ed Elet...

Page 23: ...23 NOTE NOTES...

Page 24: ...Cod 110033036 ED 01 2021 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com...

Reviews: