Door and Frame Preparation: 

A. Choose degree of door opening.
B. Drill per appropriate fastener, using chart above.

2

¹⁄₂

"

(64 mm)

2³⁄₈

"

(60 mm)

6

³⁄₄

"

(171 mm)

A

CL

Hinge

     

¹¹⁄₁₆

"

17 

mm

B

⁵⁄₁₆

"

mm

1³⁄₄

"

44 

mm

1¹¹⁄₁₆

"

43 

mm

3³⁄₈

"

86 

mm

1¹⁄₁₆

"

27 

mm

2¹⁄₈

"

54 

mm

CL

Hinge

Top View

Right Hand Door Illustrated. Same dimensions 

apply for Left Hand Door measured from center 

line of hinge.

Opening

A

B

Up To 100°

8

C\v

" (222 mm)

10

B\,

" (270 mm)

101° – 130°

7

Z\v

" (184 mm)

9

Z\,

" (232 mm)

131° – 150°

6

Z\v

" (159 mm)

8

Z\,

" (206 mm)

151° – 180°

5

Z\v

" (133 mm)

7

Z\,

" (181 mm)

Front View

Fasteners

Use

Description

Drill/Tap

Closer Body

#14 Wood

1/8" Drill

1/4-20

#7 Drill, 1/4-20 Tap

Arm Shoe

#14 Wood

1/8" Drill

1/4-20

#7 Drill, 1/4-20 Tap

Thru-bolt

Wood/Metal

3/8" Drill

Fifth Hole 

Spacer

#14 Wood

1/8" Drill

1/4-20

#7 Drill, 1/4-20 Tap

Arm 

Attachment

Arm 

Attachment 

Lock Washer

Cover Plug

Cover Screw

Closer mounted on push 

side of door  

(opposite of hinge side).

 CAUTION 

Improper installation or regulation may result in personal 

injury or property damage. Follow all instructions 

carefully. For questions, call Falcon at number below.

L=Latch Speed Valve

S/D=Main Speed Valve

B=Backcheck Valve

Spring Power Adjustment

SC71

L=Latch Speed Valve

S=Main Speed Valve

S/D=Delay Action Valve

Spring Power Adjustment

SC71 DEL

SC71 Series Closer

Installation Instructions
Forged Arm Models, SC71 (1-6 Adj.)

"P" Valve, Normally Closed

 

(877) 671-7011