WARNING

Be sure to read, understand, and follow all instructions and warnings in this manual. 

Any misuse could result in serious injury or death. 

3.0  Application

 

3.1 Purpose: 

The FallTech® Removable Concrete Anchor is designed to be placed into a pre-drilled hole in minimum 3,000 psi fully cured    

 

concrete.  The anchors described in this manual have specific installation requirements relative to concrete thickness and edge distance.    

 

The overall structure to which the anchor is attached must be capable of supporting 3,600 lbs.  The anchors may be installed overhead,    

 

vertically, or horizontally.  Installation of the anchor below the full body harness (FBH) dorsal D-ring requires the use of a PFAS designed    

 

for extended free fall scenarios. When properly installed, the anchors may be used as part of a PFAS, restraint or work positioning system.   

 

See Section 5.6 for specific installation requirements.

 

3.2 Personal Fall Arrest System:

 A PFAS is typically composed of an anchorage and a FBH, with an energy absorbing connecting device,    

 

i.e., a EAL, an SRD, or a Fall Arrester Connecting Subsystem (FACSS), attached to the dorsal D-ring of properly fitted and adjusted FBH. All    

 

uses and applications of a FBH with this equipment requires the FBH to be properly fitted and adjusted to the user. Failure to properly 

 

fit the FBH to the user could result in serious injury or death.  

  

 

3.3 Application Limits:

 When using the anchor discussed in this manual care should be taken to ensure that the units have been installed   

 

using the correct tools, that the hole depth and diameter conform with the installation instructions, and that the substrate is of strength 

 

enough to support the intended loads. In addition, care should be taken when reusing the anchor in a previously drilled hole and/or if the   

 

anchor becomes lodged in place and becomes difficult to remove. IN ALL CASES, A COMPETENT PERSON SHALL INSPECT FOR PROPER 

 

INSTALLATION AND REMOVAL OF THE REMOVABLE CONCRETE ANCHOR.

 

 

3.4 Approved Applications:

 Below are applications for which the Removeable Concrete Anchor are specifically suited. This list is not  

 

 

all-inclusive, but is intended to anticipate the most common applications in which this product may be used.  See Figure 2.

  

3.4.1 Personal Fall Arrest:

 The 7443 is designed to be used as single person anchor point with a maximum tensile strength of    

 

 

3,600 lbs. Use for the attachment of Horizontal Lifeline systems is prohibited. Use for the purpose of suspension is prohibited.

  

3.4.2 Work Positioning:

 The FallTech® Removable Concrete Anchor may be used as a component of a work positioning system    

 

 

to support the user at a work position. Work positioning systems typically include an FBH with integrated side D-rings, a body 

 

 

belt, and a positioning lanyard. A back up PFAS is required when the user is exposed to a free fall of 2 ft (1.8 m) or more.

  

3.4.3 Restraint:

 The FallTech® Removable Concrete Anchor may be used as a component of a restraint system to prevent the    

 

 

user from reaching a fall hazard. Restraint systems typically include a full body harness containing a body belt and a lanyard or 

  restraint 

line. 

MANC36 Rev A

042921

4

2.0  Description

 

The FallTech® Removable Concrete Anchor described in this manual is designed to provide a temporary anchorage for personal fall 

 

arrest, work positioning, and restraint systems. All of the anchors in this manual are configured to fit into a pre-drilled hole in concrete in    

 

such a manner that they become wedged in place during installation and capable of supporting the intended loads of the aforementioned  

 

systems. Upon job completion the anchors are mechanically designed to be removed for reuse.

Figure 1 - About FallTech® Removable Concrete Anchor

A

Ring

F

Stop Ferrules

B

Labels

G

Anchor Cable

C

Washer

H

Easy Button

D

Retractor Spring

I

Chocks

E

Retractor Handle

J

Wedge

A

B

C

D

E

F

H

G

I

J

Summary of Contents for 7443

Page 1: ...CA 90221 USA Tel 800 719 4619 Fax 323 752 5613 This manual is intended to meet the Manufacturer s Instructions as required by the American National Standards Institute ANSI Z359 and should be used as...

Page 2: ...Maintenance Service and Storage 7 0 Inspection 8 0 Labels 9 0 Specifications 3 4 4 5 6 8 8 10 10 MANC36 Rev A 042921 2 For purposes of this manual the FallTech Removable Concrete Anchor in all iterati...

Page 3: ...eath due to falls because of increased fall arrest forces placed on the user s body In addition the onset of suspension trauma after a fall even may be accelerated for heavy users The user of the equi...

Page 4: ...ecomes difficult to remove IN ALL CASES A COMPETENT PERSON SHALL INSPECT FOR PROPER INSTALLATION AND REMOVAL OF THE REMOVABLE CONCRETE ANCHOR 3 4 Approved Applications Below are applications for which...

Page 5: ...n a way that would produce a condition of loading on the gate D Never attach to a object in a manner whereby the gate of the snap hook or carabiner would be prevented from fully closing and locking Al...

Page 6: ...quipment must determine the MRFC for units discussed in this manual to ensure adequate clearance exists in the fall path Variables discussed in this manual include the height of the anchor point relat...

Page 7: ...anual may be re inserted in a previously used anchor insertion hole that passes pre use inspection The previously used hole must still retain the same depth diameter and functional properties as descr...

Page 8: ...or death 6 3 Storage Store in a clean dry and chemical free environment and kept out of direct sunlight 6 0 Maintenance Service and Storage 7 0 Inspection 7 1 Pre Use Inspection Please review the Pre...

Page 9: ...rial _________________________ Date of Manufacture _________________________ INSPECTION DATE INSPECTOR COMMENTS PASS FAIL CORRECTIVE ACTION NEEDED APPROVED BY 7 4 Inspection Document Record inspection...

Page 10: ...Concrete Anchor Model Application Dimensions Minimum Tensile Strength and Material Maximum User Capacity Image 7443 Expansion Wedge Anchor with Swaged Loop Cured Concrete 3 000 psi Min 11 3 4 Drilled...

Reviews: